6
Cyclone Canopy Installation - English
MOUNTING HEIGHTS AND CLEARANCE
• The hood should be installed at 28” minimum above the
cooking surface. If pairing your range hood with a gas
stove minimum mounting height must be 30” above the
cooking surface.
WARNING
Minimum mount height between range top to hood bottom should
be no less than 28” for electric or ceramic stoves, and no less than 30”
for gas stoves. The maximum mount height should be no more than
36”. The hood must be installed at the correct mounting height. Hoods
mounted too low could result in heat damage. Hoods mounted too
high, on the other hand, will be less effective and performance may
suffer.
Check your ceiling height and the hood height maximum before
you select your hood.
Hood installation height above cook top is the user’s preference.
The lower the hood is above the cook top the more efficient it will
be in drawing out cooking odors, grease and smoke.
WIRING INSTALLATION
Grounding Instructions
This appliance must be grounded.
This appliance is equipped with a cord having a grounding wire or
with a plug having grounding wire. The grounding wire must be
grounded properly in the junction box or the plug must be plugged
into an outlet that is properly installed and grounded.
1. Connect the power line ground wire to the green ground wire
supplied with the hood.
2. Connect the black power wire to the black wire supplied with
the hood.
3. Connect the white neutral wire to the white wire supplied with
the hood.
Min: 3”
Max. 2 ¾”
Install the Electrical Power Supply
Position the outlet or junction box within the space covered by the
duct cover. Place the outlet or junction box at a maximum distance
of 24” from where the cord exits from the hood. The center of
the outlet or junction box should be positioned at 2 ¾” away from
the center of the future hood location. Make sure this does not
interfere with the mounting area or with the duct cover.
Min:
Ceramic/Electric
28”
Gas
30”
Max:
36”
36”
Green: Ground
White: Neutral
Black: Power
This appliance requires 120V 60Hz electrical supply and connection to an individual properly grounded branch circuit protected
by a circuit breaker or time delay fuse.