3  SAFETY AND INSTALLATION PRECAUTIONS 

 

WARNINGS AND SYMBOLS

 

Safety instructions and warnings are marked in this manual by the following pictograms:  

CAUTION  

Special data, restrictions and rules with regard to preventing damage.  
 

WARNING  

A WARNING refers to possible injury to the user or significant material damage to the Signal Interface 
if the user does not (carefully) follow the procedures. 

 

A procedure, circumstance, etc, which deserves extra attention. 

 

    USE FOR INTENDED PURPOSE  

1.  The Signal Interface is constructed as per the applicable safety-technical guidelines. 

 

2.  Use the Signal Interface only: 

 

  In technically correct conditions  

  In a closed space, protected against rain, moisture, dust and condensation  

  Observing the instructions in the installation manual 

WARNING 

Never use the Signal Interface in locations where there is danger of gas or dust explosion 

or potentially flammable products!  
 

3.  Use of the Signal Interface other than mentioned in point 2 is not considered to be consistent with the 

intended purpose. BEP Marine is not liable for any damage resulting from the above.  

  ORGANIZATIONAL MEASURES 

The user must always: 

 

  Have access to the user's manual and be familiar with the contents of this manual 

 

  MAINTENANCE AND REPAIR 

  Switch off supply to the system

 

  Be sure that third parties cannot reverse the measures taken

 

  If maintenance and repairs are required, only use original spare parts 

 

  GENERAL SAFETY AND INSTALLATION PRECAUTIONS  

  Connection and protection must be done in accordance with local standards 

  Do not work on the Signal Interface or system if it is still connected to a power source. Only allow changes 

in your electrical system to

be carried out by qualified electricians 

 

  Check the wiring at least once a year. Defects such as loose connections, burned cables, etc. must be 

corrected immediately 

 

Summary of Contents for 80-911-0013-00

Page 1: ...Signal Interface SI User Installation Manual V2 0...

Page 2: ...rpose 4 Organizational Measures 4 Maintenance and Repair 4 General Safety and Installation Precautions 4 4 OVERVIEW 5 Description 5 Features 5 Component Overview 5 5 INSTALLATION 6 Guidelines 6 Connec...

Page 3: ...ines and measures Please keep this manual in a secure place GUARANTEE SPECIFICATIONS BEP Marine guarantees that this unit has been built according to the legally applicable standards and specification...

Page 4: ...Signal Interface in locations where there is danger of gas or dust explosion or potentially flammable products 3 Use of the Signal Interface other than mentioned in point 2 is not considered to be co...

Page 5: ...t switch Accepts inputs from industry standard tank senders 0 5V 10 180 Ohm 240 33 Ohm Accepts inputs from general voltaic or resistive signals can be used for controlling outputs or to display a phys...

Page 6: ...ut 8 used as reference to ground Connect each input to SI inputs 1 6 Input 7 is not connected Connect an NMEA2000 drop cable from the SI to the NMEA2000 backbone Ensure NMEA2000 network is properly te...

Page 7: ...00 Network LED lights up It may also be flashing if other devices are present and transmitting data 4 Check that the Power indicator LED is green 5 Check the circuit s status LEDs for each individual...

Page 8: ...d Flash Configuration Conflict 3x Red Flash Dip Switch Conflict 4x Red Flash Memory Comms Failure 5x Red Flash No Modules Detected 6x Red Flash Fault On Output 7x Red Flash Output Not Detected 8x Red...

Page 9: ...hese labels are to be fitted to the cover and to the module this prevents covers being swapped To record the module type and dipswitch settings use a permanent marker and strike through the applicable...

Page 10: ...ATTERY SEND NEG TANK SENDER 0 5 VOLT CIRCUIT BREAKER No connection DC Negative Signal input 1 Signal input 2 Signal input 3 Signal input 4 Signal input 5 Signal input 6 Signal inputs 10 180 Ohm Sender...

Page 11: ...11 EN CZone Signal Interface SI User Installation Manual 9 Dimensions Figure 9 Dimensions...

Page 12: ...CABLE GLAND for ZONE SI BK SILICON 80 911 0036 00 ERM BLOCK MI 8 WAY PLUG 5mm PITCH 80 911 0043 00 11 EMC ratings IEC EN 60945 IEC EN 61000 FCC Class B ISO 7637 1 12V Passenger cars and light commerci...

Page 13: ...13 EN CZone Signal Interface SI User Installation Manual 12 Declaration Of Conformity...

Reviews: