Unpacking and Installation
Contact your dealer for correction of any LED problems before
proceeding.
The actual component tests immediately follow the LED tests.
A normal (no fault) result is signaled by a series of three cycles
of sequential flashing of the three LEDs, followed by a
quiescent state with all three LEDs dark.
If the self-test routine traps any component error, then
following the LED tests the self-test will halt and the LED’s will
continuously signal the error according to the following table.
In the event of any such error signal, contact your dealer for
correction of the faulty unit.
LED Name
Faulty
LPT1
LPT2
COM
Component
off
off
on/steady
COM error
off
off
flashing
Flash ID error
off
on/steady
off
LPT2 error
off
on/steady
on/steady
LAN Controller error
off
on/steady
flashing
LAN Memory error
off
flashing
off
Parallel-2 Controller error
off
flashing
on/steady
EEPROM error
off
flashing
flashing
Flash Protected
on/steady
off
off
LPT1 error
on/steady
off
on/steady
Timer INT error
on/steady
off
flashing
LAN IO Base error
on/steady
on/steady
off
RAM error