SPX-7400  Setup - Using Expansion Modules 

Before using EXP-2000 Expansion modules with the SPX-7400 system, it will be necessary to perform a short 
configuration process.  This process determines if the 7400 will utilize expansion modules, and if so, how many will be 
used with the system.  Each SPX-7400 link can support up to 7 expansion modules.  

SPX-7400 units are shipped in the factory default condition.  Factory default units will be setup to function as 
SPX-7400 units without expansion modules.  Only communications between the 2 gateway units will be active.  

Setup Process

:

1. With power off, set the DIP switch on the Central unit according to the table below.

2. Apply power.
    The Diagnostic LED should display a steady Green indication.

3. Remove power
    Set DIP switch #1 OFF.  Any other DIP switches can now be set  as required (Reader family/ Pullup resistors).
    The Central unit is now configured.  No expansion module configuration is required for the Remote unit.

4. The expansion modules will need to be setup and correctly addressed. See EXP-2000 manual for details of     
    Expansion module setup and configuration.  The Expansion units are addressed, and added to the system as pairs.

5.  Connect the Expansion modules into the system as indicated in this wiring diagram.

Operation with Expansion Modules:

The SPX-7400 system Remote and Central gateway units will operate as a standard pair Suprex® units,  all of the I/O 
and data terminals are available for use with readers and access control systems.  There are some minor differences 
in operation when using the expansion modules.  Each pair of 

1. The Diagnostic LED on the Gateway units will indicate the status of the main (gateway) communication link only.

2. The Alarm relay on the Central Gateway unit will deactivate (indicate alarm condition) when the communication fails 
between the Gateway units or ANY of the the Remote or Central Expansion units.

3.  Paired Expansion units will be functionally similar to the standard SPX-1300 Wiegand Suprex® system.

Central Unit Configuration Mode Settings

"

"

"

         Switch

"

"

"

1  2  3  4  5  6  7  8

Gateway only - No EXP

"

1  0  0  1  0  0  0  0

1 EXP Pair used 

""

1  0  0  1  0  0  0  1

2 EXP Pair used

" "

1  0  0  1  0  0  1  0

3 EXP Pair used

" "

1  0  0  1  0  0  1  1

4 EXP Pair used

" "

1  0  0  1  0  1  0  0

5 EXP Pair used

" "

1  0  0  1  0  1  0  1

6 EXP Pair used

" "

1  0  0  1  0  1  1  0

7 EXP Pair used

" "

1  0  0  1  0  1  1  1

1 2 3 4 5 6 7 8

1 = ON

0 = OFF

See  EXP-2000 Manual for further setup instructions

Summary of Contents for Suprex SPX-7400 Series

Page 1: ...SPX 7400_MAN_082112 SPX 7400 Series Suprex Reader Extender Fiber Optic Interface Operations Manual SPX 7400 shown with EXP 2000 ...

Page 2: ...ifications Module connections utilize standard ST style connections NOTE Single Mode or Multi Mode must be Specified at time of order SPX 7400 Multimode Loss Budget 13 dB 850 nm 62 5 125 Fiber Loss Budget 9 dB 850 nm 50 0 125 Fiber SPX 7410 Single mode Loss Budget 20 dB 1300 nm 9 125 Fiber Physical SPX 7400 Aluminum Enclosure 4 45 x 3 08 x 2 0 Each Unit SPX 7400 Aluminum Enclosure 4 45 x 3 08 x 2 ...

Page 3: ...0 644 Strobed Rising Mag Tek Strobed Falling Edge Reserved F2F x ON 1 2 3 4 5 6 7 8 Dip switch 4 is ON Enable Pullup resistors Dip switch 4 is OFF Disable Pullup resistors DIP Switch 1 OFF See appendix for Expansion module Setup Remote Unit Settings 1 8 to 16 VDC In 2 Ground Status LED 1 exp 2 exp 3 5 VDC out 4 Prog Res 4 5 Prog Res 3 6 LED In 7 D1 Data out 8 D0 Clk out 1 Relay 2 N O 2 Relay 2 Com...

Page 4: ...Access Control Panel 8 to 16 VDC Ground Diagnostic LED R1 Input Controls Strike on Remote R1 IN LED In D1 Data Out D0 Clock Out Card Reader DC Power Supply R1 N O R1 Com R1 N C Door Strike Output 8 to 16 VDC Ground Diagnostic LED LED Out D1 Data In D0 Clock In See page 10 for other strike control options ...

Page 5: ...Fiber Optic Connections Fiber Optic Interface SPX 7400 Central Fiber Optic Interface SPX 7400 Remote TX RX TX RX ...

Page 6: ...ting curve The Suprex units should be operated with a filtered 12 Volt nominal DC supply Any voltage between 8 and 16 volts can be utilized by following the temperature voltage derating curve Voltage should not exceed 16 VDC under normal operating conditions Temperature Rating vs Voltage Derating Curve ...

Page 7: ...Cypress Suprex SPX 7400 Enclosure Dimensions 1 70 2 00 3 08 0 80 0 80 3 15 4 45 ø0 20 X 4 ...

Page 8: ...ch a jumper wire from the Ground connection the the Relay 1 input on the Central unit Relay 1 on the Remote unit should activate with an audible click A VOM or continuity tester should show the Relay 1 normally open contacts on the Remote unit closing when the Relay 1 input is activated connected to ground on the Central unit 6 Units are shipped from the factory set for the Wiegand data format If ...

Page 9: ...uminated on the unit s then the unit is not getting power or there is an electrical problem The Diagnostic LED s will be illuminated Red Green or flashing whenever power is applied CENTRAL UNIT FLASHING BETWEEN RED GREEN With power applied and no communication path between the Remote and Central the Central unit will flash the diagnostic indicator alternately between Red and Green REMOTE UNIT ILLU...

Page 10: ...e two relays available for accessory outputs at the Remote end Either relay can be used to provide the Door Strike or Gate activation function This example uses Relay 1 Wiring Example Door Strike Follows LED Access Control Panel LED In R1 IN R1 Input Controls Strike on Remote Suprex Central Ground LED Signal Ground Only Relay and LED Connections are shown for clarity refer to previous diagrams for...

Page 11: ...hing connected the associated output will be set to a high level When the input is set to 0Volts Ground the input will activate its associated output All Accessory outputs are Open Collector type and will switch to Ground when activated Each input will have an associated output See the following pages for a diagram of each I O pair Inputs can be tested by making a jumper connection to ground and m...

Page 12: ...row denotes direction of command signal Relay 1 IN Input Signal Relay 1 N O Relay 1 Com Relay 1 N C Contact Outputs Suprex Central Suprex Remote Relay 2 N O Relay 2 Com Relay 2 N C Contact Outputs Relay 2 IN Input Signal Suprex Central Suprex Remote ...

Page 13: ... units Relay 3 is activated when power is applied and the communication link between the Central and Remote is functioning Relay 3 will become deactivated Alarm condition when either the Relay 3 input on the remote is active OR the Remote unit is unable to communicate with the Central unit See APP NOTE FOR DETAILS Relay 4 N O Relay 4 Com Relay 4 N C Suprex Remote Contact Outputs Relay 4 IN Input S...

Page 14: ...hese resistance values locally at the panel so that the correct supervised status is maintained At the same time the Remote unit must maintain supervision of the wires connected to the relays and switches that are connected to the remote access point The contact supervision is provided by the Remote unit The Suprex system does this by comparing the value of programming resistor at the Central unit...

Page 15: ...ration The Expansion units are addressed and added to the system as pairs 5 Connect the Expansion modules into the system as indicated in this wiring diagram Operation with Expansion Modules The SPX 7400 system Remote and Central gateway units will operate as a standard pair Suprex units all of the I O and data terminals are available for use with readers and access control systems There are some ...

Page 16: ...Link Multi drop Card Reader EXP 2000R 2 Door Parking Gate Cypress Suprex LYNK Fiber Optic Solution EXP 2000R 3 SPX 74X0C 1 EXP 2000C 3 ACS Fiberoptic Link EXP 2000R 4 EXP 2000R 8 SPX 74X0R 1 EXP 2000C 8 EXP 2000C 2 EXP 2000C 4 ...

Page 17: ...m RLY3 N C RS232 Out RS232 In Ground Aux Out Relay2 Input Relay1 Input Access Control Panel R1 Input Controls Strike on Remote DC Power Supply Additional EXP Modules 8 to 16 VDC Ground EXP EXP LED In D1 Data Out D0 Clock Out R1 IN SPX XXXX Central See EXP 2000 Manual for further setup instructions Cypress Suprex Series Wiegand Expansion Module Panel Central interface ...

Page 18: ... RLY2 N C RLY1 N O RLY1 Com RLY1 N C RS232 Out RS232 In Ground Aux In N C N C 485 485 5 VDC Out RLY4 Input 5V RLY3 Input 5V LED Output D1 Data F2F Input D0 CLK Input DC Power Supply Card Reader EXP EXP LED Out D1 Data In D0 Clock In 8 to 16 VDC In Ground SPX XXXX Remote R1 N O R1 Com R1 N C Door Strike Output See EXP 2000 Manual for further setup instructions ...

Reviews: