background image

Technical Data

2/12

KA 34-ACB / KA 54-ACB

English

English

Observe maximum pressure load of the chain!
Maximum  pressure  load  of  the  chain  is  not 
automatically identical with maximum pressure force 
of the drive!

Pressure load diagram

KA 54-BSY+

KA 34-BSY+

100

200

300

400

500

600

700

800

500

400

300

200

100

0

max. Load (N)

Stroke / (mm)

Safety notes

Safety extra low voltage 24 V DC!

Do not connect directly to the mains supply!
-   Connection has to be carried out only by an

   authorized electrical specialist

-   Danger of violent pressure in handaccessible area
-   Keep away people from the operating area of the

   drive

-   Keep away children from the control
-   Observe pressure load diagram of the chain!
-   Use only in dry rooms
-   Only for inside mounting.

   Use rain detector with danger of rain
   (e.g. at domelights or roof windows)

-   This product may not be operated without the

   covering stoppers,  which are delivered with
   bracket sets

-   Just use unchanged original D+H parts
-   Observe mounting instructions of bracket set!

Observe enclosed r

  

ed safety slip!

Performance features

-   ACB (Advanced Communication Bus) bus interface

   with ModBus protocol for the connection to
   compatible D+H control panels or direct integration
   into building management systems, for example

-   Microprocessor controlled synchro electronics

   BSY + for a precise synchronous run of up to
   8 drives

-   Individually programmable (via software SCS)
-   SHEV-high speed function (fast-running 

   feature in OPEN-direction)

-   Protection system for the main closing edge
-   Locking relief after closing

Drive unit with 2,5 m silicone cable. Dependent on 
the  type  of  window,  different  bracket  sets  are 
available separately.

Extent of supply

Intended use

-   Chain drive for electric opening and closing of

   windows and flaps in the facade and roof area

-   Operating voltage 24 V DC stabilized
-   Useable for smoke ventilation as well as daily 

   natural ventilation

-   Only for inside mounting

WARNING

Read all safety warnings, instructions, illustrations 
and specifications provided with this product.
Failure to follow all instructions listed below may 
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future 
reference.

* Programmable with software SCS

Opening and Closing Ranges

Type

KA 34-ACB

Nominal current

1 A

Nominal stroke length*

600 mm, 800 mm

Nominal locking force
Service life
Duty cycle
Housing
Ingress protection
Temp. range
Fire stability
Ambient humidity
Emission sound pressure level
Additional functions*

approx. 2000 N

>20.000 double strokes

30 % (With cycle time 10 minutes)

Aluminium powdercoated (~ RAL 9006)

IP 32 

th bracket sets)

(With covering stoppers delivered wi

-5 ... +75 °C

30 min / 300 °C

≤ 90 %, not condensing

LpA   70 dB(A)

Closing edge protection = activated (3 repetitions of stroke);

Locking relief  = activated (retraction lift max. 0,2 mm)

C3*

Nominal stroke -100 mm

300 N

7 mm/s

(16,1 mm/s)

O1*

C1*

C2*

O2*

O3*

23 mm

150 N

5 mm/s

(5 mm/s)

77 mm

150 N

5 mm/s

(5 mm/s)

23 mm

500 N

7 mm/s

(16,1 mm/s)

15 mm

500 N

7 mm/s

(16,1 mm/s)

Nominal stroke -38 mm

500 N

7 mm/s

(16,1 mm/s)

Range

Force

Speed

(SHEV high-speed)

KA 34-ACB / KA 54-ACB

3/12

99.828.64 1.3/05/20

99.828.64 1.3/05/20

ACB bus interface

ACB is used for secure communication between the 
drive  and  compatible  D+H  control  systems.  It 
enables  activation,  diagnostics  and  configuration 
with perfect position, directly from the control panel. 
In  this  process,  all  status  messages,  such  as  the 
OPEN  and  CLOSED  signals,  opening  stroke  and 
drive errors, are transmitted to the control panel.

BSY+ synchronised electronics:

A  synchronous  group  can  contain  up  to  8  drives, 
which communicate via bus. Each drive has its own 
address, configurable with SCS.
The last drive of a synchronous group is the master, 
which  controls  the  other  drives,  the  slaves. 
Differences in forces between the drives of a group 
are  balanced  by  means  of  intelligent  force  and 
position  control.  In  the  event  that  a  drive 
malfunctions, all the drives are automatically cut off.

Functional description

Summary of Contents for KA 34-ACB

Page 1: ...KA 34 ACB KA 54 ACB 99 828 64 1 3 05 20 Standard version Mirrored version Option L en Original instructions Page 2 Connection Page 8 Please order bracket sets separately ...

Page 2: ...rection Protection system for the main closing edge Locking relief after closing Drive unit with 2 5 m silicone cable Dependent on the type of window different bracket sets are available separately Extent of supply Intended use Chain drive for electric opening and closing of windows and flaps in the facade and roof area Operating voltage 24 V DC stabilized Useable for smoke ventilation as well as ...

Page 3: ...ycle time 10 minutes Aluminium powdercoated RAL 9006 IP 32 th bracket sets With covering stoppers delivered wi 5 75 C 30 min 300 C 90 not condensing LpA 70 dB A Closing edge protection activated 3 repetitions of stroke Locking relief activated retraction lift max 0 2 mm C3 Nominal stroke 100 mm 300 N 7 mm s 16 1 mm s O1 C1 C2 O2 O3 23 mm 150 N 5 mm s 5 mm s 77 mm 150 N 5 mm s 5 mm s 23 mm 500 N 7 ...

Page 4: ... 30 me 10 minutes With cycle ti Aluminium powdercoated RAL 9006 IP 32 With covering stoppers delivered with bracket sets 5 75 C 30 min 300 C 90 not condensing LpA 70 dB A Closing edge protection activated 3 repetitions of stroke Locking relief activated retraction lift max 0 2 mm C3 Nominal stroke 100 mm 500 N 7 mm s 17 2 mm s O1 C1 C2 O2 O3 23 mm 150 N 5 mm s 5 mm s 77 mm 150 N 5 mm s 5 mm s 23 m...

Page 5: ... 30 With cycle time 10 minutes Aluminium powdercoated RAL 9006 IP 32 With covering stoppers delivered with bracket sets 5 75 C 30 min 300 C 90 not condensing LpA 70 dB A Closing edge protection activated 3 repetitions of stroke Locking relief activated retraction lift max 0 2 mm C3 Nominal stroke 100 mm 800 N 7 mm s 17 2 mm s O1 C1 C2 O2 O3 23 mm 150 N 5 mm s 5 mm s 77 mm 150 N 5 mm s 5 mm s 23 mm...

Page 6: ...he forces must be rearranged by software SCS Slave 1 Mounting informations 23 mm X Main closing edge Beside closing edge Beside closing edge Closing edge protection In the CLOSE direction the drive has an active protection for the main closing edge If there is an overload in the closing range 3 and 2 the drive runs OPEN for 10 seconds then CLOSE again If after three attempts closing is not possibl...

Page 7: ... Only original D H spare parts may be used RepairistobecarriedoutexclusivelybyD H Wipe away debris or contamination with a dry soft cloth Donotusecleaningagentsorsolvents Guarantee You will get 2 years guarantee for all D H products from date of verified handing over of the system up to maximal 3 years after date of delivery when mounting and starting has been carried out by an authorized D H dist...

Page 8: ...Master 2 1 110 Ω 3 Group Mot a ACB a Mot b ACB b CPS M AM 1 2 110 Ω PinAssignment Connection BN Mot b OG ACB a GY ACB b GN BSY b YE BSY a WH Mot a WH weiss white blanc blanco BN braun brown brun marrón OG orange orange orange naranja YE gelb yellow jaune amarillo GN grün green vert verde PK rosa pink rose rosa GY grau grey gris gris 2 up to max 3 drives looped through KA 34 ACB KA 54 ACB 99 828 64...

Page 9: ... WH Mot a KA ACB GN BSY b YE BSY a GY ACB b OG ACB a BN Mot b WH Mot a KA ACB Connection Notes 1 Termination The ACB segment must be terminated with 2 resistors 110 Ω The resistors must in each case be connected at the end of the cable 2 Integrated resistor 3 Protect wire against short circuit 4 Cable according to D H table for layout of cables See instructions for use of control panel KA 34 ACB K...

Page 10: ...10 12 English KA 34 ACB KA 54 ACB 99 828 64 1 3 05 20 Connection M a s t e r Master Slave 5 cm 1 5 cm M a s t e r S l a v e 2 3 4 1 8 ...

Page 11: ...KA 34 ACB KA 54 ACB 99 828 64 1 3 05 20 350 500 600 700 800 1000 1100 1200 1300 247 5 322 5 372 5 422 5 472 5 576 5 628 5 678 5 728 5 A B 421 496 546 596 646 750 802 852 902 H Dimensions B 173 5 mm A 40 mm 5 1 m m H ...

Page 12: ...tr 28 32 22949Ammersbek Germany Tel 4940 605 65 239 Fax 4940 605 65 254 E Mail info dh partner com www dh partner com 2020 D H Mechatronic AG Ammersbek Rights to technical modifications reserved 100 Recycled paper 99 828 64 1 3 05 20 ...

Reviews: