Photoresistor
Photoresistor is used to sense the light intensity that VTX
will auto enable infrared LED. Users can adjust the
photosensitive value by yourself.
Tamper Alarm
Enable the Tamper Alarm, if the gravity of VTX changes, the
phone will alarm. The Threshold value is smaller, the faster
the reaction of device.
Wiegand
Cygnus provides two Wiegand protocol. According to the
corresponding wiegand access device to choose the suitable
protocol.
4.4.3 Relay
Sections
Description
Private Key
Import or Export the Private Key template.
Relay
To configure some settings about unlock
Relay Select: VTX support 3 relays
Relay Type: Different locks use different relay types, default
state or invert state. If you connect the Lock in NO
connector, select default state. Otherwise using invert
state.
Relay Delay(sec): Allows door remain “open” for certain
period The range is from 1 to 10 seconds
DTMF Option: VTX support 1
、
2
、
3
、
4 digits DTMF unlock