background image

BI-BT 2

99.824.94 1.9/09/21

8/24

BI-BT 2

99.824.94 1.9/09/21

9/24

English

LED displays

Power 

(slow flashing): The BI-BT 2 is powered and 

ready for use.

Connected 

(slow flashing): The BI-BT 2 is 

connected via radio.

Connected 

(fast flashing): The BI-BT 2 is 

connected via radio and data is transferred.

The D+H Service & Configuration Suite allows the 
configuration as well as the diagnosis of µ-controlled 
D+H centrals by PC and BI-BT2 bus-interface. 
The  data  transmission  between  PC  and  BI-BT  2 
supplies by radio technology.
The range amounts up to 20 meters, depending on 
environment.
The D+H Service & Configuration Suite is fixed by 
hardware and protected against unauthorized using 
by registration code. 
There is the possibility to reset the servicetimer of 
D+H SHEV control panels independent of PC and 
only with the BI-BT 2.
Your D+H partner can load "credits" on the BI-BT 2.
With  these  "credits"  the  servicetimer  can  reset  by 
connecting the BI-BT 2 with the SHEV control panel.

The following control panels are supported:
-  CPS-B1
-  RZN 4503-T
-  RZN 4402-K (V2), RZN 4404-K (V2)
-  RZN 4408-K, RZN 4404-M, RZN 4408-M,
  RZN 4416-M
-  RZN 43xx-E with VE 520 or VE 530
as well as future products.

In  association  with  PLP  1  it´s  possible  to  program 
D+H  drives,  which  were  provided  with  PLP 
technology.
You can also configure BSY+ drives via the BI-BT 2.

Intended use

Battery operation

In  conjunction  with  the  D  +  H  control  panels,  the 
power is supplied via the respective control panel.
To configure -BSY+ drives two batteries of the type 
AA/LR6/1,5V must be inserted in the BI-BT 2 and a 
cable must be connected.

Attention!:
If the BI-BT 2 is no longer required, the cable must be 
disconnected,  otherwise  the  batteries  will  be 
discharged.

Deutsch

Servicetimer rücksetzen ohne PC

Status 1:  Rücksetzen erfolgreich und mehr als 10 „Credits“

 

 durchgängig 5 Sek. blaue LED

Status 2:  Rücksetzen erfolgreich und weniger als 10 „Credits“

 

 blinkende blaue LED 5 Sek.

Status 3:  Keine „Credits“ mehr vorhanden

 

 blaue LED blinkt 3 mal sobald das

 

BI-BT 2 mit einer Zentrale verbunden ist

Status 4:  Servicetimer ist bereits zurückgesetzt /
 

Servicetimer nicht zurückgesetzt

 

 blaue LED bleibt aus

Bitte beachten:
Beim Zurücksetzen des Servicetimers durch das BI-BT 2 wird 
die bestehende Zentralen-Parametrierung beibehalten.
Eine Änderung ist nur mit einem PC möglich!

Verbindungskabel 

zur Zentrale

RZN 44xx-K/-M

E1

D1

N-

N+

S

-

A

K

Z

D2

1

2

3

4

5

6

7

8

9

BI-BT 2

Zentrale

Detector Line

Drive

Group

Module

Connector

Service
X1

www.dh-partner.com

Zentrale

RZN 4503-T
RZN 43xx-E

mit VE 520 oder VE 530

?

Connected

Power

BI-BT

 2

Bus Interface

D+H 

Mechatronic 

AG 

• 

www

.dh-partner

.com 

• 

+49(0)40 

605 

65 
0

Servicetimer: Credits

Reset

Reset

10 Credits

10 Credits

0 Credits

1 Credits

3x

5 sec

OFF

Connected

Power

BI-BT 2

Bus Interface

D+H Mechatronic AG • www.dh-partner.com • +49(0)40 605 65 0

Servicetimer: Credits

Reset

Reset

10 Credits

10 Credits

0 Credits

1 Credits

3x

5 sec

OFF

Wenn „Credits“ von einem autorisierten D+H 
Partner auf das BI-BT 2 geladen wurden, kann der 
Servicetimer der Zentralen auch ohne PC 
zurückgesetzt werden. Das Rücksetzen erfolgt 
automatisch nach dem Anschließen des BI-BT 2 
an die Zentrale. Vor erneutem Verbinden mit einer 
anderen Zentrale muss die Verbindung für min. 5 
Sekunden getrennt werden.

VE

530

Service

USB/PC      

F3,15A

F1,25A

F0,125A

RZN 4402-K 

(V2)

RZN 4404-K 

(V2)

RZN 4408-K

RZN 4404-M
RZN 4408-M
RZN 4416-M

Hinweis:
Der Servicetimer wird mit einem Credit auf eine 
Zeit von 486 Tagen gesetzt. Ein Rücksetzen ist nur 
möglich, wenn die Restlaufzeit weniger als 440 
Tage beträgt. Wenn die Restlaufzeit größer als 440 
Tage ist, wird der Servicetimer nicht zurückgesetzt, 
und es wird auch kein Credit abgezogen.

Maintenance and cleaning

Maintenance work is only allowed when the device is in 
a de-energized condition! Inspection and maintenance 
has to be carried out according to D+H maintenance 
notes.  Only  original  D+H  spare  parts  may  be  used. 
Repair is to be carried out exclusively by D+H.
Wipe  away  debris  or  contamination  with  a  dry,  soft 
cloth.
Do not use cleaning agents or solvents.

WARNING

Read all safety warnings, instructions, illustrations 
and specifications provided with this product.
Failure to follow all instructions listed below may 
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future 
reference.

Electrical devices, accessories, batteries and packa-
ging  should  be  sorted  for  environmental-friendly 
recycling.  Do  not  dispose  electrical  devices  and 
batteries into household waste!
Only for EC countries:
According the European Guideline 2012/19/EU for 
waste  electrical  and  electronic  equipment  and  its 
implementation into national right, electrcal devices 
that are no longer usable must be collected separa-
tely  and  disposed  of  in  an  environmentally  correct 
manner.

Disposal

Declaration of Conformity

We  declare  under  our  sole  responsibility  that  the 
product  described  under  “Technical  Data”  is  in 
conformity with the following directives:

2014/30/EU, 2014/35/EU

Technical file at:
D+H Mechatronic AG, D-22949 Ammersbek

Dirk Dingfelder 

Maik Schmees

Member of the Board 

Authorized signatory, Technical Director

22.09.2021

Deutsch

English

Français

Español

Deutsch

English

Français

Español

BI-BT 2

BI-BT 2

BI-BT 2

BI-BT 2

99.824.94 1.9/09/21

99.824.94 1.9/09/21

x/24

x/24

Summary of Contents for BI-BT 2

Page 1: ...vicetimer Status Credits Reset Reset 10 Credits 10 Credits 0 Credits 1 Credits 3x 5 sec OFF BUS Interface BI BT 2 USB Dongle Verbindungskabel connection cables 30 006 22 30 006 72 30 006 23 de Origina...

Page 2: ...wie zuk nftige Produkte In Verbindung mit dem Powerline Programmer PLP1 k nnen auch D H Antriebe welche mit der PLP Technikausger stetsind programmiertwerden Das Konfigurieren von BSY Antrieben kann e...

Page 3: ...rbindungen herstellen und danach in der SCS Software das Programm Control Panel starten Connected Power BI BT 2 Bus Interface D H Mechatronic AG www dh partner com 49 0 40 605 65 0 Servicetimer Status...

Page 4: ...Panel starten Connected Power BI BT 2 Bus Interface D H Mechatronic AG www dh partner com 49 0 40 605 65 0 Servicetimer Status Credits Reset Reset 10 Credits 10 Credits 0 Credits 1 Credits 3x 5 sec OF...

Page 5: ...ed Power BI BT 2 Bus Interface D H Mechatronic AG www dh partner com 49 0 40 605 65 0 Servicetimer Status Credits Reset Reset 10 Credits 10 Credits 0 Credits 1 Credits 3x 5 sec OFF D H Service Configu...

Page 6: ...Spannungsversorgung 24 VDC 10 beliebige Polung z B Motortester oder Akkupack Verbindungskabel f r Antriebe Lieferumfang PLP 1 Steckadapter Lieferumfang PLP 1 BI BT 2 PLP 1 Zuerst alle Steckverbindunge...

Page 7: ...edits 1 Credits 3x 5 sec OFF MOTOR D a ta a D a t a b Data b BSY b Data a BSY a Bei 230 V Antrieben VORSICHT HOCHSPANNUNG LEBENSGEFAHR BI BT2 nur im Spannungsfreien Zustand anschlie en Netzspannung au...

Page 8: ...ace D H Mechatronic AG www dh partner com 49 0 40 605 65 0 Servicetimer Status Credits Reset Reset 10 Credits 10 Credits 0 Credits 1 Credits 3x 5 sec OFF Connected Power BI BT 2 Bus Interface D H Mech...

Page 9: ...the type AA LR6 1 5V must be inserted in the BI BT 2 and a cable must be connected Attention If the BI BT 2 is no longer required the cable must be disconnected otherwise the batteries will be discha...

Page 10: ...BT 2 RZN 4503 T Detector Line Drive Group Module Connector Service X1 www dh partner com Connected Power BI BT 2 Bus Interface D H Mechatronic AG www dh partner com 49 0 40 605 65 0 Servicetimer Stat...

Page 11: ...0 Servicetimer Status Credits Reset Reset 10 Credits 10 Credits 0 Credits 1 Credits 3x 5 sec OFF RZN 44xx K M E1 D1 N N S A K Z D2 1 2 3 4 5 6 7 8 9 control panel At first make all plug connections a...

Page 12: ...ted Power BI BT 2 Bus Interface D H Mechatronic AG www dh partner com 49 0 40 605 65 0 Servicetimer Status Credits Reset Reset 10 Credits 10 Credits 0 Credits 1 Credits 3x 5 sec OFF D H Service Config...

Page 13: ...supply 24 VDC 10 any polarity E g motor tester or accumulator pack adapter Scope of supply PLP 1 BI BT 2 PLP 1 At first make all plug connections and afterwards start the program PLP in the SCS Softw...

Page 14: ...dits 10 Credits 0 Credits 1 Credits 3x 5 sec OFF MOTOR D a ta a D a t a b At first make all plug connections and afterwards start the program BSY resp LDx in the SCS Software D H Service Configuration...

Page 15: ...BT 2 is connected to a control panel State 4 Service timer has already been reset Service Timer is not been reset blue LED remains Please note If the servicetimer is reset with the BI BT 2 the control...

Page 16: ...E 530 et les mod les ult rieurs Il est galement possible de programmer des moteurs D H quip s de la technologie PLP en les raccordant au programmateur Powerline PLP 1 L interface BI BT 2 permet aussi...

Page 17: ...r r alis tous les branchements lancer le programme Control Panel dans le logiciel SCS Connected Power BI BT 2 Bus Interface D H Mechatronic AG www dh partner com 49 0 40 605 65 0 Servicetimer Status C...

Page 18: ...giciel SCS Connected Power BI BT 2 Bus Interface D H Mechatronic AG www dh partner com 49 0 40 605 65 0 Servicetimer Status Credits Reset Reset 10 Credits 10 Credits 0 Credits 1 Credits 3x 5 sec OFF R...

Page 19: ...wer BI BT 2 Bus Interface D H Mechatronic AG www dh partner com 49 0 40 605 65 0 Servicetimer Status Credits Reset Reset 10 Credits 10 Credits 0 Credits 1 Credits 3x 5 sec OFF D H Service Configuratio...

Page 20: ...arit au choix par ex testeur de moteur ou pack de batterie C ble de connexion au moteur Contenu de la livraison PLP 1 Adaptateur enfichable Contenu de la livraison PLP 1 BI BT 2 PLP 1 Apr s avoir r al...

Page 21: ...s 3x 5 sec OFF MOTOR D a ta a D a t a b Data b BSY b Data a BSY a Apr s avoir r alis tous les branchements lancer le programme BSY ou LDx dans le logiciel SCS D H Service Configuration Suite Clef USB...

Page 22: ...ou VE 530 Connected Power BI BT 2 Bus Interface D H Mechatronic AG www dh partner com 49 0 40 605 65 0 Servicetimer Status Credits Reset Reset 10 Credits 10 Credits 0 Credits 1 Credits 3x 5 sec OFF C...

Page 23: ...BI BT 2 99 824 94 1 9 09 21 23 24...

Page 24: ...239 Tel 40 605 65 49 Fax 40 605 65 254 E Mail info dh partner com www dh partner com 2021 D H Mechatronic AG Ammersbek Technische nderungen vorbehalten Rights to technical modifications reserved Sous...

Reviews: