background image

INSTALLATION

Unpacking

Carefully open the shipping carton box and check for any 
noticeable damage. Every amplifier has been QC tested 
and inspected before leaving the factory. If any damage 
may  had  happened  during  transportation  notify  the 
incidence  to  the  shipping  company  immediately.  Keep 
the carton box in case you need to ship the amplifier to an 
authorized service center.

Rack Mounting

Free airflow, front to rear, of the amplifier unit must be 
allowed.  Therefore,  no  doors  or  rack  lids  should  be 
mounted in front of or behind the amplifiers in order to 
not block the airflow necessary to cool the units.

Amplifiers may be installed stacked directly one on top of 
each other, but the ideal configuration would be spacing 
them vertically 1 rack unit.

It is recommended to assembly the rear brackets 
provided 

 

with the units when fixing them to a rack:

Cooling

The amplifier uses a forced air cooling system with front to 
rear  airflow  in  order  to  maintain  a  controlled  operation 
temperature. 

The cooling fans suck cool air in through the front and 
blow  hot  air  out  at  the  rear  of  the  unit  through  the 
ventilating grills. The front and rear of the amplifier should 
have free exposure to the air (i.e. in a rack leave the front & 
rear doors off), with 2cm air gap at the sides.

It  is  also  very  important  to  keep    clean  the  dust  filters 
located  behind  the  detachable  front  panel  in  order  to 
ensure always maximum air flow.

The filter behind the air intake apertures on the front of 
your amplifier should be cleaned or replaced periodically, 
e.g.  12-24  months.  (Filters  in  amplifiers  located  in  more 
'dirty'  atmospheres  may  require  more  f requent 
maintenance).

The filter should be 'dry' cleaned, using a vacuum cleaner 
preferably.  Running  the  unit  without  a  filter  is  not 

Operating Voltage

The  label  placed  close  to  the  mains  cable  at  the  rear 
amplifier panel indicates the nominal operating voltage 
of the unit.  Be sure of the nominal voltage required by the 
amplifier before connecting it to the mains.

In case the power connector supplied with the power cord 
is  not  valid  for  you  area  /  region  it  would  need  to  be 
removed  and  replaced  by  a  convenient  one  wired  as 
follows:

Rear mounting brackets and hardware provided

Insert the Screw + Washer and fix the bracket to the rear 
panel for permanent installation

Use the Spacer for non permanent installation

6

EP

 series / 

User’s Manual

BLACK or BROWN
WHITE or BLUE
GREEN or GREEN/YELLOW

LIVE
NEUTRAL
EARTH (GROUND)

Once a suitable AC supply is connected to the unit, the 
amplifier can be turned on using the front panel power 
switch.  The  amplifier  will  start  a  short  auto-check 
sequence:
- Power led will lit in green.
- The fans will blow at the highest speed before dropping 
to idle state. 
-  Mute  leds  will  indicate  that  all  output  channels  are 
muted during the test. After 3 seconds channels will be 
unmuted.

 The inrush current is controlled during the auto-check 
sequence enabling multiple amplifiers to be turned on at 
the same time.

2x

Power cables

115V areas

Use standard 15A Edison plug for models EP-2K4 and 
EP-6K4. One 20A circuit per amplifier.

Use Nema L5-30 Twist lock plug for models EP-10K4 and 
EP-22K4. One 30A circuit per amplifier.

230V areas

Use in all cases standard 16A Schuko plug.

Summary of Contents for EP Series

Page 1: ...User s Manual Before operating the device please read the Safety precautions section of this manual Retain this manual for future reference EP 450 EP 2K4 EP 6K4 EP 10K4 EP 22K4 EP SERIES...

Page 2: ...ION INTRODUCTION 6 7 FRONT PANEL 7 8 8 9 10 REAR PANEL 3 SAFETY PRECAUTIONS 4 WARRANTY 5 DECLARATION OF CONFORMITY 12 SPECIFICATIONS 12 LINE DRAWINGS 14 ANNEX Line connections unbalanced and balanced...

Page 3: ...when unused for long periods of time Do not install near any heat sources such as radiators stoves or other apparatus that produce heat Do not block any ventilation openings install in accordance wit...

Page 4: ...ct use of the product All warranty repairs must be exclusively undertaken by the factory or any of its authorised service centers To claim a warranty repair do not open or intend to repair the product...

Page 5: ...on requirements EN 55103 2 2009 Electromagnetic compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus for professional use Part 2 Immunity EN...

Page 6: ...periodically e g 12 24 months Filters in ampli ers located in more dirty atmospheres may require more f requent maintenance The lter should be dry cleaned using a vacuum cleaner preferably Running th...

Page 7: ...amplifier is turned on mute leds will appear active red while the amplifier is doing an auto test After three seconds the MUTE leds will be deactivated E Bride Mode When active rear panel dips the led...

Page 8: ...connecting pins 1 NL4 connectors for outputs A and C include 4 active connecting pins 1 and 2 By doing this the user may have all the four output channels connected to 2 cables When using channels in...

Page 9: ...hannel A will manage both channels Opera on of Channels C and Channel D will be the same STEREO PARALLEL BRIDGE STEREO PARALLEL BRIDGE STEREO PARALLEL BRIDGE FRONT PANEL A Level control Four level pot...

Page 10: ...ability Hard or Soft limiting mode When hard mode is enabled the attack time of the limiter is shorter and allows less peaks to be driven to the load Gain Globally affects all channels From 23 dB to 4...

Page 11: ...ot Pin 3 Cold Unbalanced Input Connections These type of connection is not recommended for professional audio applications as it may cause noise in the installation Cables and Output Connectors Use on...

Page 12: ...rcuitry Frequency Response Voltage Gain Controls Cooling Amplifier Protections LED Indicators Audio Signal Input Connectors Speaker Output Connectors AC Power Requirements 115A 4 Switched Amplificatio...

Page 13: ...output channles 3 Turnup the level from the source 4 Change the amplifier s mode from Stereo to Bridge 100 70V 1 Read the appendix of this manual to make a correct unbalanced to balanced cable 2 Conn...

Page 14: ...ut the two signals get summed with opposite sign so that noise is cancelled out while the programme signal doubles in level Most professional audio devices use balanced inputs and outputs Connectors t...

Page 15: ...NC 6900 NW 52th Street Miami FL 33166 U S A TOLL FREE 1 888 DAS 4 USA DAS Audio Asia PTE LTD 3 Temasek Avenue Centennial Tower 34 36 Singapore 039190 Tel 65 6549 7760 DAS do Brasil LTDA Rua Dos Andrad...

Reviews: