CY7C1324H
Document #: 001-00208 Rev. *B
Page 13 of 15
ZZ Mode Timing
[19, 20]
Notes:
19. Device must be deselected when entering ZZ mode. See Cycle Descriptions table for all possible signal conditions to deselect the device.
20. DQs are in High-Z when exiting ZZ sleep mode.
Timing Diagrams
(continued)
t
ZZ
I
SUPPLY
CLK
ZZ
t
ZZREC
ALL INPUTS
(except ZZ)
DON’T CARE
I
DDZZ
t
ZZI
t
RZZI
Outputs (Q)
High-Z
DESELECT or READ Only
[+] Feedback