Setting Up the Device 

Before You Start 

Local Cable Service 

You will need to establish an account with your local cable operator in order to access the Internet 
with this modem. They will assist you in setting up the modem to operate on their network.  

Then for your modem to communicate with the cable service, you will first need to be able to identify the cable 

modem. On the cable modem find the make and model (i.e. D-Link DCM-200). The Cable Media Access Control 
(CMAC) address is a unique number that is used for the purpose of identifying the modem on the network. The 

CMAC address is found on the rear panel of the modem. Serial Number is found on the bottom of the cable 

modem. You may be required to provide the following information to your cable service operator. For convenient 

reference you can write the Modem Make and Model, CMAC address, and Serial Number in the space provided 

below. 

 

Modem Make and Model 

______________________________________ 

 

CMAC address

 _______________________________________________ 

 

Serial Number

 ________________________________________________ 

 

Minimum System Requirements 

The capabilities and limitations of your computer equipment and configuration can affect the overall performance 
of your Internet connection. 

The DCM-200 USB/Ethernet Cable Modem is designed to work with the following operating systems: 

♦ 

Windows 95/98 

(Only support Ethernet function)

 

The following operating systems can support both USB/Ethernet function 

♦ 

Windows XP 

♦ 

Windows 2000  

♦ 

Windows ME (Millennium Edition) 

♦ 

98 SE (Second Edition)  

♦ 

Active Ethernet Port or NIC installed 

♦ 

TCP/IP installed on all devices 

All computers not using the USB interface that are connected to the modem must have either an active Ethernet 

interface or network interface card (NIC) installed. You will need to enable TCP/IP protocol on each computer. 
TCP/IP should already be installed in any computer with an active Ethernet interface. The instructions for 

installing TCP/IP vary depending on the type of system used. These instructions will be included with the NIC or 

discussed in the computer’s manual if your PC comes equipped with an Ethernet port. Your cable operator may 

have additional instructions for TCP/IP configuration that must be followed. 

Summary of Contents for DCM-200

Page 1: ...DCM 200 DOCSIS 1 0 DOCSIS 1 1 Upgradable USB Ethernet Cable Modem Manual Third Edition Dec 2001 6DCM200 04 Made in Taiwan RECYCLABLE...

Page 2: ...____________________ 3 Local Cable Service 3 Minimum System Requirements 3 Connection Architecture 4 Identifying External Components _________________________________________________________________ 5...

Page 3: ...face and a standard RJ 45 port for a 10BASE T connection to a computer or computer network When properly configured these connections allow simultaneous data transfers to an existing IP data network o...

Page 4: ..._________________ Serial Number ________________________________________________ Minimum System Requirements The capabilities and limitations of your computer equipment and configuration can affect th...

Page 5: ...out of the splitter can be connected to your TV or set top box and the cable modem NOTE 1 If your cable TV company does not provide a splitter or you chose to buy your own make sure you get one with s...

Page 6: ...ction is achieved using a length of cable TV wire supplied by your cable company during installation USB Port Connect this port on the DCM 200 directly to your PC Understanding Indicators Before setti...

Page 7: ...ce The DCM 200 USB Ethernet Cable Modem can only work with either the Ethernet port or the USB port at one time They CANNOT work simultaneously If you connect both the USB port and Ethernet port to di...

Page 8: ...ple near a bathtub toilet or sink Placement Do not place this product on an unstable surface The product may fall causing serious injury to a child or adult as well as serious damage to the product Di...

Page 9: ...coming from the central office Report the problem to your cable operator if the cable connection appears to be OK LED indicators appear to be normal but Internet access can not be established Try to e...

Page 10: ...mV QPSK Error Correction Reed Solomon Interface CPE Interface 10BASE T Ethernet RJ45 RF Interface F Type Female 75 ohm connector USB Interface USB 1 0 compliant Type B receptacle LEDs Power Link Act S...

Page 11: ...ants that during the Warranty Period the magnetic media on which D Link delivers the Software will be free of physical defects D Link s sole obligation shall be to replace the non conforming Software...

Page 12: ...IS REPAIR REPLACEMENT OR REFUND OF THE DEFECTIVE OR NON CONFORMING PRODUCT GOVERNING LAW This 5 Year Warranty shall be governed by the laws of the state of California Some states do not allow exclusi...

Reviews: