4

probes location only and may cause the heater or cooler to activate and continue 

running if there is no water flow through the system. We do not recommend putting the 

probe in a weir as it may come out of water in the event that the return pump stops, 

this will result in the probe reading the air temperature and may cause the heater to be 

switched on and stay on until water flow is restored. 
Connect a heater to the socket marked with the ‘

I

’ and sun symbol. If the heater 

has a built in thermostat, be sure to set it higher than the temperature setting on the 

controller otherwise it will fail to operate when the socket is switched on.
If being used, plug a suitable cooling device into the socket marked with the ‘

II

’ and 

snowflake symbols. If the cooling device has a built in thermostat, be sure to set it 

lower than the temperature setting on the controller to prevent it from being disabled.
Plug the Dual Heating and Cooling Controller in to suitable mains power outlet socket.

OPERATION

  

Controller is displaying snowflake symbol.

ON

 – 

The cooling power socket has been activated and will operate a device if 

plugged in to it.

FLASHING

 – 

The cooling socket is in standby mode, when the controller reaches 

the maximum set temperature it will start a 3 minute delay timer before powering the 

socket. This is to protect the cooling device from rapid cycling.

OFF

 – 

The cooling socket is not being powered and any device that is plugged in will 

be switched off. 

  

Controller is displaying the sun symbol.

ON

 – 

The heating power socket has been activated and the heating device will be 

powered on.

OFF

 – 

The heating socket is not being powered and the heating device will be 

switched off. 

 

 Controller is displaying the alarm symbol.

ON

 – 

The temperature is outside the set range, an audible alarm will also sound to 

warn of a potential problem.

OFF

 – 

The temperature is within the set range and the unit is in normal operation. 

Programming the controller

The controller has a default factory setting of 26ºC with a 0.3ºC differential on the 

heating and cooling sockets to allow the unit to be used out of the box for most 

freshwater and saltwater tropical aquariums. The setting can however be customised if 

required using the steps below.

Summary of Contents for DUAL HEATING & COOLING CONTROLLER

Page 1: ...P R O D U C T I N S T R U C T I O N M A N U A L DUAL HEATING COOLING CONTROLLER...

Page 2: ...alarm function Alarm setting range 0 5 5 C from set point Display resolution 0 1 C Accuracy 1 C NTC Sensor with 2m cable Heating control resistive load e g heater max 1600w Cooling control inductive...

Page 3: ...chiller The maximum rating for the socket is 1600w but it is important that if a refrigerant chiller is used its operating power is no more than 600w otherwise it may damage the control socket This is...

Page 4: ...er outlet socket OPERATION Controller is displaying snowflake symbol ON The cooling power socket has been activated and will operate a device if plugged in to it FLASHING The cooling socket is in stan...

Page 5: ...3 and 2 0 C Using the up and down arrows select how far below the set temperature you want the aquarium to be before the heating socket is activated Press the SET button to confirm 4 Setting the alar...

Page 6: ...unit is steady decide how much you want to offset the reading by For example if the Dual Heating and Cooling Controller is reading 26 2 C and the temperature readout you want it to match is 26 C then...

Page 7: ...thin the set heating and cooling differentials Check probe is in the correct position as per instructions and make sure it is submerged Temperature reading suddenly changes after a water change or whe...

Page 8: ...s Alarms 0 5 5 C vom Sollwert Aufl sung der Anzeige 0 1 C Messgenauigkeit 1 C NTC Sensor mit 2m Kabel Regelung der Heizung ohmsche Last z B Heizger t max 1600W Regelung der K hlung induktive Last z B...

Page 9: ...chtig funktioniert An der K hlsteckdose die mit einem II und dem Schneeflockensymbol gekennzeichnet ist kann ein Ventilator f r Verdunstungsk hlung oder ein K hlaggregat betrieben werden Die maximale...

Page 10: ...Steckdose eingeschaltet wird Wenn Sie ein geeignetes K hlger t verwenden m chten schlie en Sie es an die mit dem Symbol II und dem Schneeflockensymbol gekennzeichnete Steckdose an Wenn das K hlger t b...

Page 11: ...gen Sie die Einstellung durch Dr cken der Taste SET 2 Einstellung der K hlungsdifferenz Das blinkende Schneeflocken Symbol oben links auf dem Bildschirm zeigt an dass die Differenz f r die K hlung zwi...

Page 12: ...Duale Heiz und K hlregler ist werkseitig kalibriert und sollte keine weiteren Einstellungen ben tigen Es ist jedoch m glich die angezeigte Temperatur um 1 5 C zu ndern falls gew nscht Um diese Einste...

Page 13: ...armeinstellungen so dass sie nicht innerhalb der eingestellten Heiz und K hlparameter liegen Pr fen Sie ob die Sonde gem den Anweisungen richtig positioniert ist und ob sie eingetaucht ist Die Tempera...

Page 14: ...ge de r glage d alarme 0 5 5 C du point de consigne R solution de l affichage 0 1 C Pr cision 1 C Capteur NTC avec 2m de c ble Contr le du chauffage charge r sistive par ex r chauffeur max 1600W Contr...

Page 15: ...p rieure celle du r gulateur sinon il ne fonctionnera pas correctement La prise de refroidissement marqu e d un II et du symbole du flocon de neige peut faire fonctionner un ventilateur pour le refroi...

Page 16: ...inon il ne fonctionnera pas lorsque la prise sera allum e Si vous souhaitez utiliser un l ment de refroidissement branchez le dans la prise marqu e du symbole II et flocon de neige Si le dispositif es...

Page 17: ...Une fois cette op ration termin e confirmez en appuyant sur le bouton SET 2 R glage du diff rentiel de refroidissement Le symbole du flocon de neige doit clignoter en haut gauche de l cran pour indiq...

Page 18: ...e la temp rature du capteur soit entre 24 3 et 25 7 C ETALONNAGE Le r gulateur double fonction chauffage et refroidissement est talonn en usine et ne devrait pas n cessiter d autres r glages Il est to...

Page 19: ...ra ne des lectures erron es Modifiez l alarme afin que les r glages ne tombent pas dans les param tres de chauffage et de refroidissement d finis V rifiez que la sonde est correctement positionn e sel...

Page 20: ...TheAquariumSoln fb com theaquariumsolution FOLLOW US FOR INSPIRATION www theaquariumsolution com...

Reviews: