CYBLE-022001-00
Document Number: 001-95662 Rev. *J
Page 17 of 40
XRES
Temperature Sensor
SAR ADC
Table 15. XRES DC Specifications
Parameter
Description
Min
Typ
Max
Units
Details/Conditions
V
IH
Input voltage HIGH threshold
0.7 × V
DDD
–
–
V
CMOS input
V
IL
Input voltage LOW threshold
–
–
0.3 × V
DDD
V
CMOS input
R
PULLUP
Pull-up resistor
3.5
5.6
8.5
k
–
C
IN
Input capacitance
–
3
–
pF
–
V
HYSXRES
Input voltage hysteresis
–
100
–
mV
–
I
DIODE
Current through protection diode to
V
DD
/V
SS
–
–
100
µA
–
Table 16. XRES AC Specifications
Parameter
Description
Min
Typ
Max
Units
Details/Conditions
T
RESETWIDTH
Reset pulse width
1
–
–
µs
–
Table 17. Temperature Sensor Specifications
Parameter
Description
Min
Typ
Max
Units
Details/Conditions
T
SENSACC
Temperature-sensor accuracy
–5
±1
5
°C
–40 to +85 °C
Table 18. SAR ADC DC Specifications
Parameter
Description
Min
Typ
Max
Units
Details/Conditions
A_RES
Resolution
–
–
12
bits
A_CHNIS_S
Number of channels - single-ended
–
–
6
6 full-speed
A-CHNKS_D
Number of channels - differential
–
–
3
Diff inputs use neighboring I/O
A-MONO
Monotonicity
–
–
–
Yes
A_GAINERR
Gain error
–
–
±0.1
%
With external reference
A_OFFSET
Input offset voltage
–
–
2
mV
Measured with 1-V V
REF
A_ISAR
Current consumption
–
–
1
mA
A_VINS
Input voltage range - single-ended
V
SS
–
V
DDA
V
A_VIND
Input voltage range - differential
V
SS
– V
DDA
V
A_INRES
Input resistance
–
–
2.2
k
A_INCAP
Input capacitance
–
–
10
pF
VREFSAR
Trimmed internal reference to SAR
–1
–
1
%
Percentage of Vbg (1.024 V)
Note
9. A maximum of six single-ended ADC Channels can be accomplished only if the AMUX Buses are not being used for other funcitonality (e.g. CapSense). If the
AMUX Buses are being used for other functionality, then the maximum number of single-ended ADC channels is four. Similarly, if the AMUX Buses are being
used for other functionality, then the maximum number of differential ADC channels is two.