4
Version 2.0
13 14 15 16 17
13
14
15
16
17
3-pin DMX input socket
3-pin DMX output socket
Powercon in
Fuse
The head should be locked for transportation- the tilt lock latch (3) and the pan lock latch (4) have to be in the locked
positions. To unlock the head, move these latches to unlock positions before operating the fixture.
5V micro USB port enable user to adjust fixtures' DMX address without connecting to the main power. The screen
will be lit up when connected to the power bank(and not connected to main power).
Installation
Read ‘Safety information’ before installing the fixture
The fixture is designed for indoor use only and must be used in a dry location with adequate ventilation. Ensure that
none of the fixture’s ventilation slots are blocked.
Fasten the fixture to a secure structure or surface. Do not stand it on a surface or leave it where it can be moved
or fall over. If you install the fixture in a location where it may cause injury or damage if it falls, secure it as directed
in this user manual using a securely anchored safety cable that will hold the fixture if the primary fastening method
fails.
Fastening the fixture to a flat surface
The fixture can be fastened to a hard, fixed,
flat
surface that is oriented at any angle. Ensure that the
surface and all fasteners used can support at least 10 times the weight of all fixtures and equipment to
be installed on it.
Fasten the fixture securely. Do not stand it on a surface or leave it where it can be moved or fall over.
If you install the fixture in a location where it may cause injury or damage if it falls, secure it as directed
below with a securely anchored safety cable that will hold the fixture if the primary fastening method fails.
Mounting the fixture on a truss
The fixture can be clamped to a truss or similar rigging structure in any orientation. When installing the
fixture hanging vertically down, you can use an open-type clamp such as a G-clamp. When installing in
any other orientation, you must use a half-coupler clamp that completely encircles the truss chord.
To clamp the fixture to a truss:
1. Check that the rigging structure can support at least 10 times the weight of all fixtures and equipment
to be installed on it.
2. Block access under the work area.
3. Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the mounting
bracket. The bolt used must be M12. It must pass through both mounting bracket legs and be