![CYP CH-2540RX Operation Manual Download Page 27](http://html.mh-extra.com/html/cyp/ch-2540rx/ch-2540rx_operation-manual_2705434027.webp)
22
■
IR Command:
Shows the IR command (in ASCII hex pairs)
that will be sent when the specified Automation Event is
activated. Click the “Edit” icon ( ) to learn the command from an IR
remote. Click the “Test” button to send the command immediately.
3) CEC:
Enable or disable sending a CEC command when the currently
selected Automation Event is activated.
Note: CEC support must also be enabled on the connected HDMI display
device.
■
Delay:
Set the length of time, in seconds, that the specified
Automation Event must continue to be true before sending the
defined CEC command.
■
Wait:
Set the length of time, in seconds, to wait after this IR
Automation Event has been activated before ANY other Automation
Event can be detected.
■ CEC Command:
Set the CEC command to send when the specified
Automation Event is activated. Click the “Test” button to send the
command immediately. Available CEC commands are:
– Power Off:
Turn off the connected HDMI display device.
– Power On:
Turn on the connected HDMI display device.
– Active Source:
Force the connected HDMI display device to
switch to the HDMI input that this unit is connected to.
Note: Not all HDMI devices support all CEC commands.
4) RS232:
Enable or disable sending an RS-232 command when the
currently selected Automation Event is activated. Click the Edit icon ( )
to configure the RS-232 port.