config flow_meter
Parameters
profile_id <value 1-255>
−
Enter an integer used to identify the access
profile that will be configured with this command. This value is assigned to
the access profile when it is created with the
create access_profile
command. The profile ID sets the relative priority for the profile and
specifies an index number that will identify the access profile being created
with this command. Priority is set relative to other profiles where the lowest
profile ID has the highest priority. The user may enter a profile ID number
between 1 – 255, yet, remember only 9 access profiles can be created on
the Switch.
add access_id <value 1-65535>
−
Adds an additional rule to the above
specified access profile. The value is used to index the rule created. For
information on number of rules that can be created for a given port, lease
see the introduction to this chapter.
rate<value 0-999936>
−
Enter a desired bandwidth of the ingress traffic that
you want to limit.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example usage:
To configure the ACL flow meter on the Switch:
DES-3500:admin#config flow_meter profile_id 1 access_id 1 rate 1000 rate_exceed drop
Command: config flow_meter profile_id 1 access_id 1 rate 1000 rate_exceed drop
Warning! Flow_meter will lose effect if bandwidth control is enabled
Success.
DES-3500:admin#
show flow_meter
Purpose
Used to view the current state of ACL flow meter on the Switch.
Syntax
show flow_meter
Description The
show flow_meter
command is used view the current state of ACL flow
meter on the Switch.
Parameters None.
Restrictions None.
Example usage: