PRODUCT DESCRIPTION

The Dual Heating and Cooling Controller is designed to allow for the precise control of 

the temperature in both freshwater and saltwater aquariums.
The programmable controller constantly displays a real time temperature reading for 

the aquarium and uses a accurate solid state NTC (negative temperature coefficient) 

sensor, this is encased in a waterproof plastic housing allowing it to be fully submerged 

in the aquarium or sump.
Operating two independent mains output sockets the controller can power both 

suitable heating and cooling devices. One socket is dedicated to powering a heating 

element raising the temperature in the aquarium and the other for operating a cooling 

device lowering the temperature. The controller will automatically switch power to 

each socket as needed to maintain the temperature within the users settings.
Aquarium heaters up to a maximum rating of 1600w can be connected to the heating 

power socket. This socket is marked with an ‘

I

’ and a sun symbol. Heating elements 

without built in thermostats, such a s the D-D Titanium Heaters, and standard glass 

heaters with thermostats can both be used on this socket. If your heater has a built 

in thermostat this must be set higher than the temperature set on the controller, 

otherwise it will fail to operate properly.
The cooling socket, marked with an ‘

II

’ and snowflake symbol, can operate a fan for 

evaporative cooling or a refrigerant chiller. The maximum rating for the socket is 1600w 

but it is important that if a refrigerant chiller is used its operating power is no more than 

600w, otherwise it may damage the control socket. This is due to the initial starting 

power requirements for chillers as they will greatly exceed their rated operating power 

during this time.

INSTALLATION

Position the controller and power socket in a suitable location away from open water 

or splashing. Both of these components are not waterproof and may be damaged 

if they become wet. The controller can be positioned using the hook and loop self 

adhesive pads included and the power socket fixed in to place with the built-in screw 

mounting point. We recommend that the socket is not installed flat on the base of a 

cabinet near a sump in case water ingress from spills or leaks.
Position the temperature probe in an area of good water movement in the sump or 

aquarium, ideally in an place of low light to stop excess algae build up on the sensor. 

We recommend that the probe is positioned in the same area of the system as the 

heater, e.g if the heater is in the sump the probe should be upstream of the heater in 

the sump. It is important that it is kept fully submerged at all times and that it is not to 

close to a heater or chiller outlet otherwise the controller will receive false readings 

and will not operate properly. The probe should not be located where it can be drawn 

in to a pump inlet or potentially physically damaged by the aquarium inhabitance (e.g. 

Puffers, Triggerfish or Urchins). 
Please note when performing a water change it is best to disconnect the power from 

the Dual Heating and Cooling Controller as it will be reading the temperature in the 

Summary of Contents for DUAL HEATING & COOLING CONTROLLER

Page 1: ...P R O D U C T I N S T R U C T I O N M A N U A L DUAL HEATING COOLING CONTROLLER...

Page 2: ...alarm function Alarm setting range 0 5 5 C from set point Display resolution 0 1 C Accuracy 1 C NTC Sensor with 2m cable Heating control resistive load e g heater max 1600w Cooling control inductive...

Page 3: ...chiller The maximum rating for the socket is 1600w but it is important that if a refrigerant chiller is used its operating power is no more than 600w otherwise it may damage the control socket This is...

Page 4: ...er outlet socket OPERATION Controller is displaying snowflake symbol ON The cooling power socket has been activated and will operate a device if plugged in to it FLASHING The cooling socket is in stan...

Page 5: ...3 and 2 0 C Using the up and down arrows select how far below the set temperature you want the aquarium to be before the heating socket is activated Press the SET button to confirm 4 Setting the alar...

Page 6: ...unit is steady decide how much you want to offset the reading by For example if the Dual Heating and Cooling Controller is reading 26 2 C and the temperature readout you want it to match is 26 C then...

Page 7: ...thin the set heating and cooling differentials Check probe is in the correct position as per instructions and make sure it is submerged Temperature reading suddenly changes after a water change or whe...

Page 8: ...s Alarms 0 5 5 C vom Sollwert Aufl sung der Anzeige 0 1 C Messgenauigkeit 1 C NTC Sensor mit 2m Kabel Regelung der Heizung ohmsche Last z B Heizger t max 1600W Regelung der K hlung induktive Last z B...

Page 9: ...chtig funktioniert An der K hlsteckdose die mit einem II und dem Schneeflockensymbol gekennzeichnet ist kann ein Ventilator f r Verdunstungsk hlung oder ein K hlaggregat betrieben werden Die maximale...

Page 10: ...Steckdose eingeschaltet wird Wenn Sie ein geeignetes K hlger t verwenden m chten schlie en Sie es an die mit dem Symbol II und dem Schneeflockensymbol gekennzeichnete Steckdose an Wenn das K hlger t b...

Page 11: ...gen Sie die Einstellung durch Dr cken der Taste SET 2 Einstellung der K hlungsdifferenz Das blinkende Schneeflocken Symbol oben links auf dem Bildschirm zeigt an dass die Differenz f r die K hlung zwi...

Page 12: ...Duale Heiz und K hlregler ist werkseitig kalibriert und sollte keine weiteren Einstellungen ben tigen Es ist jedoch m glich die angezeigte Temperatur um 1 5 C zu ndern falls gew nscht Um diese Einste...

Page 13: ...armeinstellungen so dass sie nicht innerhalb der eingestellten Heiz und K hlparameter liegen Pr fen Sie ob die Sonde gem den Anweisungen richtig positioniert ist und ob sie eingetaucht ist Die Tempera...

Page 14: ...ge de r glage d alarme 0 5 5 C du point de consigne R solution de l affichage 0 1 C Pr cision 1 C Capteur NTC avec 2m de c ble Contr le du chauffage charge r sistive par ex r chauffeur max 1600W Contr...

Page 15: ...p rieure celle du r gulateur sinon il ne fonctionnera pas correctement La prise de refroidissement marqu e d un II et du symbole du flocon de neige peut faire fonctionner un ventilateur pour le refroi...

Page 16: ...inon il ne fonctionnera pas lorsque la prise sera allum e Si vous souhaitez utiliser un l ment de refroidissement branchez le dans la prise marqu e du symbole II et flocon de neige Si le dispositif es...

Page 17: ...Une fois cette op ration termin e confirmez en appuyant sur le bouton SET 2 R glage du diff rentiel de refroidissement Le symbole du flocon de neige doit clignoter en haut gauche de l cran pour indiq...

Page 18: ...e la temp rature du capteur soit entre 24 3 et 25 7 C ETALONNAGE Le r gulateur double fonction chauffage et refroidissement est talonn en usine et ne devrait pas n cessiter d autres r glages Il est to...

Page 19: ...ra ne des lectures erron es Modifiez l alarme afin que les r glages ne tombent pas dans les param tres de chauffage et de refroidissement d finis V rifiez que la sonde est correctement positionn e sel...

Page 20: ...TheAquariumSoln fb com theaquariumsolution FOLLOW US FOR INSPIRATION www theaquariumsolution com...

Reviews: