background image

6

V1.1

Occupation of the XLR-connection:

1. Group

2. Signal (-)

3. Signal (+)

DMX OUT

1. Group

2. Signal (-)

3. Signal (+)

DMX IN

If you are using controllers with this occupation, you can connect the DMX-output of the controller directly 

with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other 

XLR-outputs, you need to use adapter-cables.

Building a serial DMX-chain:

Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture.

Always connect one output with the input of the next fixture until all fixtures are connected.

DMX-512 connection with DMX terminator:

For installations where the DMX cable has to run a long distance or is in an electrically noisy 

environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in 

preventing corruption of the digital control signal by electrical noise. The DMX terminator is simply an 

XLR plug with a 120 resistor connected between pins 2 and 3, which is then plugged into the output XLR 

socket of the last fixture in the chain.

Caution: 

At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120 Ω 

resistor between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the 

last fixture.

Power connection

Power Requirements

The FR-40F luminaire operates on 100 to 240 volts AC (+/- 10%, auto-ranging). The luminaire contains 

an auto-ranging power supply.

Connection with the mains:

Connect the device to the mains with the enclosed power supply cable.

The occupation of the connection cables as below:

Cable color

Connection

International

Brown 

Live

L

Blue 

Neutral

N

Yellow/green

Earth(Ground)

Operation

The FR-40F can operate in three different modes. In each mode you can run the fixture as a stand alone 

fixture or in a master/slave confiugration. This next section will detail the differences in the operating 

modes.

Addressing

All fixtures should be given a DMX starting address when using a DMX signal, so that the correct fixture

responds to the correct control signals. This digital starting address is the channel number from which 

Summary of Contents for FR-40F

Page 1: ...USER MANUAL FR 40F RGBW super compact LED fresnel...

Page 2: ...re on a truss 5 Securing with a safety cable 5 DMX 512 connection connection between fixtures 5 Power connection 6 Operation 6 Addressing 6 Universal DMX Control 7 Rotary control 7 Zoom 7 Control Menu...

Page 3: ...f the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operat...

Page 4: ...for indoor use only and must be used in a dry location with adequate ventilation Ensure that none of the fixture s ventilation slots are blocked Fasten the fixture to a secure structure or surface Do...

Page 5: ...ord To clamp the fixture to a truss 1 Check that the rigging structure can support at least 10 times the weight of all fixtures and equipment to be installed on it 2 Block access under the work area 3...

Page 6: ...connected between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the chain Caution At the last fixture the DMX cable has to be terminated with a terminator Solder...

Page 7: ...channels of the unit That means changing the settings of one channel will affect only the selected fixture In the case of theFR 40F which is 1 2 3 4 channels fixture If you set for example the addres...

Page 8: ...speed 0 no delay nod 1 Dimmer speed 1 nod 2 Dimmer speed 2 nod 3 Dimmer speed 3 nod 4 Dimmer speed 4 slowest speed Id Id 01 Id 66 ID address setting tEnP 25 100 Fixture temperature UErn Firmware vers...

Page 9: ...be 000 013 Strobe off 014 255 Strobe with speed increasing CH8 Auto program 000 020 no function 021 030 Auto1 031 040 Auto2 041 050 Auto3 051 060 Auto4 061 070 Auto5 071 080 Auto6 081 090 Auto7 091 10...

Page 10: ...els Mode Function Function Control CH1 Red 000 255 0 100 Red dimmer CH2 Green 000 255 0 100 Green dimmer CH3 Blue 000 255 0 100 Blue dimmer CH4 White 000 255 0 100 White dimmer AR2 D 5 Channels Mode F...

Page 11: ...ID12 224 ID35 247 ID58 130 139 ID13 225 ID36 248 ID59 140 149 ID14 226 ID37 249 ID60 150 159 ID15 227 ID38 250 ID61 160 169 ID16 228 ID39 251 ID62 170 179 ID17 229 ID40 252 ID63 180 189 ID18 230 ID41...

Page 12: ...that you may encounter with solutions The fixture does not work no light Check the connection of power and main fuse Be sure the external fuse has not blown Measure the mains voltage on the main conn...