background image

xStack

®

 

DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Hardware Installation Guide 

 

 

2

routers, switches and other networking devices. The dual speed ports use standard twisted-pair cabling and are ideal 

for segmenting networks into small, connected sub networks for superior performance. Each 10/100 port can support 

up to 200 Mbps of throughput in full-duplex mode.  
In addition, the Switch has  2 SFP combo ports. These two-gigabit combo ports are ideal for connecting to a server or 

network backbone. This stackable Switch enables the network to use some  of the mo st demanding multimedia and 

imaging a pplications concurrently with  other user  applications without creat ing bottlene cks. The b uilt-in co nsole 

interface can  be used to  configure the  Switch's settings  for prio rity queuing, VLANs, and  port trun k group s, port  

monitoring, and port speed. 

Features 

  IEEE 802.3 10BASE-T compliant 

  IEEE 802.3u 100BASE-TX compliant 

  IEEE 802.1p Priority Queues 

  IEEE 802.3x flow control in full duplex mode 

  IEEE 802.3ad Link Aggregation Control Protocol 

support. 

  IEEE 802.1X Port-based and MAC-based Access 

Control 

  IEEE 802.1Q VLAN 

  IEEE 802.1D Spanning Tree, IEEE 802.1W Rapid 

Spanning Tree and IEEE 802.1s Multiple Spanning 

Tree support 

  Access Control List (ACL) support 

  Single IP Management support 

  Access Authentication Control utilizing TACACS, 

XTACACS and  

  Dual Image Firmware 

  Simple Network Time Protocol support 

  MAC Notification support 

  Asymmetric VLAN support 

  System and Port Utilization support 

  System Log Support 

  Support port-based enable and disable  

  Address table: Supports up to 16K MAC addresses 

per device 

  Supports a packet buffer of up to 1 Mbyte 

  Supports Port-based VLAN Groups  

  Port Trunking with flexible load distribution and fail-

over function 

  IGMP Snooping support 

 SNMP  support 

  Secure Sockets Layer (SSL) and Secure Shell 

(SSH) support 

 Port  Mirroring support 

  MIB support for: 

  RFC1213 MIB II 

 RFC14 93 Bridge 

  RFC1907 SNMPv2 MIB 

  RFC1757, 2819 RMON 

 RFC20 21 RMONv2 

  RFC1643, 2358, 2665 Ether-like MIB 

  RFC2233, 2863 Interface MIB 

 Private  MIB 

  RFC2674 for 802.1p 

  RFC2618 RADIUS Authentication Client 

  RFC2620 RADIUS Accounting Client 

  RFC2925 Ping & Traceroute 

 IEEE  802.1X MIB 

  RS-232 DCE console port for Switch management 

  Provides parallel LED display for port status such as 

link/act, speed, etc. 

  High performance switching engine performs forwarding and filtering at full wire speed, maximum 14, 881 packets/sec on 

each 10Mbps Ethernet port, and maximum 148,810 packet/sec on 100Mbps Fast Ethernet port. 

  Full- and half-duplex for both 10Mbps and 100Mbps connections. Full duplex allows the switch port to simultaneously 

transmit and receive data. It only works with connections to full-duplex-capable end stations and switches. Connections to a 

hub must take place at half-duplex 

  Support broadcast storm filteringF 

  Non-blocking store and forward switching scheme capability to support rate adaptation and protocol conversion 

  Supports by-port Egress/Ingress rate control. 

  Supports IP-MAC Port Binding. 

  Efficient self-learning and address recognition mechanism enables forwarding rate at wire speed 

  Supports STP Loopback Detection 

  Safeguard Engine Support

 

Summary of Contents for DES-3528 - xStack Switch - Stackable

Page 1: ... Hardware Installation Guide ProductModel xStack DES 3528 DES 3552 Series Layer2ManagedStackable Fast Ethernet Switch Release 2 61 ...

Page 2: ...poration is strictly forbidden Trademarks used in this text D L ink and the D LINK logo are trademarks of D Link Corporation Microsoft and Windows are registered trademarks of Microsoft Corporation Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products D Link Corporation disclaims any proprietary interest in trad...

Page 3: ... a domestic environment this produ ct may cause ra dio interference in which case the user ma y be required to take adequate measures Warnung Dies ist ein Produkt der Klasse A Im Wohnbereich kann dieses Produkt Funkstoerungen verursachen In diesem Fall kann vom Benutzer verlangt werden angemessene Massnahmen zu ergreifen Precaución Este es un producto de Clase A En un entorno doméstico puede causa...

Page 4: ...9 Gigabit Combo Ports 10 Installation 11 Package Contents 11 Before You Connect to the Network 11 Installing the Switch without the Rack 12 Installing the Switch in a Rack 12 Mounting the Switch in a Standard 19 Rack 13 Power On AC Power 13 Power Failure AC Power 13 Connecting DC Power to the DES 3528DC 14 Connecting the Switch 15 Switch to End Node 15 Switch to Hub or Switch 15 Connecting To Netw...

Page 5: ...ged Stackable Fast Ethernet Switch Hardware Installation Guide iv Introduction 23 Login to Web Manager 23 Web based User Interface 24 Web Pages 25 Technical Specifications 27 Cable Lengths 34 Glossary 35 Warranties and Tech Support Information 38 ...

Page 6: ...ro gram nam es and co mmands For example use the copy command Boldface Typewriter Font Indicates commands and responses to prom pts that must be typed exa ctly as pri nted in the manual Initial capital letter Indicates a wind ow nam e Name s of keys on the keyboard have initial capitals Fo r example Click Enter Italics Indicates a windo w name or a field Also ca n indicate a variables or para mete...

Page 7: ... and never operate the product in a wet enviro nment If the system gets wet see the appro priate se ction in your trouble shooting guide or co ntact your trained service provider Do n ot pu sh any obje cts into the op enings of your system Doing so can cause fi re or electri c sho ck by shorting out interior components Use the product only with approved equipment Allow the product to cool before r...

Page 8: ...iple sources of power disconnect power from the system by unplugging all power cables from the power supplies Move products with care ensure that all caste rs and or stabilizers are firmly connected to the system Avoid sudden stops and uneven surfaces General Precautions for Rack Mountable Products Observe the following preca utions for rack stabilit y and safe ty Also refer to the rack installati...

Page 9: ... the safety ground cable is omitted or disconnected Protecting Against Electrostatic Discharge Static electri city can h arm delicate compon ents i nside y our system To prevent static damag e discharge stati c electricity from your body before you touch any of the electronic components such as the microprocessor You can do so by periodically touching an unpainted metal surface on the chassis You ...

Page 10: ...Ethernet utilizing the same packet structure format and support for full duplex flow control and manag ement objects but with a t enfold increase in theoretical throu ghput over 100Mb ps Fast Ethernet and a one hundred fold increase over 10Mbps Ethernet Since it is compati ble with all 10Mbp s and 100Mbps Ethernet enviro nments Gigabit Ethernet provides a strai ghtforward upgrade without wasting a...

Page 11: ... System and Port Utilization support System Log Support Support port based enable and disable Address table Supports up to 16K MAC addresses per device Supports a packet buffer of up to 1 Mbyte Supports Port based VLAN Groups Port Trunking with flexible load distribution and fail over function IGMP Snooping support SNMP support Secure Sockets Layer SSL and Secure Shell SSH support Port Mirroring s...

Page 12: ... duplex IEEE 802 3af compliant DES 3528P DES 3552P only Auto MDI X MDI II c ross over support SFP Transceivers Supported DEM 310GT 1000BASE LX DEM 311GT 1000BASE SX DEM 314GT 1000BASE LHX DEM 315GT 1000BASE ZX DEM 312GT2 1000BASE SX DEM 210 Single Mode 100BASE FX DEM 211 Multi Mode 100BASE FX WDM Transceiver Supported DEM 330T TX 1550 RX 1310nm up to 10km Single Mode DEM 330R TX 1310 RX 1550nm up ...

Page 13: ... 1 Front Panel View of the DES 3528 switch DES 3528P Twenty four 10 100Mbps BASE T ports Two Combo 1000BASE T SFP ports located to the right Two 1000BASE T ports located to the rear One female DCE RS 232 DB 9 console port One PoE Select Button LEDs for Power Console RPS MS Link PoE Link Act Speed for each port Figure 1 2 Front Panel View of the DES 3528P switch DES 3528DC Twenty four 10 100Mbps BA...

Page 14: ...One female DCE RS 232 DB 9 console port One PoE Select Button LEDs for Power Console RPS MS Link PoE Link Act Speed for each port Figure 1 5 Front Panel View of the DES 3552P switch LED Indicators The Switch suppo rts LED indicators for Power Con sole RPS Master on DE S 3528P and DES 3552P this LED is for MS and Port LEDs The following shows the LED indicators for the DES 3528 DES 3552 switch seri...

Page 15: ...ice is the stacking master Light off Not the Stacking Master Stacking ID Green Capable 1 8 The Box ID is assigned either by the user static mode or by the system automatic mode When the box becomes a primary master the 7 segments work bi functionally The box ID and H indicate the primary Master and the display on other switches will be shown in turn That is boxID H boxID H Mode Select Button DES 3...

Page 16: ...r link at any of the ports Blinking Green When there is reception or transmission i e Activity Act of data occurring at a 1000Mbps connected port Solid Amber When there is a se cure 10 100M bps Fast Ethern et conne ction or link at any of the ports Blinking Amber When there is reception or transmission i e Activity Act of data occurring at a 10 100Mbps Fast Etherne t conn ected port Light off No l...

Page 17: ...and 52 1000BASE T RS 232 DCE Diagnostic port console port an AC power connector and an outlet for an optional external RPS Figure 1 14 Rear panel view of the DES 3552P The AC p ower connector is a stan dard three pronged connector that su pports the p ower cord Plug in the femal e connector of the provide d power cord i nto this socket and the male side of the cord into a power outlet The Switch a...

Page 18: ...des a heat ven t The system fa ns are use d to dissi pate heat Do not block these openings on either side of the Switch Leave at least 6 inches of space at the rear and sides of the Switch for proper ventilation Be reminde d that without proper heat dissipation and air circulation system components might overheat which could lead to system failure Figure 1 17 Side panels of the DES 3552 DES 3528P ...

Page 19: ...ed and SFP ports optional See the di agram below to view the t wo SFP port modules bei ng plug ged i nto the Switch Please n ote that although the se t wo front pa nel module s can be u sed simultaneously At the same time only one copper port or one SFP port can link up for each combo po rt The SFP port will always have the highest priority Figure 1 19 Inserting the SFP modules into the DES 3528 D...

Page 20: ...ffect its performance Please follow these guidelines for setting up the Switch Install the Switch o n a sturdy level surface that c an su pport at least 6 6 lbs 3 kg of weight for DES 3528 DES 3528DC at lea st 13 2 lb s 6 kg of weigh t for DES 3552 DES 3528P at least 1 5 4 lbs 7 kg of weight for DES 3552P Do not place heavy objects on the Switch The power outlet should be within 1 82 meters 6 feet...

Page 21: ...of the device Allow enough ventilation space between the Switch and any other objects in the vicinity Figure 2 1 Preparing the Switch for installation on a desktop or shelf Installing the Switch in a Rack The Switch can be mounted in a standard 19 rack Use the following diagrams to guide you Figure 2 2 Fasten mounting brackets to the Switch Fasten the mounting brackets to the Switch using the scre...

Page 22: ... than one component out of the ra ck on its slide assemblies at one time The weight of more than one extended component could cause the rack to tip over and may result in injury Figure 2 3 Installing the Switch in a rack Power On AC Power Plug one end of the AC p ower cord into the powe r connector of the Switch a nd the other end into the local po wer source outlet After the Switch is powered on ...

Page 23: ...e negative and positive contacts on the wiring assembly The negative pole connects to the 48V contact The positive pole connects to the 48V Return contact If available an earth ground may be connected to the center contact post 3 Tighten the contact screws to secure the connection NOTE Use a minimum 18 gauge AWG wire All powe r co nnection wi ring sh ould conform to the rules a nd regulatio ns in ...

Page 24: ...a a twisted pair Category 3 4 or 5 UTP STP cable T he end n ode should be connected to any of the ports of the Switch Figure 3 1 The Switch connected to an end node The Link Act LEDs for each UTP port will light green or amber when the link is valid A blinking LED indicates packet activity on that port Switch to Hub or Switch These connections can be accomplished in a number of ways using a normal...

Page 25: ... SFP combo ports are ideal for linking to a network backbone or server The copper ports operate at a speed of 1000 100 or 10Mbps in full or half duplex mode The fiber optic ports can operate at 100Mbps or 1000Mbps in full duplex mode Connections to the Gigabit Ethernet ports are made using fiber optic cable or Category 5E copper cable depending on the type of port A valid connection is indicated w...

Page 26: ...ds to requests with MIB objects stored in the database The SNMP agent updates the MIB objects to generate statistics and counters Connecting the Console Port RS 232 DCE The Switch p rovides an RS 232 serial port that enables a co nnection to a computer or terminal for monitoring an d configuring the Switch This port is a female DB 9 connector impleme nted as a data co mmunications equipm ent DCE c...

Page 27: ... ext section f or mo re inf ormation on setting up use r acco unts See t he DES 3528 DES 3552 Switch Series CLI Reference Guide on the do cumentation CD for a li st of all commands and additional information on using the CLI 13 When you h ave co mpleted you r tasks exit the session with t he log out co mmand or close th e em ulator program 14 Make sure the terminal or PC you are using to make this...

Page 28: ...erved Username PassWord DES 3528 admin Figure 4 2 Command Prompt NOTE The first user automatically gets Administrator level privileges It is recommended to create at least one Admin level user account for the Switch Password Protection The Switch does not have a default user name and password One of the first tasks when settings up the Switch is to create user accounts Once logge d in using a pred...

Page 29: ...ned in a Manage ment Informatio n Base M IB which pro vides a sta ndard p resentation of the information controlled by the on board SNMP agent SNMP defines both the format of the MIB specifications and the protocol used to access this information over the network The Switch supports SNMP versions 1 2c and 3 You can specify which version of SNMP you want to use to monitor and control the Switch T h...

Page 30: ...etwork management software In addition to the s tandard MIB II the Switch also supports its own proprietary enterprise MIB as an extended Ma nagement Information Base Specifying the MIB Object Identifier may also retrieve the proprietary MIB MIB values can be either read only or read write IP Address Assignment Each Switch must be assigned its own IP Address which is used for communication with an...

Page 31: ...d the y s repre sent the corresponding subnet mask Alternatively you can en ter config ipif System ipaddress xxx xxx xxx xxx z Where the x s rep resent the IP address to be assigned to the IP interface named System and the z represents the corresponding number of subnets in CIDR notation The IP interface named System on the Switch can be assigned an IP address and subnet mask and then be used to c...

Page 32: ... are diffe rent ways to acce ss the same internal switching software and configure it Thus all se ttings encountered in Web based management are the sam e as those found in the console program Login to Web Manager To begin m anaging the Switch sim ply run the bro wser you ha ve installed o n your co mputer and p oint it to the IP address you have defined for the dev ice Th e URL in the address bar...

Page 33: ...b Manager page Area Function Area 1 Select the folder or wi ndow to be displ ayed The folder ico ns can be opene d to display the hyper linked window buttons and subfolders contained within them Cli ck the D Link logo to go t o the D Link Website Area 2 Presents a graphical near real time image of the f ront panel of the Switch T his area displays the Switch s port s and expa nsion modul es sho wi...

Page 34: ...ngs Multicast Static FDB Settings MAC Notification Settings MAC Address Aging Time Settings MAC Address Table ARP FDB Table L2 M ulticast Control IGMP Sn ooping IGMP Snooping Settings IGMP Snoopin g Rate Limit Settings IGMP Snoopin g Static Gro up Settings IGMP Route r Port IGMP Snooping G roup IGMP Snooping Forwarding Table IGMP Snooping Counter CPU Filter L3 Control Packet Settings MLD Snooping ...

Page 35: ...Settings DHCP R elay Option 61 Settings DHCP Server DHCP Server Global Settings DHCP Server Excl ude Address Settings DHCp Server Pool Settings DH CP Server M anual Binding DHCP Server Dynamic Binding DH CP Conflict IP DHCP v6 Relay DHCPv6 Relay Global Settings DH CPv6 Relay Settings DH CP Local Relay Settings DNS D NS Relay DNS Relay Global Settings DNS Relay Static Settings PPPoE Circuit ID Inse...

Page 36: ...HX DEM 315GT 1000BASE ZX DEM 312GT2 1000BASE SX DEM 210 Single Mode 100BASE FX DEM 211 Multi Mode 100BASE FX WDM Transceivers Supported DEM 330T TX 1550 RX 1310nm up to 10km Single Mode DEM 330R TX 1310 RX 1550nm up to 10km Single Mode DEM 331T TX 1550 RX 1310nm up to 40km Single Mode DEM 331R TX 1310 RX 1550nm up to 40km Single Mode Standards IEEE802 3 Data Transfer Rates Ethernet Fast Ethernet G...

Page 37: ...Power Input 36 75 V DC 0 6A Max Output 12V 1 2A Max Internal universal power supply DES 3528 DES 3552 Provides one connector on the re ar panel to in stall an optio nal external RPS DPS 200 to enhan ce the reliability When the internal po wer fails the optional ext ernal RPS will take over all the power imm ediately and automatically DES 3528P DES 3552P Provides one connector on the re ar panel to...

Page 38: ...re 40 70 C Humidity Operation Relative Humidity 5 95 non condensing Storage Relative Humidity 5 95 non condensing Dimensions DES 3528 DES 3528DC 441 W x 210 D x 44 H mm DES 3552 DES 3528P 441 W x 310 D x 44 H mm DES 3552P 441 W x 370 D x 44 H mm Weight DES 3528 2 51kg 5 53lbs DES 3528DC 2 52kg 5 55lbs DES 3552 4 09kg 9 01lbs DES 3528P 5 42kg 11 94lbs DES 3552P 6 52kg 14 37lbs EMI CE Class A FCC Cl...

Page 39: ...Transmission Method Store and forward Packet Buffer 1 MB per device Packet Filtering Forward Rate 14 881 pps 10M port 148 810 pps 100M port 1 488 100 pps 1 Gbps port Port Functions Feature Detailed Description Console Port DCE RS 232 DB 9 for out of band configuration of the software features 10 100BaseT ports Compliant to following standards IEEE 802 3 compliance IEEE 802 3u compliance Support Ha...

Page 40: ...p to 10km Single Mode DEM 331T TX 1550 RX 1310nm up to 40km Single Mode DEM 331R TX 1310 RX 1550nm up to 40km Single Mode Compliant to following standards IEEE 802 3z compliance IEEE 802 3u compliance 1000BASE T ports 1000BASE T ports compliant to following standards IEEE 802 3 compliance IEEE 802 3u compliance IEEE 802 3ab compliance Support Full Duplex operations IEEE 802 3x Flow Control support...

Page 41: ...s Usage Max power used by PD 0 Default 0 44 to 12 95W 1 Optional 0 44 to 3 84W 2 Optional 3 84 to 6 49W 3 Optional 6 49 to 12 95W 4 Reserved 12 95W to 30W 6 PSE should be provide the power following the classification below Class Usage Max power used by PD 0 Default 15 4W 1 Optional 4 0W 2 Optional 7 0W 3 Optional 15 4W 4 Reserved 15 4W 30W 7 DES 3528P 52P follow the standard PSE pin out standard ...

Page 42: ...tive Receive signal 2 Receive Negation Receive signal 3 Transmit Positive Transmit signal 4 5 6 Transmit Negation Transmit signal 7 8 FE Port PSE Pinout Assignment for Power Pairs alternative A MDI X PIN Signal Description 1 Negative Vport Negative power signal 2 Negative Vport Negative power signal 3 Positive Vport Positive power signal 4 5 6 Positive Vport Positive power signal 7 8 33 ...

Page 43: ...aximum cable lengths Standard Media Type Maximum Distance SFP 1000BASE LX Single mode fiber module 1000BASE SX Multi mode fiber module 1000BASE LHX Single mode fiber module 1000BASE ZX Single mode fiber module 10km 550m 40km 80km 1000BASE T Category 5e UTP Cable 100m 100BASE TX Category 5 and Category 5e UTP Cable 100 Mbps 100m 10BASE T Category 3 4 5 and 5e UTP Cable 10 Mbps 100m ...

Page 44: ...work segments BOOTP The BOOTP prot ocol allows you to automa tically map an IP addre ss to a given MAC address each time a device is started In addition the protocol can assign the subnet mask and default gateway to a device bridge A device that interconnects local or remote networks no matter what higher level protocols are involved Bridges form a single logical network centralizing network admin...

Page 45: ...e over data transmission should the other fail See also main port and standby port RJ 45 Standard 8 wire connectors for IEEE 802 3 10BASE T networks RMON Remote Monitoring A subset of SNMP MIB II that allows monitoring and management capabilities by addressing up to ten different groups of information RPS Redundant Power System A device that provides a backup source of power when connected to the ...

Page 46: ...on one device to send a datagram to an application program on another device VLAN Virtual LAN A grou p of location an d topology i ndependent dev ices that co mmunicate as if they are on a common physical LAN VLT Virtual LAN Trunk A Switch to Switch link which carries traffic for all the VLANs on each Switch VT100 A type of terminal that uses ASCII characters VT100 screens have a text based appear...

Page 47: ...ation pertaining to the product and in that case the product is being sold As Is without any warranty whatsoever including without limitation the Warranty as described herein notwithstanding anything stated herein to the contrary Submitting A Claim The customer shall return the product to the original purchase point based on its return policy In case the return policy period has expired and the pr...

Page 48: ...ms Inc Other trademarks or registered trademarks are the property of their respective owners Copyright Statement No part of this publication or documentation accompanying this product may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without permission from D Link Corporation D Link Systems Inc as stipulated by the United ...

Page 49: ...Registration Register your D Link product online at http support dlink com register Product registration is entirely voluntary and failure to complete or return this form will not diminish your warranty rights ...

Page 50: ...e warranty period on this product U S and Canadian customers can contact D Link technical support through our website or by phone Tech Support for customers within the United States D Link Technical Support over the Telephone USA 877 DLINK 55 877 354 6555 D Link Technical Support over the Internet http support dlink com Tech Support for customers within Canada D Link Technical Support over the Tel...

Page 51: ...2 00pm 0 05ppm peak 0 045ppm off peak Times Internet http www dlink co uk ftp ftp dlink co uk Technische Unterstützung Deutschland Web http www dlink de Telefon 49 0 1805 2787 0 14 pro Minute Zeiten Mo Fr 08 30 17 30 Uhr Österreich Web http www dlink at Telefon 43 0 820 480084 0 116 pro Minute Zeiten Mo Fr 08 30 17 30 Uhr Schweiz Web http www dlink ch Telefon 41 0 848 331100 0 08 CHF pro Minute Ze...

Page 52: ...0 501 2007 0 15per minuut Tech Support for customers within Belgium www dlink be 070 66 06 40 0 175per minuut spitsuren 0 0875per minuut daluren Technische ondereuning voor klanten in Luxemburg www dlink be 32 70 66 06 40 Asistencia Técnica Asistencia Técnica Telefónica de D Link 34 902 30 45 45 0 067 min De Lunes a Viernes de 9 00 a 19 00 http www dlink es Supporto tecnico Supporto Tecnico dal lu...

Page 53: ...9 00 do 17 00 Volání je zpoplatněno dle příslušných tarifů Vašeho operátora Technikai Támogatás Tel 06 1 461 3001 Fax 06 1 461 3004 Land Line 14 99 HUG min Mobile 49 99 HUF min email support dlink hu URL http www dlink hu Teknisk Support D Link Teknisk Support over Internett http www dlink no D Link Teknisk telefonsupport 820 00 755 Hverdager 08 00 20 00 Teknisk Support D Link teknisk support over...

Page 54: ...Κεφαλληνίας 64 11251 Αθήνα Τηλ 210 86 11 114 Δευτέρα Παρασκευή 09 00 17 00 Φαξ 210 8611114 http www dlink gr support Assistência Técnica Assistência Técnica da D Link na Internet http www dlink pt e mail soporte dlink es Teknisk Support D Link Teknisk Support via Internet http www dlink se D Link Teknisk Support via telefon 0900 100 77 00 Vardagar 08 00 20 00 ...

Page 55: ...k biz hr Tehnična podpora Zahvaljujemo se vam ker ste izbrali D Link proizvod Za vse nadaljnje informacije podporo ter navodila za uporabo prosimo obiščite D Link ovo spletno stran www dlink eu www dlink biz sl Suport tehnic Vă mulţumim pentru alegerea produselor D Link Pentru mai multe informaţii suport şi manuale ale produselor vă rugăm să vizitaţi site ul D Link www dlink eu www dlink ro ...

Page 56: ...day to Wednesday 9 30AM to 6 30PM Thursdays 9 30AM to 2 00 PM E mail Support sa dlink me com D Link Middle East Dubai U A E Plot No S31102 Jebel Ali Free Zone South P O Box 18224 Dubai U A E Tel 971 4 8809022 Fax 971 4 8809066 8809069 Technical Support 971 4 8809033 General Inquiries info me dlink me com Tech Support support me dlink me com Egypt 1 Makram Ebeid Street City Lights Building Nasrcity...

Page 57: ...ne 212 663 72 73 24 Email support na dlink me com Lebanon RMA center Dbayeh Lebanon PO Box 901589 Tel 961 4 54 49 71 Ext 14 Fax 961 4 54 49 71 Ext 12 Email taoun dlink me com Bahrain Technical Support 973 1 3332904 Kuwait Technical Support 965 22453939 965 22453949 Türkiye Merkez İrtibat Ofisi Ayazağa Maslak yolu Erdebil Cevahir İş Merkezi No 5 A Ayazağa Maslak İstanbul Tel 90 212 2895659 Ücretsiz...

Page 58: ...исимости 169 БЦ XXI Век Тел 375 17 218 13 65 E mail minsk dlink ru Казахстан 050008 г Алматы ул Курмангазы дом 143 уг Муканова Тел факс 7 727 378 55 90 E mail almaty dlink ru Узбекистан 100015 г Ташкент ул Нукусская 89 Тел Факс 998 71 120 3770 150 2646 E mail tashkent dlink ru Армения 0038 г Ереван ул Абеляна 6 1 4 этаж Тел Факс 374 10 398 667 E mail erevan dlink ru Грузия 0162 г Тбилиси проспект ...

Page 59: ...entes teléfonos de D Link PAIS NUMERO Argentina 0800 12235465 Chile 800 835465 ó 02 5941520 Colombia 01800 9525465 Costa Rica 0800 0521478 Ecuador 1800 035465 El Salvador 800 6335 Guatemala 1800 8350255 México 01800 1233201 Panamá 011 008000525465 Perú 0800 00968 Venezuela 0800 1005767 Soporte Técnico de D Link a través de Internet Horario de atención Soporte Técnico en www dlinkla com e mail sopo...

Page 60: ...br Acionar Garantia para 4 ou mais equipamentos Telefones São Paulo 11 2755 6950 GO 4052 1850 Ligação local Nordeste 0800 7024104 Demais Estados 4062 1850 Ligação local Apenas Modems ADSL Garantia diferenciada vendida pela internet Agilidade e tranquilidade para suas atividades Conheça http garantiapremium dlink com br Atendimento disponível das 9h as 21h de segunda a sexta feira e aos sábados das...

Page 61: ...方式與D Link台灣 地區技術支援工程師聯絡 D Link 免付費技術諮詢專線 0800 002 615 服務時間 週一至週五 早上9 00到晚上9 00 不含周六 日及國定假日 網 站 http www dlink com tw 電子郵件 dssqa_service dlink com tw 如果您是台灣地區以外的用戶 請參考D Link網站全球各地 分公司的聯絡資訊以取得相關支援服務 產品保固期限 台灣區維修據點查詢 請參考以下網頁說明 http www dlink com tw 產品維修 使用者可直接送至全省聯強直營維修站或請洽您的原購買經銷商 ...

Page 62: ...okumentasi pengguna dapat diperoleh pada situs web D Link Dukungan Teknis untuk pelanggan Dukungan Teknis D Link melalui telepon Tel 62 21 5731610 Dukungan Teknis D Link melalui Internet Email support dlink co id Website http support dlink co id ...

Page 63: ...Technical Support この度は弊社製品をお買い上げいただき 誠にありがとうご ざいます 下記弊社 Web サイトからユーザ登録及び新製品登録を 行っていただき ダウンロードサービスにて サポート情報 ファームウェア ユーザマニュアルを ダウンロードすることができます ディーリンクジャパン Web サイト URL http www dlink jp com ...

Page 64: ...技术支持 办公地址 北京市东城区北三环东路 36 号 环球贸易中心 B 座 26F 02 05 室 邮编 100013 技术支持中心电话 8008296688 028 66052968 技术支持中心传真 028 85176948 各地维修中心地址请登陆官方网站查询 网址 http www dlink com cn 办公时间 周一到周五 早09 00到晚18 00 ...

Page 65: ... site 1 employee 2 9 10 49 50 99 100 499 500 999 1000 or more 3 What network protocol s does your organization use XNS IPX TCP IP DECnet Others_____________________________ 4 What network operating system s does your organization use D Link LANsmart Novell NetWare NetWare Lite SCO Unix Xenix PC NFS 3Com 3 Open Cisco Network Banyan Vines DECnet Pathwork Windows NT Windows 98 Windows 2000 ME Windows...

Page 66: ......

Reviews: