13
EN / CZone® Output Interface (OI) User & Installation Manual
NETWORK CONFIGURATION
CZone modules communicate with each other over a NMEA2000 CAN BUS network. Each module needs a unique
address, this is achieved by carefully setting the dipswitch on each module with a small screwdriver. The dipswitch on
each module must match the setting in the CZone configuration. Refer to CZone Configuration Tool Manual on
instructions on creating and editing a CZone configuration.
•
To install the OI with other networked CZone modules, or to achieve advanced functionality such as
timers, load shedding or one touch Modes of operation, a custom configuration needs to be installed.
•
Set the dipswitch on the OI to match the configuration file.
•
All other CZone modules must have the dipswitch set to same as the configuration file.
The example below shows a dipswitch setting of 01101100 where 0 = OFF and 1 = ON
Setting Dipswitch
IMPORTANT -
Each CZone device must have a unique dipswitch number and the dipswitch of the device
must match the dipswitch set in the configuration file.
CIRCUIT IDENTIFICATION LABELS
Standard BEP circuit breaker panel labels are used to indicate the circuit name for each output
LAB
EL
LAB
EL
LAB
EL
LAB
EL
LAB
EL
LAB
EL
1
2
3
4
5
6
8
7
6
5
4
3
D
IP
2
1
DI
M
OI
SCI
MI
SI
OI
XX
OI Labels