40
(1) Power
Press this switch to toggle the unit’s power between ON and OFF (standby
mode).
!
Note: While in standby mode the unit’s WebGUI, Telnet and RS-232
controls are still active.
(2) Lock
Press this switch to enable or disable the front panel button lock function.
When enabled, pressing the physical buttons on the front of the unit will
have no effect.
(3) Network
IP mode may be switched between Static IP or DHCP. In Static IP mode the
IP, netmask and gateway addresses may be manually set. When in DHCP
mode, the unit will attempt to connect to a local DHCP server and obtain
IP, netmask and gateway addresses automatically. Please press “Save” after
making any changes to the IP configuration or mode.
!
Note: The unit’s default IP address is 192.168.1.50. If the IP address is
changed then the IP address required for WebGUI/Telnet access will also
change accordingly.
(4) Download Current Configuration
The current system configuration, including routing and presets, may
be saved as an JSON file to a PC. Click the “Download” button to save the
current system configuration to your local PC.
(5) Restore Configuration
Previously saved system configurations may be restored from a saved
JSON file. Click the “Choose File” button to locate the saved JSON file, then
click the “Restore” button.
(6) Reset to Default
Press the “ALL Reset” button to reset the unit to its factory default state.
After the reset is complete, the unit will reboot automatically.
(7) Firmware Upgrade
To update the unit's firmware, click the “Choose File” button to open the
file selection window and then select the firmware update file (*.bin
format) located on your local PC. After selecting the file, click the “Upgrade”
button to begin the firmware update process.