7
Version 2.0
2. Select the
Fixture Set
tab.
3. Press
Up
or
Down
button and select
Run Mode
and select
Host
.
4. The fixture will run internal programs.
Master-Slave Operation
This function will allow you to link up to 16 units together and operate without a controller. In a Master-
Slave set up one unit will act as the controlling unit and the others will react to the controlling units
programs. Any unit can act as a Master or as a Slave.
1. Using approved DMX data cables, daisy chain your units together via the XLR connector on the rear
of the units.
2. For the Master unit press the
Setting - Fixture set - Run Mode - Host
icon in in the touch screen.
3. For the slave units press the
DMX address
icon in the touch screen. Set the DMX address to 001.
4. The slave units will now follow the Master unit.
Control Menu Map
The control panel on the front of the fixture,
provides access to the system menu and is
where all necessary system adjustments are
made to the fixture. LCD touch screen makes
it very easy to navigate the system menus.
During normal operation, pressing
MENU
button once will access the fixture’s main
menu.
Once in the main menu you can navigate through the different functions and access the sub-menus with
the
UP
,
DOWN
, and
ENTER
buttons.
Once you reach a field that requires adjusting, press the
ENTER
button to activate that field and use
the
UP
and
DOWN
buttons to adjust the field. Pressing the
ENTER
button once more will confirm your
setting.
You may exit the main menu at any time without making any adjustments by pressing the
MENU
button.
The
REV
button makes it quick reverse of the LCD display.
Default settings=
bold
Main Menu
Level 1
Level 2
Level 3
Function
Setting
DMX address
001-512
DMX address setting
Fixture set
DMX Mode
STD
Channel mode, standard - 25CH
BAC
Channel mode, simplified - 20CH
Run Mode
DMX
Control mode, DMX
Host
Control mode, Auto program
Pan Inverse
Close
Pan reverse movement
Open
Tilt Inverse
Close
Tilt reverse movement
Open
Quiet Mode
Close
Theater mode (Fan mode)
Open