Electrical connection during installation must be carried out by
the manufacturer’s service agent or someone with similar profes-
sional qualifications.
The dishwasher must be connected to residual current devices
as per the relevant safety regulations.
The property’s main power switch must be multipole and placed
outside of the installation area to be easily accessible after in-
stalling the dishwasher. Multiway sockets, extension leads or
timers must not be used.
Potential equalisation must be carried out if required when the
machine is installed. There is a potential equaliser on the back
of the machine that must be connected using a lock washer or
a ring terminal.
The manufacturer recommends that the dishwasher is connected
as per the existing design upon delivery. In the event of any
change of electrical cables, terminal sleeves corresponding to
those supplied with the machine should be used. Refer to the
wiring diagram supplied with the machine. In the event of any
change of electrical cables to 1-phase, H05V5V2-F 3x1.0 mm
2
must be used.
Change of electrical cables as well as repairs and maintenance
relating to safety or performance must be carried out by the
manufacturer’s service agent or someone with similar professional
qualifications.
NOTE!
The manufacturer is not responsible for damages caused by
shortcomings in or incorrect electrical installation.
Connection to automatic dosing
system
The dishwasher can be connected to an automatic dosing system
for commercial detergent and rinse aid which simplifies daily use
and reduces the risk of overdosing.
Connection to an automatic dosing system must be carried out
by the system supplier or someone with similar professional
qualifications.
Connect the dosing system to the back of the dishwasher. Always
reinstall protective caps and plugs if the dosing system is discon-
nected.
95
35
34
0-
39
0
[mm]
1 2 3 4
170
1
Connection for detergent (hose diameter 6 mm). Remove the
plug and connect the hose.
2
Connection for rinse aid (hose diameter 4 mm). Remove the
plug and connect the hose.
3
Connection to cable for detergent pulse (230 V).
4
Connection to cable for rinse aid pulse (230 V).
In section Settings on page 35 the process for activating an
automatic dosing system and venting the system is described.
WARNING!
Risk of contact with high voltage! The supplied protective caps
must be fitted on the dishwasher’s cables for the automatic
dosing system during installation and is the dosing system is
disconnected. The protective cap prevents contact with high
voltage and stops water and dirt getting into the wiring.
WARNING!
Note that there are risks involved in handling commercial deter-
gent and rinse aid. Protective gloves and goggles must be
used when handling these products.
Follow the supplier’s safety regulations concerning the handling
and storage of detergent and rinse aid.