background image

3

Cyclone Canopy Installation - English

IMPORTANT SAFETY INSTRUCTIONS

•  This appliance must be installed by a qualified technician.  

•  The manufacturer declines all responsibilities in the event of 

failure to observe the instructions given here for installation, 

maintenance and suitable use of the product. 

•  The manufacturer further declines all responsibility for injury 

due to negligence, and the warranty of the unit automatically 

expires due to improper installation and maintenance. 

WARNING

•  For indoor use only.

•  For general ventilation use only.  Do not use to exhaust hazardous 

or explosive materials or vapors.

•  Two installers are recommended because of the size and 

weight of this hood.

CAUTION

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 

INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer.  

2.  Before servicing or cleaning the unit, switch power off 

at service panel and lock service panel to prevent power 

from being switched on accidentally.  When the service 

disconnecting means cannot be locked, securely fasten a 

prominent warning device to the service panel.

3.  Installation work and electrical wiring must be done by 

qualified persons in accordance with all applicable codes 

and standards, including fire-rated construction.

4.  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue of fuel burning equipment to 

prevent back drafting.  Follow the heating equipment 

manufacturer’s guideline and safety standards as published 

by the local code authorities.

5.  When cutting or drilling into walls or ceilings, be careful 

not to damage existing electrical wiring and other hidden 

utilities. 

6.  To reduce the risk of fire, electric shock and to properly 

exhaust air, ducted fans must always be vented outdoors.  

Do not vent exhaust air into spaces within walls, ceilings, 

attics, crawl spaces, or garages.  Do not connect this fan 

with any solid-state speed control device.

7.  Always keep the duct clear to maintain proper airflow for 

venting.

8.  The bottom of the hood MUST NOT BE LESS than 28” 

and at a suggested maximum of 36” above cooktop for 

best capture of cooking impurities.  For a gas range, the 

bottom of the hood MUST NOT BE LESS than 30” above 

cooktop.

WARNING

TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:

1.  Never leave the range unattended at high settings.

2.  Always turn hood ON when cooking at high heat or when 

flaming food.

3.  Use proper pan size.  Always use cookware appropriate for 

the size of the surface element.

4.  Keep fan, filters and grease laden surfaces clean.  Clean 

ventilating fans frequently.  Do not allow grease to accumulate 

on fan or filter.

5.  Use HIGH setting on hood only when necessary.

6.  Don’t leave hood unattended when cooking.

7.  To reduce the risk of fire, use only metal ductwork.

8.  This unit must be grounded.

9.  Not for outdoor use.

WARNING

•  Do not repair or replace any part of this appliance unless 

specifically recommended in this book.  All other service 

should be performed by a qualified technician. 

•  The hood motor has a thermal overload that will 

automatically shut off the motor if it becomes overheated.  

The motor will restart.  If the motor continually shuts off 

and restarts, contact the Cyclone service department.  

Ensure that the hood is mounted at the recommended 

mounting height. 

•  This product may have sharp edges.  Be careful to avoid 

cuts and abrasions during installation and cleaning. 

WARNING

Summary of Contents for SC322

Page 1: ...iring and installation must be in accordance with CEC NEC and local electrical codes READ AND SAVE THESE INSTRUCTIONS Wall Mount and Island Range Hoods SC B 500 SC B 501 SC B 502 SC B 503 SC510 SC B 5...

Page 2: ...2 Cyclone Canopy Installation English...

Page 3: ...e existing electrical wiring and other hidden utilities 6 To reduce the risk of fire electric shock and to properly exhaust air ducted fans must always be vented outdoors Do not vent exhaust air into...

Page 4: ...Wall Mount Installation Tools and Materials Required 7 Wall Mount Installation Parts Supplied 7 Wall Mount Hood Installation 8 Island Installation Tools and Materials Required 9 Island Installation Pa...

Page 5: ...educer is used install a long reducer instead of a pancake reducer If turns and transitions are required install them as far away from the opening as possible and as far apart between two as possible...

Page 6: ...t be grounded This appliance is equipped with a cord having a grounding wire or with a plug having grounding wire The grounding wire must be grounded properly in the junction box or the plug must be p...

Page 7: ...ws WALL MOUNT INSTALLATION TOOLS AND MATERIALS REQUIRED Electrical drill or ratchet driver drill bit for drilling pilot holes 1 drill bit for drilling electrical wiring access hole if applicable Phill...

Page 8: ...6 round adapter if not preinstalled 8 Remove the filters from the hood 9 Hang hood onto screws and hand tighten If possible use extra screws to further secure the hood to the wall from inside the hoo...

Page 9: ...ATERIALS REQUIRED Electrical drill or ratchet driver drill bit for drilling pilot holes 1 drill bit for drilling electrical wiring access hole if applicable Phillips screwdriver 2 or driver bit Wire s...

Page 10: ...construction codes and standards WARNING Install Mounting Bracket 1 Modify ceiling structure at hood location Install 2 4 cross framing between ceiling joists using ceiling mounting bracket dimension...

Page 11: ...g Screws 3 Slide the lower and upper chimney flues over the installed mounting bracket and have a second person hold it to the ceiling 4 Attach the hood to mounting bracket using six screws three per...

Page 12: ...SS STAINLESS STEEL STAINLESSSTEEL GLASS STAINLESS STEEL STAINLESSSTEEL GLASS CONTROLS PUSH BUTTON PUSH BUTTON PUSH BUTTON PUSH BUTTON PUSH BUTTON SPEED LEVELS 3 3 3 3 3 DELAY OFF YES YES YES YES YES L...

Page 13: ...yclone Canopy Installation English 3 1 4 6 29 or 35 9 1 8 17 10 Min 27 Max 45 6 7 11 13 6 3 1 4 FRONT SIDE TOP BACK 8 9 18 30 36 1 10 27 Max 45 17 SPECIFICATIONS Alito Collection Wall Mount Model SC B...

Page 14: ...14 Cyclone Canopy Installation English 3 1 4 6 23 9 1 8 17 10 Min 27 Max 45 6 7 11 13 6 3 1 4 FRONT SIDE TOP BACK 8 9 18 23 1 11 27 Max 45 17 SPECIFICATIONS Alito Collection Wall Mount Model SC50024...

Page 15: ...Canopy Installation English SPECIFICATIONS Alito Collection Wall Mount Model SC B 501 FRONT SIDE TOP BACK 7 10 Min 23 Max 44 Min 23 Max 44 29 or 35 23 19 17 7 9 12 13 5 3 6 11 21 11 10 19 30 36 2 17...

Page 16: ...Cyclone Canopy Installation English FRONT SIDE TOP BACK 7 9 12 5 3 6 7 11 10 29 or 35 19 13 Min 23 Max 44 23 17 1 10 11 21 2 30 36 19 23 Max 44 SPECIFICATIONS Alito Collection Wall Mount Model SC B 5...

Page 17: ...yclone Canopy Installation English SPECIFICATIONS Alito Collection Wall Mount Model SC B 503 FRONT SIDE TOP BACK 7 9 12 5 3 6 7 11 10 29 or 35 19 13 3 4 Min 23 Max 44 23 17 1 10 11 21 2 30 36 19 23 Ma...

Page 18: ...8 Cyclone Canopy Installation English SPECIFICATIONS Alito Collection Wall Mount Model SC510 FRONT SIDE TOP BACK 7 9 12 5 3 6 7 11 10 29 or 35 19 13 Min 23 Max 44 1 5 6 14 1 10 11 21 30 36 19 23 Max 4...

Page 19: ...yclone Canopy Installation English SPECIFICATIONS Alito Collection Wall Mount Model SC B 513 FRONT SIDE TOP BACK 7 9 13 5 3 6 7 11 10 29 or 35 19 15 Min 24 Max 45 16 1 24 1 1 1 10 11 21 30 36 19 24 Ma...

Page 20: ...20 Cyclone Canopy Installation English SPECIFICATIONS Alito Collection Wall Mount Model SC B 514 FRONT SIDE TOP BACK 7 9 13 5 3 6 7 11 10 29 or 35 19 15 Min 23 Max 44 2 2 10 11 21 30 36 19 23 Max 44...

Page 21: ...21 Cyclone Canopy Installation English FRONT SIDE TOP BACK 7 9 13 5 3 6 7 11 10 23 19 15 Min 23 Max 44 2 2 10 11 21 24 19 23 Max 44 SPECIFICATIONS Alito Collection Wall Mount Model SC51424...

Page 22: ...yclone Canopy Installation English SPECIFICATIONS Alito Collection Island Model SI B 323 FRONT SIDE TOP FRONT WITHOUT FLUE 12 10 29 or 35 23 Min 26 Max 49 2 3 6 3 3 13 14 6 8 2 10 12 23 26 Max 49 30 3...

Page 23: ...Cyclone Canopy Installation English FRONT SIDE TOP FRONT WITHOUT FLUE 3 6 35 12 1 10 23 6 Min 30 Max 53 18 3 3 11 8 8 10 12 23 36 6 30 Max 53 23 1 SPECIFICATIONS Alito Collection Island Model SI B 52...

Page 24: ...Canopy Installation English FRONT SIDE TOP FRONT WITHOUT FLUE 8 8 12 10 Min 26 Max 49 Min 26 Max 49 35 23 23 18 14 12 3 6 3 3 23 12 10 23 36 2 18 26 Max 49 SPECIFICATIONS Alito Collection Island Mode...

Page 25: ...yclone Canopy Installation English FRONT SIDE TOP FRONT WITHOUT FLUE 12 12 10 35 23 13 Min 25 Max 48 23 18 1 3 6 3 3 8 8 10 12 23 25 Max 48 1 36 23 18 SPECIFICATIONS Alito Collection Island Model SI B...

Page 26: ...yclone Canopy Installation English FRONT SIDE TOP FRONT WITHOUT FLUE 12 10 29 or 35 23 Min 26 Max 49 2 3 6 3 3 13 14 6 8 2 10 12 23 26 Max 49 30 36 23 SPECIFICATIONS Alito Collection Island Model SI B...

Page 27: ...27 Cyclone Canopy Installation English SPECIFICATIONS Alito Collection Island Model SI530 FRONT SIDE TOP FRONT WITHOUT FLUE 11 10 35 23 Min 25 Max 48 1 3 6 3 3 12 13 21 8 8 1 10 12 23 36 23 25 Max 48...

Page 28: ...Cyclone Canopy Installation English FRONT SIDE TOP FRONT WITHOUT FLUE 3 6 3 3 11 35 Min 26 Max 49 1 1 10 12 15 24 23 18 8 8 1 1 10 12 23 36 23 26 Max 49 SPECIFICATIONS Alito Collection Island Model SI...

Page 29: ...29 Cyclone Canopy Installation English 7 9 13 5 3 6 7 11 10 23 or 29 19 15 Min 23 Max 44 1 3 4 FRONT SIDE TOP BACK 1 75 10 11 21 24 30 19 23 Max 44 SPECIFICATIONS PRO Collection Wall Mount Model SC322...

Page 30: ...30 Cyclone Canopy Installation English 3 6 29 or 35 9 2 8 17 12 Min 30 Max 47 6 7 13 14 6 3 FRONT SIDE TOP BACK 9 18 30 36 12 30 Max 47 17 2 8 SPECIFICATIONS PRO Collection Wall Mount Model SCB711...

Page 31: ...31 Cyclone Canopy Installation English 12 35 16 10 19 Min 23 Max 44 15 1 5 3 6 7 7 9 12 13 FRONT SIDE TOP BACK 10 11 21 2 36 19 23 Max 44 SPECIFICATIONS PRO Collection Wall Mount Model SC712...

Page 32: ...32 Cyclone Canopy Installation English 3 6 29 or 35 10 1 8 21 12 Min 26 Max 40 7 9 10 15 6 3 FRONT SIDE TOP BACK 14 30 36 12 26 Max 40 21 10 8 1 SPECIFICATIONS PRO Collection Wall Mount Model SC B 715...

Page 33: ...llection Wall Mount Model SCB717 7 3 4 9 9 16 5 1 4 3 1 4 6 7 1 2 13 1 4 11 3 4 10 1 2 25 3 4 or 30 3 4 16 23 3 4 Min 28 Max 46 1 2 1 3 4 29 1 2 or 35 1 2 16 16 13 1 4 25 1 4 FRONT SIDE TOP BACK 10 18...

Page 34: ...y Installation English 7 9 5 3 6 7 13 11 10 35 16 23 Min 28 Max 46 1 16 19 13 25 FRONT SIDE TOP BACK 10 18 16 36 11 28 Max 46 Distance from front panel to wall 16 SPECIFICATIONS PRO Collection Wall Mo...

Page 35: ...35 Cyclone Canopy Installation English 7 9 13 5 3 6 7 11 10 29 or 35 19 15 Min 23 Max 44 1 FRONT SIDE TOP BACK 1 3 4 10 11 21 23 Max 44 30 36 19 SPECIFICATIONS PRO Collection Wall Mount Model SC720...

Page 36: ...Cyclone Canopy Installation English SPECIFICATIONS PRO Collection Wall Mount Model SC B 722 7 9 13 5 3 6 7 11 10 29 or 35 19 15 Min 23 Max 44 1 3 4 FRONT SIDE TOP BACK 1 75 10 11 21 30 36 19 23 Max 4...

Page 37: ...37 Cyclone Canopy Installation English SPECIFICATIONS PRO Collection Wall Mount Model SC72224 7 9 13 5 3 6 7 11 10 23 19 15 Min 23 Max 44 1 3 4 FRONT SIDE TOP BACK 1 75 10 11 21 24 19 23 Max 44...

Page 38: ...nge defective part Servicing may be required The unit vibrates 1 The motor is not secured 1 Tighten the motor in place 2 Damaged blower wheel 2 Replace the blower wheel Servicing may be required 3 The...

Page 39: ...ol pads that can scratch the surface of the machine Use non abrasive stainless steel polish to buff out the luster and grain Scrub lightly The stainless steel filters trap residue and grease from cook...

Page 40: ...essories for ducting c natural wear of the finish of the products or wear caused by improper maintenance use of corrosive and abrasive cleaning products d products or parts which have been subject to...

Reviews: