![CZone 80-911-0009-00 User & Installation Manual Download Page 14](http://html1.mh-extra.com/html/czone/80-911-0009-00/80-911-0009-00_user-and-installation-manual_2707071014.webp)
EN / CZone® Output Interface (OI) User & Installation Manual
14
MODULE IDENTIFICATION LABEL
These labels allow easy identification of each module whilst recording the dipswitch setting. These labels are to be
fitted to the cover and to the module (this prevents covers being swapped). To record the module type and dipswitch
settings use a permanent marker and strike through the applicable boxes (a strike through on a dipswitch box indicates
that switch is on).
FIT THE COVER
1. Slide the cable gland up the output wires ensuring it is correctly seated.
2. Firmly push the top cover on to the OI until you hear it click into pace on each side.
3. Ensure the cable gland is still correctly in place.
4.
Install circuit labels if you have purchased a label sheet.
WARNING!
The OI is only ignition protected with the cover correctly installed.
INITIAL POWER UP
1. Power up the NMEA2000 Network, system will flash all outputs for a short time while booting.
2. Check that the Network Status LED lights up. It may also be flashing if other devices are on the network and
transmitting data.
3. Turn the switch/circuit breaker on supplying power to the input stud (if fitted).
4. Check the software version on the OI with the CZone Configuration Tool and update if necessary.
5. Write the configuration file to the network (Refer to the CZone Configuration Tool Instructions for details on how
to write a CZone configuration file).
6. Test all outputs for correctly configured functionality.
7. Check the circuit status LED’s for each individual circuit. Refer to LED codes to diagnose any faults which need
to be rectified.
XX
OI
SI
MI
SCI
MOI
DI
1 2
DIP
3 4 5 6 7 8
Fit The Cover