Setup and Verification
S6SAL211A31SA2001, S6SAL211A31SA3001 4ch 72W LED Driver and Communication Board Operation Guide, Document Number: 002-08632 Rev. *B 13
*1: Connect LED to all CH from CN_101 to CN_401. Refer to Figure 4-3.
*2: S6SATU03 can provide power to DALI communication lines from CN_DALI. This current limit is 50 mA (Supply voltage
= 12V-20V).We must consider this current when determining the number of connected DALI Slave. We have to select
the cable in consideration of the rated current and then rated voltage
*3: Beforehand, make a setup of PC and install software.
*4: A board of S6SAL211A31-DALI-SA2 is possible to buy as single item. (Part Number: S6SAL211A31SA2001)
Figure 4-3 Connection of 6SAL211A31-DALI-SA2 and LED
*1: Connect LED to all CH from CN_101 to CN_401. LED module(I
F
≥
1A, V
F
≈
3.2V, 5- series ) Be careful about polarity.
*2: Thermistor (THp,THm) is an option. Even if that isn't connected, a board operates.
4.2.3 GUI Control Function When Using S6SATU03
4.2.3.1 Preparing the Control GUI
Run DALI communication software (S6AL211_DALI_GUI.exe) after connecting the USB cable.
Show the message box below if the connecting GUI and DALI controller is success.
Otherwise, check USB cable connection or installation of the device driver.