EN / CZone® Signal Interface (SI) User & Installation Manual

 

12

 

 

         

10  Ordering Information 

  MODULE 

Description  

Part number  

CZONE SIGNAL INTERFACE c/w SEALS & CONN 

80-911-0013-00 

CZONE SIGNAL INTERFACE NO SEALS & CONN 

80-911-0014-00 

 

  ACESSORIES AND SPARES 

Description  

Part number  

SEAL CABLE GLAND for ZONE SI BK SILICON 

80-911-0036-00 

ERM BLOCK MI 8 WAY PLUG 5mm PITCH 

80-911-0043-00 

 

11  EMC ratings 

  IEC EN 60945 

  IEC EN 61000 

  FCC Class B 

  ISO 7637 - 1 (12V  Passenger cars and light commercial vehicles with nominal 12 V supply voltage - 

Electrical transient conduction along supply lines only)  

  ISO 7637 - 2  (24V Commercial vehicles with nominal 24 V supply voltage - Electrical transient 

conduction along supply lines only) 

  IEC Standards for indirect lighting strikes  

 

 

Summary of Contents for 80-911-0013-00

Page 1: ...Signal Interface SI User Installation Manual V2 0...

Page 2: ...rpose 4 Organizational Measures 4 Maintenance and Repair 4 General Safety and Installation Precautions 4 4 OVERVIEW 5 Description 5 Features 5 Component Overview 5 5 INSTALLATION 6 Guidelines 6 Connec...

Page 3: ...ines and measures Please keep this manual in a secure place GUARANTEE SPECIFICATIONS BEP Marine guarantees that this unit has been built according to the legally applicable standards and specification...

Page 4: ...Signal Interface in locations where there is danger of gas or dust explosion or potentially flammable products 3 Use of the Signal Interface other than mentioned in point 2 is not considered to be co...

Page 5: ...t switch Accepts inputs from industry standard tank senders 0 5V 10 180 Ohm 240 33 Ohm Accepts inputs from general voltaic or resistive signals can be used for controlling outputs or to display a phys...

Page 6: ...ut 8 used as reference to ground Connect each input to SI inputs 1 6 Input 7 is not connected Connect an NMEA2000 drop cable from the SI to the NMEA2000 backbone Ensure NMEA2000 network is properly te...

Page 7: ...00 Network LED lights up It may also be flashing if other devices are present and transmitting data 4 Check that the Power indicator LED is green 5 Check the circuit s status LEDs for each individual...

Page 8: ...d Flash Configuration Conflict 3x Red Flash Dip Switch Conflict 4x Red Flash Memory Comms Failure 5x Red Flash No Modules Detected 6x Red Flash Fault On Output 7x Red Flash Output Not Detected 8x Red...

Page 9: ...hese labels are to be fitted to the cover and to the module this prevents covers being swapped To record the module type and dipswitch settings use a permanent marker and strike through the applicable...

Page 10: ...ATTERY SEND NEG TANK SENDER 0 5 VOLT CIRCUIT BREAKER No connection DC Negative Signal input 1 Signal input 2 Signal input 3 Signal input 4 Signal input 5 Signal input 6 Signal inputs 10 180 Ohm Sender...

Page 11: ...11 EN CZone Signal Interface SI User Installation Manual 9 Dimensions Figure 9 Dimensions...

Page 12: ...CABLE GLAND for ZONE SI BK SILICON 80 911 0036 00 ERM BLOCK MI 8 WAY PLUG 5mm PITCH 80 911 0043 00 11 EMC ratings IEC EN 60945 IEC EN 61000 FCC Class B ISO 7637 1 12V Passenger cars and light commerci...

Page 13: ...13 EN CZone Signal Interface SI User Installation Manual 12 Declaration Of Conformity...

Reviews: