6 Channels Mode

Function

Function Control

CH6

Strobe

000-255: Strobe with speed increasing

HSV

3 Channels Mode

Function

Function Control

CH1

Hue

000-255: 0-100% Hue

CH2

Saturation

000-255: 0-100% 

Saturation

CH3

Value(brightness)

000-255: 0-100% 

Value(brightness)

ID address selection(Stag-11 channels mode)

Each independent DMX address can have up to 66 ID addressed fixtures. An ID address of 0 will activate 

all ID address locations.

CH11 in Stag-12 CH mode is used to select the target ID address.

DMX value

Function

DMX value

Function

DMX

 

value

Function

000-009

ID1-ID66

212

ID23

235

ID46

010-019

ID1

213

ID24

236

ID47

020-029

ID2

214

ID25

237

ID48

030-039

ID3

215

ID26

238

ID49

040-049

ID4

216

ID27

239

ID50

050-059

ID5

217

ID28

240

ID51

060-069

ID6

218

ID29

241

ID52

070-079

ID7

219

ID30

242

ID53

080-089

ID8

220

ID31

243

ID54

090-099

ID9

221

ID32

244

ID55

100-109

ID10

222

ID33

245

ID56

110-119

ID11

223

ID34

246

ID57

120-129

ID12

224

ID35

247

ID58

130-139

ID13

225

ID36

248

ID59

140-149

ID14

226

ID37

249

ID60

150-159

ID15

227

ID38

250

ID61

160-169

ID16

228

ID39

251

ID62

170-179

ID17

229

ID40

252

ID63

180-189

ID18

230

ID41

253

ID64

190-199

ID19

231

ID42

254

ID65

200-209

ID20

232

ID43

255

ID66

210

ID21

233

ID44

211

ID22

234

ID45

Fixture Cleaning

Due to fog residue, smoke, and dust cleaning the internal and external optical lenses and mirror should 

be carried out periodically to optimize light output. Cleaning frequency depends on the environment 

in which the fixture operates (I.e. smoke, fog residue, dust, dew). In heavy club use we recommend 

cleaning on a monthly basis. Periodic cleaning will ensure longevity, and crisp output.

To clean the fixture:

1. 

Disconnect the fixture from power and allow it to cool for at least 10 minutes.

2. 

Vacuum or gently blow away dust and loose particles from the outside of the fixture with low-pressure 

compressed air.

3.  Clean the surfaces by wiping gently with a soft, clean lint-free cloth moistened with a weak detergent 

solution. Do not rub glass surfaces hard: lift particles off with a soft repeated press. Dry with a soft, 

Summary of Contents for FR-40F

Page 1: ...USER MANUAL FR 40F RGBW super compact LED fresnel...

Page 2: ...re on a truss 5 Securing with a safety cable 5 DMX 512 connection connection between fixtures 5 Power connection 6 Operation 6 Addressing 6 Universal DMX Control 7 Rotary control 7 Zoom 7 Control Menu...

Page 3: ...f the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operat...

Page 4: ...for indoor use only and must be used in a dry location with adequate ventilation Ensure that none of the fixture s ventilation slots are blocked Fasten the fixture to a secure structure or surface Do...

Page 5: ...ord To clamp the fixture to a truss 1 Check that the rigging structure can support at least 10 times the weight of all fixtures and equipment to be installed on it 2 Block access under the work area 3...

Page 6: ...connected between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the chain Caution At the last fixture the DMX cable has to be terminated with a terminator Solder...

Page 7: ...channels of the unit That means changing the settings of one channel will affect only the selected fixture In the case of theFR 40F which is 1 2 3 4 channels fixture If you set for example the addres...

Page 8: ...speed 0 no delay nod 1 Dimmer speed 1 nod 2 Dimmer speed 2 nod 3 Dimmer speed 3 nod 4 Dimmer speed 4 slowest speed Id Id 01 Id 66 ID address setting tEnP 25 100 Fixture temperature UErn Firmware vers...

Page 9: ...be 000 013 Strobe off 014 255 Strobe with speed increasing CH8 Auto program 000 020 no function 021 030 Auto1 031 040 Auto2 041 050 Auto3 051 060 Auto4 061 070 Auto5 071 080 Auto6 081 090 Auto7 091 10...

Page 10: ...els Mode Function Function Control CH1 Red 000 255 0 100 Red dimmer CH2 Green 000 255 0 100 Green dimmer CH3 Blue 000 255 0 100 Blue dimmer CH4 White 000 255 0 100 White dimmer AR2 D 5 Channels Mode F...

Page 11: ...ID12 224 ID35 247 ID58 130 139 ID13 225 ID36 248 ID59 140 149 ID14 226 ID37 249 ID60 150 159 ID15 227 ID38 250 ID61 160 169 ID16 228 ID39 251 ID62 170 179 ID17 229 ID40 252 ID63 180 189 ID18 230 ID41...

Page 12: ...that you may encounter with solutions The fixture does not work no light Check the connection of power and main fuse Be sure the external fuse has not blown Measure the mains voltage on the main conn...

Page 13: ...13 V1 1 www cyclopslighting com...

Reviews: