cyclotest mySense Instructions For Use Manual Download Page 7

EN-12

EN-13

Operating the device

Operating the device

Recalling saved measurement values

The thermometer has a measurement value memory with 30 save 

slots. The measurement values are saved automatically together with 

the date and time of the measurement. The most recently measured 

value is stored in save slot 1; the value measured prior to that is stored 

in save slot 2, and so on. If more than 30 measurements are taken, 

the oldest value (no. 30) is deleted so that the most recent value (no. 

1) can be saved.

The measurement values and lots of additional information are saved 

in the mySense app, where they can be analysed with ease.

You can also recall the last 30 readings directly from the mySense ba-

sal body temperature thermometer. To do so, proceed as follows:

•  With the device switched off, press and hold the 

memory recall button     for at least 5 seconds 

until the      icon appears on the display. The de-

vice switches to memory mode (Figure 1).

•  The most recently meas-

ured value, no. 1, is now 

displayed (Figure 2, Figure 

3). The display switches 

between the measure-

ment value and the year, 

month/day and time. For 

measurement values that have been transferred to the mySense 

app, the symbol   is displayed.

•  By repeatedly pressing the memory recall 

key  , you can call up the previous measure-

ments (no. 2, no. 3 ...).

•  If no measurement values are saved, the fol-

lowing appears on the display (Figure 4):

Figure 3

Figure 2

Figure 1

Figure 4

•  If the device cannot establish a connection, the measurement value 

is stored on the device to be transferred later. The device can tem-

porarily store up to 30 measurement values. The thermometer then 

switches itself off (Figure 12).

Establishing a data connection to the mySense app

The thermometer automatically synchronises the measurement val-

ues, as well as the date and time, to the mySense app after each meas-

urement.

If you want to synchronise the thermometer to the mySense app with-

out performing a temperature measurement, proceed as follows:

•  With the device switched off, press and hold the data transfer but-

ton   for at least 1 second, but no more than 5 seconds, until the 

Bluetooth symbol   appears in the display. If 

you hold down the button for more than 5 

seconds, you will enter memory recall mode.

•  The device now connects to the app via Blue-

tooth (Figure 1).

•  If the connection is successful, the “APP” indi-

cator appears and the display lights up green 

(Figure 2).

Figure 1

Figure 2

If the device cannot connect to the mySense 

app, it switches itself off after 60 seconds. If this 

occurs, check whether Bluetooth is enabled on 

your smartphone and that the mySense app is running, then try again.

Summary of Contents for mySense

Page 1: ...Instructions for use www cyclotest de mySense...

Page 2: ...anging the battery Changing devices Error messages Technical data Customer service Explanation of symbols Disposal 3 4 6 7 7 9 12 13 14 15 16 17 18 19 19 20 21 22 The cyclotest mySense is a medical di...

Page 3: ...d measuring tip can cause injuries Do not bite or bend the sensor This can cause damage and lead to malfunctions The use of this device near mobile phones radios or other strong electromagnetic fields...

Page 4: ...Bluetooth data connection Temperature unit C F Synchronising Battery display Time Date Memory mode Initial device setup You must install the cyclotest mySense app on your smartphone be fore setting u...

Page 5: ...he device cannot connect to the app it switch es off after 60 seconds If this occurs check whether Bluetooth is enabled on your smart phone and that the mySense app is running Now try to establish a c...

Page 6: ...es a temperature that is higher than 37 50 C the display switch es between the temperature and HI fever warning Figure 10 This measurement will not be included in the cyclotest mySense app s cycle cal...

Page 7: ...edly pressing the memory recall key you can call up the previous measure ments no 2 no 3 If no measurement values are saved the fol lowing appears on the display Figure 4 Figure 3 Figure 2 Figure 1 Fi...

Page 8: ...r switching on the device the battery flat indicator Figure 2 appears on the dis play You must insert a new battery before you can take any temperature measure ments Nothing is shown on the display de...

Page 9: ...ry ready Error messages No display after switching on Check whether the bat tery is positioned correctly and the polarity is cor rect If the error persists change the battery Bluetooth connection erro...

Page 10: ...humidity 15 to 95 Battery 1 x CR2032 3 0 V mercury free Battery life approx 400 measurements Data transfer Bluetooth 4 0 LE low energy IP classification IP67 dust tight protection against temporary su...

Page 11: ...our expense in our plant through repair work or replacement delivery of a defect free device The warranty does not cover normal wear and tear of wearing parts or damage caused by failure to observe t...

Page 12: ...haracter istics If you have any additional questions you can call our cyclotest ser vice hotline which is available Monday to Thursday from 8 00am to 5 00pm and Fridays until 4 30pm Your cyclotest adv...

Page 13: ...odifications Reprinting including of extracts is prohibited Copyright 2018 UEBE Medical GmbH UEBE Medical GmbH Zum Ottersberg 9 97877 Wertheim Germany Phone 49 0 93 42 92 40 40 Fax 49 0 93 42 92 40 80...