VNE Vacuum Tube Compression Amplifier
HAZELRIGG INDUSTRIES
12
OPERATION
Input
Since the input cable will be carrying high quality audio, it is important that a well-shielded cable
is used. You should strive to minimize the number connectors, patch jacks, switches, etc. between
the source and the VNE input.
Output
The output of the VNE is line level, transformer balanced. Note that vacuum tube equipment is
more sensitive to load impedance than solid state units. The VNE design was optimized for
feeding a balanced bridging input (20k ohms or greater). When feeding a 600 ohm load, there
may be a slight degradation of some of the specifications. In modern studio equipment, bridging
line inputs are universal. If the device being fed by the VNE has an input termination switch, that
switch should be in the “off” position.
The VNE can feed balanced or unbalanced inputs with no need for any modification in output
wiring. Either pin 2 or 3 can be grounded, although pin 2 is normally used as the ”hot” and pin 3
grounded in unbalanced configurations.