xStack Storage Management Center Software User’s Guide
87
6.2.3 Controller Details (Controller Tab)
The Controller tab in the System Administration View displays status information about the
controller (see Figure 6-7). If your xStack Storage system is equipped with dual controllers,
the Controller tab label appears as either “Controller 0” or “Controller 1”, depending on
which controller you selected in the Main View. Table 6-1 lists the information appears on
the Controller tab.
Table 6-1. Controller Tab Information
Item
Description
Status
OK or Failed
State
Single-controller systems appear as “
Standalone”, while dual-controller systems appear as
“
Bound”, “Survivor” or “Unable to Bind”.
Health
Healthy or Unhealthy
Battery State
OK or Failed
Controller Type
ATX-based systems (DSN-1000/2000/3000 series) or SFF (for DSN-5000 Series systems)
Controller Slot Id
Single-controller systems will always show Slot 0, while dual-controller systems will show Slot
0 or 1 depending on which controller was selected in the Main View
Date/Time
The current system date and time
Persistence Data State
Only used for diagnostic purposes; this item should normally appear as: "Unchanged "
Drive Slot Count
The number of drive slots that are defined for the controller
Ethernet Data Port Count
The number of iSCSI data ports that are available on the controller
Buffer Memory Dimm Count
The number of memory modules that are installed for Buffer Memory
Buffer Memory Size
The amount of Buffer Memory that is detected
System Memory Dimm Count
The number of memory modules that are installed for System Memory
System Memory Size
The amount of System Memory that is detected
NAND Memory Size
The amount of NAND Memory that is detected
Serial Number
The serial number of the controller
Software Current Version
The version of the software that is running on the controller
Alternate Software Version
The alternate version of software that is stored in the inactive partition
Mfg Board Revision
The manufacturing revision of the controller assembly
Mfg Product Id
The manufacturing product number
Summary of Contents for DSN-5410-10 - xStack Storage Area Network Array Hard...
Page 9: ...xStack Storage Management Center Software User s Guide ix This Page Left Intentionally Blank ...
Page 10: ......
Page 90: ...80 Chapter 5 Managing Physical Storage This Page Left Intentionally Blank ...
Page 110: ...100 Chapter 6 System Administration Figure 6 18 Advanced Settings Tab ...
Page 132: ...122 Chapter 8 Performing System Actions THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 136: ...126 Chapter 9 Best Practices This Page Left Intentionally Blank ...
Page 144: ...134 Appendix A Menu Summary THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 148: ...138 Appendix B Factory Default Settings THIS PAGE LEFT INTENTIONALLY BLANK ...