Operating the device

Operating the device

Open the cyclotest

®

 mySense app and complete the user registration. 

Follow the instructions in the app.

If you already have an account for the cyclotest

®

 mySoul app, you can 

use these details to log in to the cyclotest

®

 mySense app. Your data 

will then be transferred from the mySoul app.

During the registration process, you will be asked to enter an acti-

vation  code  for  the  thermometer.  You  will  find  this  activation  code 

in the packaging of your cyclotest

®

 mySense basal body temperature 

thermometer.

Once you have successfully completed user registration, the Blue-

tooth function on your smartphone will be enabled and the app will 

search for available devices.

Now switch the thermometer on. To do this, 

press and hold the on/off button   for at least 

1 second.

The device switches on and automatically does 

into SET mode, where you can set the date and 

time (Figure 1).

The date and time are synchronised automati-

cally from the mySense app. To do this, the de-

vice connects to the app via Bluetooth (Figure 2).

If the connection is successful, the “APP” indicator 

appears and the display lights up green (Figure 3).

If the device cannot connect to the app, it switch-

es  off  after  60  seconds.  If  this  occurs,  check 

whether Bluetooth is enabled on your smart-

phone and that the mySense app is running. Now 

try to establish a connection again.

Once the device is connected successfully, you will be prompted to 

perform a test measurement. This test measurement is used to en-

sure that the thermometer and app are functioning correctly and is 

not saved.

To perform the test measurement, please follow the instructions in 

the app and refer to the instructions for measuring wake-up temper-

ature starting on page 10.

•  Switch on the device by pressing and holding the on/off button   for 

at least 1 second.

•  The “On” indicator appears on the display (Fig-

ure 1).

•  The device now performs an internal self-test; 

all display elements are displayed (Figure 2).

•  If measurement values have already been 

saved, the most-recently measured value is 

shown in the display with an M (memory). The 

display switches between the measurement 

value and the year, date and time of the meas-

urement (Figure 3).

•  The device now checks whether all previ-

ous measurement values have already been 

transferred to the mySense app. The device 

can temporarily store up to 30 measurements.

Viewing the most-recent measurement value

Checking the transfer status

Temperature measuring

Figure 1

Figure 2

Figure 3

Figure 1

Figure 3

Figure 2

Summary of Contents for mySense

Page 1: ...Instructions for use www cyclotest de mySense...

Page 2: ...anging the battery Changing devices Error messages Technical data Customer service Explanation of symbols Disposal 3 4 6 7 7 9 12 13 14 15 16 17 18 19 19 20 21 22 The cyclotest mySense is a medical di...

Page 3: ...d measuring tip can cause injuries Do not bite or bend the sensor This can cause damage and lead to malfunctions The use of this device near mobile phones radios or other strong electromagnetic fields...

Page 4: ...Bluetooth data connection Temperature unit C F Synchronising Battery display Time Date Memory mode Initial device setup You must install the cyclotest mySense app on your smartphone be fore setting u...

Page 5: ...he device cannot connect to the app it switch es off after 60 seconds If this occurs check whether Bluetooth is enabled on your smart phone and that the mySense app is running Now try to establish a c...

Page 6: ...es a temperature that is higher than 37 50 C the display switch es between the temperature and HI fever warning Figure 10 This measurement will not be included in the cyclotest mySense app s cycle cal...

Page 7: ...edly pressing the memory recall key you can call up the previous measure ments no 2 no 3 If no measurement values are saved the fol lowing appears on the display Figure 4 Figure 3 Figure 2 Figure 1 Fi...

Page 8: ...r switching on the device the battery flat indicator Figure 2 appears on the dis play You must insert a new battery before you can take any temperature measure ments Nothing is shown on the display de...

Page 9: ...ry ready Error messages No display after switching on Check whether the bat tery is positioned correctly and the polarity is cor rect If the error persists change the battery Bluetooth connection erro...

Page 10: ...humidity 15 to 95 Battery 1 x CR2032 3 0 V mercury free Battery life approx 400 measurements Data transfer Bluetooth 4 0 LE low energy IP classification IP67 dust tight protection against temporary su...

Page 11: ...our expense in our plant through repair work or replacement delivery of a defect free device The warranty does not cover normal wear and tear of wearing parts or damage caused by failure to observe t...

Page 12: ...haracter istics If you have any additional questions you can call our cyclotest ser vice hotline which is available Monday to Thursday from 8 00am to 5 00pm and Fridays until 4 30pm Your cyclotest adv...

Page 13: ...odifications Reprinting including of extracts is prohibited Copyright 2018 UEBE Medical GmbH UEBE Medical GmbH Zum Ottersberg 9 97877 Wertheim Germany Phone 49 0 93 42 92 40 40 Fax 49 0 93 42 92 40 80...

Reviews: