background image

19

COMMAND

Description and Parameters

SET ALL IN EDID N1

Set the EDID to use when set to “All mode”.
Available values for 

N1

  [8-bit/1080p/2CH 

LPCM] 

  [8-bit/1080p/MCH] 

  [12-bit/4K@30/2CH 

LPCM] 

  [12-bit/4K@30/MCH] 

  [12-bit/4K@60/2CH 

LPCM] 

  [12-bit/4K@60/MCH] 

  [User 

1] 

  [User 

2] 

  [User 

3] 

10 

  [Sink 

A]

GET ALL IN EDID

Show the current “All mode” EDID.

SET IN N1 EDID N2

Assign the specified EDID to the specified input in “Appoint mode”.

N1

 = 1~3 

 

[Input number]

Available values for 

N1

  [8-bit/1080p/2CH 

LPCM] 

  [8-bit/1080p/MCH] 

  [12-bit/4K@30/2CH 

LPCM] 

  [12-bit/4K@30/MCH] 

  [12-bit/4K@60/2CH 

LPCM] 

  [12-bit/4K@60/MCH] 

  [User 

1] 

  [User 

2] 

  [User 

3] 

10 

  [Sink 

A]

GET IN N1 EDID

Show the EDID currently assigned to input N1.

N1

 = 1~3 

 

[Input number]

Summary of Contents for CH-2537TXM-TB

Page 1: ...CH 2537TXM TB UHD 3 1 HDMI VGA over HDBaseT Table Box with PoH PD Operation Manual Operation Manual ...

Page 2: ... registered trademarks of HDMI licensing Administrator Inc ...

Page 3: ...Technology reserves the right to make improvements to this document and or product at any time and without notice COPYRIGHT NOTICE No part of this document may be reproduced transmitted transcribed stored in a retrieval system or any of its part translated into any language or computer file in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without expr...

Page 4: ...d into this product through any openings or empty slots in the unit as you may damage parts inside the unit Do not attach the power supply cabling to building surfaces Use only the supplied power supply unit PSU Do not use the PSU if it is damaged Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk on it To protect the unit from overheatin...

Page 5: ... 6 3 2 Automation Tab 9 6 3 3 EDID Settings Tab 11 6 3 4 System Settings Tab 13 6 4 Serial Control Via Receiver 14 6 5 Telnet Control 14 6 6 Serial and Telnet Commands 15 7 Connection Diagram 28 8 Specifications 29 8 1 Technical Specifications 29 8 2 Video Specifications 30 8 3 Audio Specifications 31 8 3 1 Digital Audio 31 8 3 2 Analog Input 32 8 4 Cable Specifications 32 8 5 HDBaseT Features 33 ...

Page 6: ...atures such as automatic switching based on input signal and hot plug detection enable convenient hands free operation A multi function button on the face of the unit provides access to an information OSD as well as allowing manual input selection Additional functionality such as EDID management HDCP management and basic signal event automation which can send customized RS 232 or CEC commands to e...

Page 7: ...omatic color space conversion of 4K 50 60Hz 4 4 4 8 bit or 4K any 10 12 bit sources Supports CEC bypass HDBaseT feature support HD Video and Audio 100BaseT Ethernet and PoH PD HDBaseT output transmits video audio and data over a single Cat 5e 6 7 cable and can reach distances up to 100m 328ft at 4K when using Cat 6A 7 Supports pass through of many audio formats including 8 channel LPCM Bitstream a...

Page 8: ...t input Green indicates Follow Display mode orange indicates Follow Source mode off indicates HDCP support is disabled 4 VGA IN LED This LED will illuminate when the VGA input is selected 5 INPUT SELECT Button A short press of this button will switch between the available inputs Pressing and holding this button for 2 seconds will activate the information OSD 6 HDMI IN 2 3 Ports and LEDs Connect to...

Page 9: ...end the network to both ends of the HDBaseT connection and to control the unit 6 2 Rear Panel CAT5e 6 7 OUT 1 1 CAT5e 6 7 OUT Port Connect to a compatible HDBaseT receiver with a single Cat 5e 6 7 cable for transmission of all data signals Power is also supplied via PoH by the connected PSE receiver Note The PoH function is designed to receive power from compatible receiver units only Other brands...

Page 10: ...address is 192 168 1 50 By clicking on one of the listed devices you will be presented with the network details of that particular device 1 IP Mode If you choose you can alter the static IP network settings for the device or switch the unit into DHCP mode to automatically obtain proper network settings from a local DHCP server To switch to DHCP mode please select DHCP from the IP mode drop down th...

Page 11: ...te The default user name and password is admin On the left side of the browser you will see the following menu tabs where all primary functions of the unit are controllable via the built in WebGUI The individual functions will be introduced in the following sections Clicking the red Logout tab will automatically log the currently connected user out of the WebGUI and return to login page ...

Page 12: ... the routing information displayed on the buttons will change accordingly 1 Output Click on the output button to begin routing selection followed by the selection of the preferred input Click on the Camera icon to mute or unmute the output Click the Edit icon to modify additional output settings 2 Edit Output This window provides options to rename the output enable auto switching set audio routing...

Page 13: ...display when freerun is active Available choices are Black Red Blue and Colorbars 3 Input Rename the inputs or modify the HDCP behavior HDMI inputs only by clicking on the Edit icon to open the editing window Click on Save to confirm and activate any changes made to a name Changes made to the HDCP behavior are applied immediately Apple Mode Completely disables HDCP support on the input Follow In H...

Page 14: ...wn to select the Automation Event to configure Available Automation Events are Power On This unit is powered on Out A Source Active The currently selected input changes from inactive to active Out A Source Lost The currently selected input changes from active to inactive CEC Enable or disable sending a CEC command when the currently selected Automation Event is activated Note CEC support must be e...

Page 15: ... devices Delay Set the length of time in seconds that the specified Automation Event must continue to be true before sending the defined RS 232 command Wait Set the length of time in seconds to wait after this RS 232 Automation Event has been activated before ANY other Automation Event can be detected RS 232 Command Click the Edit icon to define the RS 232 command to send when the specified Automa...

Page 16: ...rovided then click Save Name to confirm the change Download Click to download and save the current User EDID as a file bin on the connected PC Upload Click to upload a previously saved EDID file bin from the connected PC into the User EDID slot 2 Sink EDID Download Select and save the EDID from a connected display Drop down Menu Select the sink to read an EDID from for download Download Click to d...

Page 17: ...information This unit provides the following 6 default EDIDs Unit s Default EDIDs 8bit 2D PCM 1080p 2CH 1920 1080p 60Hz 4 95Gbps 8 bit color LPCM 2 0 8bit 2D PCM 1080p MCH 1920 1080p 60Hz 4 95Gbps 8 bit color LPCM 7 1 Bitstream 12bit 2D PCM 4K2K 30 2CH 3840 2160p 30Hz 10 2Gbps Deep Color 8 10 12 bit LPCM 2 0 12bit 2D PCM 4K2K 30 MCH 3840 2160p 30Hz 10 2Gbps Deep Color 8 10 12 bit LPCM 7 1 Bitstrea...

Page 18: ...fault password is admin 3 Network The IP Address Netmask and Gateway can be set manually or DHCP can be enabled for automatic IP configuration if your local network supports it Click on Save to confirm and activate any changes made to these settings 4 System Reboot Click this button to reboot the unit Factory Default Click this button to reset the unit to the factory default settings 5 Firmware Up...

Page 19: ...type cmd in the search field and press Enter Windows XP Click Start Run type cmd and press Enter Mac OS X Click Go Applications Utilities Terminal Once in the Command Line Interface CLI type telnet followed by the IP address of the unit and the port number if it is non standard and then hit Enter This will connect us to the unit we wish to control Microsoft Windows Version 6 1 7601 Copyright c 200...

Page 20: ...e GET MODEL TYPE Show the unit s product type SET FACTORY DEFAULT Reset the unit to its factory defaults SET FACTORY IPCONFIG DEFAULT Reset the unit s IP configuration to the factory defaults SET SYSTEM REBOOT Reboot the unit GET MAC 1 ADDR Show the unit s MAC address SET IP MODE N1 Set the IP address assignment mode Available values for N1 STATIC Static IP mode DHCP DHCP mode GET IP MODE Show the...

Page 21: ...T NETMASK N1 Set the netmask address N1 X X X X X 0 255 netmask GET NETMASK Show the current netmask SET GATEWAY N1 Set the gateway address N1 X X X X X 0 255 gateway address GET GATEWAY Show the current gateway address SET IN N1 NAME N2 Set the name of the specified input N1 1 3 Input number N2 Name 16 characters max GET IN N1 NAME Show the current name of the specified input N1 1 3 Input number ...

Page 22: ...t N1 1 3 Input number GET OUT A ROUTE Show the output s current routing source GET IN TYPE LIST Show each input s video type GET OUT TYPE LIST Show the video type of the output SET OUT A MASK N1 Enable or disable the output mask setting Available values for N1 OFF Mask disabled ON Mask enabled Note When an output is masked all video including the banner will be blanked out GET OUT A MASK Display t...

Page 23: ...UMBER Show the number of inputs on the unit GET OUT PORT NUMBER Show the number of outputs on the unit GET IN N1 SYNC STATUS Show the current sync status of the specified input N1 1 3 Input number Available Responses 0 No sync 1 Sync is active SET ALL IN EDID MODE N1 Enable or disable using the same EDID for all inputs Available values for N1 ON All mode OFF Appoint mode GET ALL IN EDID MODE Show ...

Page 24: ...User 1 8 User 2 9 User 3 10 Sink A GET ALL IN EDID Show the current All mode EDID SET IN N1 EDID N2 Assign the specified EDID to the specified input in Appoint mode N1 1 3 Input number Available values for N1 1 8 bit 1080p 2CH LPCM 2 8 bit 1080p MCH 3 12 bit 4K 30 2CH LPCM 4 12 bit 4K 30 MCH 5 12 bit 4K 60 2CH LPCM 6 12 bit 4K 60 MCH 7 User 1 8 User 2 9 User 3 10 Sink A GET IN N1 EDID Show the EDI...

Page 25: ...w the current name of user EDID N1 N1 7 9 EDID number SET IN N1 HDCP MODE N2 Set the HDCP mode to use with the specified HDMI input N1 2 3 HDMI input number Available values for N2 0 HDCP disabled 1 Follow source 2 Follow display GET IN N1 HDCP MODE Show the current HDCP mode of the specified input N1 2 3 HDMI input number SET AUDIO OUT A ROUTE N1 Set the audio source to use with the HDMI inputs A...

Page 26: ...A TYPE N1 Set the color to display when freerun is enabled and active Available values for N1 1 Black 3 Red 5 Blue 10 Color bar SET FREERUN A TYPE Show the current freerun display color GET FREERUN LIST List all available freerun colors GET AUTOMATION EVENT LIST List all Automation Event types SET AUTOMATION EVENT N1 UART N2 Enable or disable the specified Automation Event s RS 232 response Availa...

Page 27: ...Out A source lost N2 1 300 Delay in seconds GET AUTOMATION EVENT N1 UART DELAY Show the delay time for the specified Automation Event s RS 232 response Available values for N1 1 Power on 2 Out A source active 3 Out A source lost SET AUTOMATION EVENT N1 UART WAIT N2 SEC Set the length of time to wait after an Automation Event s RS 232 response has been activated before ANY other Automation Event ca...

Page 28: ...ted Available values for N1 1 Power on 2 Out A source active 3 Out A source lost N2 Command Max 32 characters GET AUTOMATION EVENT N1 UART COMMAND Show the RS 232 command string to be sent when the specified Auto mation Event is activated Available values for N1 1 Power on 2 Out A source active 3 Out A source lost SET AUTOMATION EVENT N1 CEC N2 Enable or disable the specified Automation Event s CE...

Page 29: ...ut A source lost N2 1 300 Delay in seconds GET AUTOMATION EVENT N1 CEC DELAY Show the delay time for the specified Automation Event s CEC re sponse Available values forr N1 1 Power on 2 Out A source active 3 Out A source lost SET AUTOMATION EVENT N1 CEC WAIT N2 SEC Set the length of time to wait after an Automation Event s CEC re sponse has been activated before ANY other Automation Event can be d...

Page 30: ...ecified Automation Event is activated Available values for N1 1 Power on 2 Out A source active 3 Out A source lost Available values for N2 1 CEC power off 2 CEC power on 3 CEC active source GET AUTOMATION EVENT N1 CEC COMMAND Show the CEC command to be sent when the specified Automation Event is activated Available values for N1 1 Power on 2 Out A source active 3 Out A source lost SET UART 1 MODE ...

Page 31: ...400 baud 19200 19200 baud 38400 38400 baud 57600 57600 baud 115200 115200 baud GET UART 1 BAUDRATE Show the current RS 232 baud rate SET UART 1 STOP BIT N1 Set the number of RS 232 stop bits to use N1 1 2 Stop bits GET UART 1 STOP BIT Show the current RS 232 stop bits setting SET UART 1 DATA BIT N1 Set the number of RS 232 data bits to use N1 5 8 Data bits GET UART 1 DATA BIT Show the current RS 2...

Page 32: ...1 PARITY N1 Set the parity value for RS 232 Available values for N1 0 None 1 Odd 2 Even GET UART 1 PARITY Show the current RS 232 parity setting Note Commands will not be executed unless followed by a carriage return Commands are not case sensitive ...

Page 33: ...WR LINK HDCP VGA IN LAN INPUT SELECT VGA IN 1 AUDIO IN HDMI IN 3 HDMI IN 2 Laptop or PC Laptop or PC Game Console HDMI Input HDMI Output LAN LAN HDMI Input VGA Input Stereo Input Cat 5e 6 7 Cable Network Switch Power Supply Smart TV ...

Page 34: ...J 45 Service Port Hidden 1 USB 2 0 Type A Baud Rate 19200 Power Supply PoH from Rx ESD Protection HBM 8kV Air Discharge 4kV Contact Discharge Dimensions W H D 201mm 82mm 60mm Case Only 201mm 82mm 65mm All Inclusive Weight 467g Chassis Material Metal Aluminum Plastic Chassis Color Black Silver Operating Temperature 0 C 40 C 32 F 104 F Storage Temperature 20 C 60 C 4 F 140 F Relative Humidity 20 90 ...

Page 35: ... 60 720 576i 50 720 576p 50 800 600p 56 60 72 75 85 848 480p 60 1024 768p 60 70 75 85 1152 864p 75 1280 720p 50 60 1280 768p 60 75 85 1280 800p 60 75 85 1280 960p 60 85 1280 1024p 60 75 85 1360 768p 60 1366 768p 60 1400 1050p 60 1440 900p 60 75 1600 900p 60RB 1600 1200p 60 1680 1050p 60 1920 1080i 50 60 1920 1080p 24 25 30 1920 1080p 50 60 ...

Page 36: ... 4 2 0 3840 2160p 24 HDR10 3840 2160p 50 60 4 2 0 HDR10 3840 2160p 50 60 4096 2160p 24 25 30 4096 2160p 50 60 4 2 0 4096 2160p 24 HDR10 4096 2160p 50 60 4 2 0 HDR10 4096 2160p 50 60 8 3 Audio Specifications 8 3 1 Digital Audio HDMI Input HDBaseT Output LPCM Max Channels 8 Channels Sampling Rate kHz 32 44 1 48 88 2 96 176 4 192 Bitstream Supported Formats Standard High Definition ...

Page 37: ...e VGA Input 2m Ethernet Cable Cat 5e 6 100m 70m Cat 6A 7 100m 100m Bandwidth Category Examples 1080p FHD Video Up to 1080p 60Hz 12 bit color Data rates lower than 5 3Gbps or below 225MHz TMDS clock 4K30 4K UHD Video 4K 24 25 30Hz 4K 50 60Hz 4 2 0 8 bit color Data rates higher than 5 3Gbps or above 225MHz TMDS clock but below 10 2Gbps 4K60 4K UHD Video 4K 50 60Hz 4 4 4 8 bit 4K 50 60Hz 4 2 0 10 bit...

Page 38: ...andard Code for Information Interchange Cat 5e Enhanced Category 5 cable Cat 6 Category 6 cable Cat 6A Augmented Category 6 cable Cat 7 Category 7 cable CEC Consumer Electronics Control CLI Command Line Interface DHCP Dynamic Host Configuration Protocol DVI Digital Visual Interface EDID Extended Display Identification Data GbE Gigabit Ethernet Gbps Gigabits per second GUI Graphical User Interface ...

Page 39: ...hertz OSD On Screen Display PD Powered Device PoH Power over HDBaseT PSE Power Sourcing Equipment TCP Transmission Control Protocol 4K UHD 4K Ultra High Definition 10 2Gbps max 4K UHD 4K Ultra High Definition 18Gbps max UHDTV Ultra High Definition Television USB Universal Serial Bus VGA Video Graphics Array WUXGA RB Widescreen Ultra Extended Graphics Array Reduced Blanking XGA Extended Graphics Ar...

Page 40: ...CYPRESS TECHNOLOGY CO LTD www cypress com tw ...