4-4.
Tool Usage Procedures
The following are the test procedures of Windows Production Test tool.
4-4-1.
Windows Production Server Program Setting
The Windows Production Test Server program is an echo server program. It will reply all
packets it received. The sent packet payload is the same as received packet payload. The
following is user interface of Windows Production Test Server program.
Figure 18.
Windows Production Test Server Setting
The Windows Production Test Server setup procedures:
1.
Configure a proper IP address (e.g. 192.168.0.1) for Server PC’s NIC card.
2.
Set a correct IP address (e.g. 192.168.0.1) of Server PC in the “Host Address” field.
3.
Select TCP or UDP packet type in the “Setting” field and set a correct port number of
TCP or UDP packets.
4.
Press “Start” button to start Windows Production Test Server.
Note:
The Server IP address, the TCP/UDP packet type and port number settings of
Windows Production Test Server should be the same as that in Windows Production Test
program.