AMPLIFIER
Description
1) INPUT :
XLR-type input signal connector. This is a balanced
connector just like the LOOP THRU connector with the
following pin assignments:
1 =GND (ground).
2 =(+) Non inverted input.
3 =(-) Inverted input.
2) LOOP THRU :
XLR-type output signal connector for connecting
several units together and sending them all the same
signal.
3) IN :
RJ45 connector for
4) OUT :
,
5) ON :
Green LED indicates that the unit is ON.
6) IDENTIFY/COMMS :
The Orange LED is flashing when IDENTIFY is pressed
(to identify the unit) or when
7) SIGNAL/LIMIT :
Bi-color LED indicates signal presence, when LED is
green, and that the limiter of amplifier is acting, when LED
is red.
8) AMP. PROTECT :
Red LED indicates that the protection of one or more
RJ45 connector for
several units together and sending them all the same
signal.
use.
9) DISPLAY :
The 2x16 display shows messages or data
10) KEYBOARD :
keyboard with 5 buttons for setting or selecting amplifier mode.
11) MODEL :
Label for
convert 1560A
or
model.
12) QR :
QR symbol to access the manuals via Internet connection.
13) ID DASNET :
Identification number label of the unit for to use with
(more information in section: CHANGE OF
CONFIGURATION). This information also appears when you turn ON the unit.
14) AC INPUT :
PowerCon TRUE1 type Neutrik connector for mains. Only use this equipment with an appropriate
mains cord.
15) AC OUTPUT :
16) HEATSINK :
Be careful when in contact with radiator because it can be hot, although it never will reach a dangerous
temperature.
convert 1590A
PowerCon TRUE1 type Neutrik connector for mains output. Only use this equipment with an
appropriate mains cord.
11
Manual del Usuario
/ convert
15A
series /
User’s Manual
convert 15A series
Amplifier
02394
7
13
14
15
12
16
1
2
3
4
9
6
8
5
10
11
NOTE: When you turn ON the unit, the display shows the messages:
And, depending on the model, one of these two messages.
Finally, after a few seconds the screen turns off.
convert 1590A
convert 1560A