background image

3

6.2 Rear Panel

DC 5V

+

Control

-

Relay

Out

1

3

2

1

 RELAY OUT: 

Connect with device that supports DC 0~24V/5A 

power or signal that supports relay function.

2

 Control: 

Connect from PC/Laptop with active internet service or 

Telnet or WebGUI control with RJ-45 terminated cable. This slot 

supports PoE PD 48V function which means when the connected 

server/Hub support PSE 48v it can be powered without DC supply 

connection.

3

 DC 5V: 

Plug the 5V DC power adaptor included in the package 

and connect to AC wall outlet for power supply.

6.3 Telnet Commands

COMMAND

DESCRIPTION

PARAMETER

IPCONFIG

Display the current IP 

configure

NONE

SIPADDR XXX.

XXX.XXX.XXX

Set ethernet IP address

XXX=0~255

SNETMASK XXX.

XXX.XXX.XXX

Set ethernet net mask

XXX=0~255

SGATEWAY XXX.

XXX.XXX.XXX

Set ethernet gateway

XXX=0~255

SIPMODE N

Set ethernet IP mode

N=STATIC/DHCP

Summary of Contents for CDPW-K1US

Page 1: ...CDPW K1US 8 Button Wall Plate Control Keypad Operation Manual Operation Manual...

Page 2: ......

Page 3: ...erves the right to make improvements to this document and or product at any time and without notice COPYRIGHT NOTICE No part of this document may be reproduced transmitted transcribed stored in a retr...

Page 4: ...n object of any kind into this product through any openings or empty slots in the unit as you may damage parts inside the unit Do not attach the power supply cabling to building surfaces Use only the...

Page 5: ...ont Panel 2 6 2 Rear Panel 3 6 3 Telnet Commands 3 6 4 Software Application 5 6 5 Telnet Control 6 6 6 WebGUI Control 8 6 6 1 Macro Settings 8 6 6 2 Extension Macro 11 6 6 3 Command Settings 11 6 6 4...

Page 6: ...over Ethernet function ease power supply issue without extra DC power burden Further relay outputs design and scheduling function control settings can trigger master switch or any main switch of the i...

Page 7: ...and WebGUI controls Supports PoE function or DC power supply selection US 1 Gang wall plate design with adjustable LED dim light Multiple uses for home hotel room central control or conference room an...

Page 8: ...ns when the connected server Hub support PSE 48v it can be powered without DC supply connection 3 DC 5V Plug the 5V DC power adaptor included in the package and connect to AC wall outlet for power sup...

Page 9: ...l N LEN NO 1 8 N1 0 100 LEDRED N N1 Led red backlight control N LEN NO 1 8 N1 0 100 LEDBLUES N All blue led backlight control N 0 100 LEDREDS N All red led backlight control N 0 100 LEDSHOW N Led dimm...

Page 10: ...t port of an active network system and open the CDPS V2 000 application Click on Find Devices on Network and a list of the devices connected to the Control System will show up Note The default IP sett...

Page 11: ...o access the Telnet control in Windows 7 click on the Start menu and type cmd in the Search field then press enter Under Windows XP go to the Start menu and click on Run type cmd with then press enter...

Page 12: ...to control Type help to list the available commands Note Commands will not be executed unless followed by a carriage return Commands are case sensitive If the IP is changed then the IP Address require...

Page 13: ...gnial illuminate setting There are 6 Macro inserted as default setting for testing the Wall Plate Control System s functionality Click on Macro 1 6 to demonstrate the function of lighting LEDs Macro 1...

Page 14: ...n Add to insert commands Command can be set to control the Wall Plate Control Box SysCMD other devices connected within the same Telnet system Internet area and Relay devices connected through the Rel...

Page 15: ...set its IP and Port number and it is strongly recommand to set the delay time 500ms in order to secure a successful command sending Once the setting is done click on Save change Command set to contro...

Page 16: ...and Settings to insert new commands or delete commands Command under 128 characters including space can be build up to 128 commands command over 128 characters and under 512 characters including space...

Page 17: ...the Macro s Note The scheduling system support up to 48hrs of memory under power blackout after that the system will reset the time automatically back to 2015 01 01 00 00 00 Click on Edit from Repeat...

Page 18: ...13 Click on Edit from Once column to set the macro command s to be activated on a set time only 6 6 5 Network Settings Click on Network Settings to reset the IP Netmask or Gateway address...

Page 19: ...ows IP and login ID password to be reset back to factory default 6 6 7 Time Settings Click on Time Settings to set the system time and to enable disable Daylight Saving Time DST function Simply click...

Page 20: ...15 7 CONNECTION DIAGRAM DC 5V Control Relay Out DC 5V Control Relay Out Router LAN Connection Power Supply Keypad Relay Output Powered Projector Screen...

Page 21: ...imensions 46mm W 35 5mm D 103 5mm H Jack Excluded 46mm W 38mm D 103 5mm H Jack Included Weight 150g Chassis Material Metal Color White Operating Temperature 0 C 40 C 32 F 104 F Storage Temperature 20...

Page 22: ......

Page 23: ......

Page 24: ...Home page http www cypress com tw CYPRESS TECHNOLOGY CO LTD MPM K1US...

Reviews: