background image

10

Cyclone Canopy Installation - English

Measure Installation Height

Determine the required distance between the ceiling and the top of 

the blower box (D) based upon ceiling height (C), desired height of 

hood above cooktop (A) and unit height (B):

 D=C-A-B

The height D is the installation height of the mounting bracket 

(Figure 3) .  If the installation height D is less than 22”, the mounting 

bracket and duct covers may need to be cut.  The duct cover needs a 

clean cut and must to be cut from bottom end sides for both inside 

and outside pieces.  For optimal clearance, the minimum mounting 

should be 30” above the cooking surface.

C/L

A

C

D

B

Blower Top Box

Range Hood Bottom

•  When building framework, always follow all applicable 

construction codes and standards.

WARNING

Install Mounting Bracket

1.  Modify ceiling structure at hood location.  Install 2 × 4 

cross framing between ceiling joists using ceiling mounting 

bracket dimension (Figure 4).  The framework must be sized 

to support the total weight of the hood. 

2.  Finish ceiling surface.  Be sure to mark the location of the 

ceiling joists and cross framing.  Bring house wiring through 

finished ceiling.

10 ½”

11 ¼”

9 ⅝”

8 ¾”

ø 6 ¾”

3 ⅜”

4 ⅜”

1 ⅜”

Upper Mounting

Bracket

Ceiling Joists

Cross Framing

6” Round 

Ductwork

ISLAND HOOD INSTALLATION

•  At least two installers are required due to the weight and 

size of the hood.

•  This hood should be installed to a finished ceiling.

•  Turn off power circuit at the service panel before wiring 

this unit.

•  All electrical work must be done by a qualified electrician 

in accordance with all applicable codes and standards.  

This range hood must be properly grounded.

CAUTION

Figure 4.

Figure 5.

Summary of Contents for AB14

Page 1: ...nd local electrical codes READ AND SAVE THESE INSTRUCTIONS Wall Mount and Island Range Hoods SC B 300 SC B 500 HC400 AW00 SC B 301 SC B 501 HC401 AW01 SC B 502 ALW02 SC B 503 SC510 ALW10 SC B 513 HC413 SC B 514 HC414 ALW14 AW14 AB14 SCB516 SCB316 SC B 519 SC B 319 SI B 323 SI B 520 SI B 521 SI B 522 SI B 523 SI530 SI531 SI532 SCB711 SC712 SC B 715 ALW15 SCB717 SCB718 SC720 SC B 322 SC B 722 ALW22 ...

Page 2: ...2 Cyclone Canopy Installation English ...

Page 3: ...ack drafting Follow the heating equipment manufacturer s guideline and safety standards as published by the local code authorities 5 When cutting or drilling into walls or ceilings be careful not to damage existing electrical wiring and other hidden utilities 6 To reduce the risk of fire electric shock and to properly exhaust air ducted fans must always be vented outdoors Do not vent exhaust air i...

Page 4: ... Wall Mount Installation Tools and Materials Required 7 Wall Mount Installation Parts Supplied 7 Wall Mount Hood Installation 8 Island Installation Tools and Materials Required 9 Island Installation Parts Supplied 9 Island Hood Installation 10 Canopy Hoods Specifications 12 Troubleshooting 13 Control Panel 14 Maintenance 14 Cyclone Range Hoods Limited Warranty 15 ...

Page 5: ...educer If turns and transitions are required install them as far away from the opening as possible and as far apart between two as possible CAUTION 6 round ductwork must be used to maintain maximum air flow efficiency with motors of 450 CFM or greater If the use of any size ducting is less than 6 the warranty is automatically voided Theventingductmustgohorizontallyorverticallyuptothe outside wall ...

Page 6: ...st be grounded This appliance is equipped with a cord having a grounding wire or with a plug having grounding wire The grounding wire must be grounded properly in the junction box or the plug must be plugged into an outlet that is properly installed and grounded 1 Connect the power line ground wire to the green ground wire supplied with the hood 2 Connect the black power wire to the black wire sup...

Page 7: ...ONLY 2 Bottom Chimney Screws WALLMOUNTINSTALLATION TOOLSANDMATERIALSREQUIRED Electrical drill or ratchet driver drill bit for drilling pilot holes 1 drill bit for drilling electrical wiring access hole if applicable Phillips screwdriver 2 or driver bit Wire stripper or cutter Tape measure Aluminum foil tape and or duct tape Electrical supplies for wiring i e marrets electrical tape Hammer Jigsaw o...

Page 8: ...l 6 round adapter if not preinstalled 8 Remove the filters from the hood 9 Hang hood onto screws and hand tighten If possible use extra screws to further secure the hood to the wall from inside the hood 10 Install 6 round duct over the adapter connect it with the venting duct coming from the wall or ceiling Use metal foil duct tape to seal the joint 11 Install electrical connection Turn on the hoo...

Page 9: ...ALLATION TOOLS AND MATERIALS REQUIRED Electrical drill or ratchet driver drill bit for drilling pilot holes 1 drill bit for drilling electrical wiring access hole if applicable Phillips screwdriver 2 or driver bit Wire stripper or cutter Tape measure Aluminum foil tape and or duct tape Electrical supplies for wiring i e marrets electrical tape Hammer Jigsaw or saber saw Drywall stud if applicable ...

Page 10: ... construction codes and standards WARNING Install Mounting Bracket 1 Modify ceiling structure at hood location Install 2 4 cross framing between ceiling joists using ceiling mounting bracket dimension Figure 4 The framework must be sized to support the total weight of the hood 2 Finish ceiling surface Be sure to mark the location of the ceiling joists and cross framing Bring house wiring through f...

Page 11: ...pe Mounting Screws 3 Slide the lower and upper chimney flues over the installed mounting bracket and have a second person hold it to the ceiling 4 Attach the hood to mounting bracket using six screws three per side Figure 7 5 Slide the lower and upper chimney flues down on top of the hood Install the electrical connection and connect the duct to the rough in duct work in the ceiling Seal the joint...

Page 12: ...AINLESSSTEEL GLASS STAINLESS STEEL STAINLESSSTEEL GLASS STAINLESS STEEL STAINLESSSTEEL GLASS CONTROLS ELECTRONIC PUSH BUTTON ELECTRONIC PUSH BUTTON ELECTRONIC PUSH BUTTON ELECTRONIC PUSH BUTTON ELECTRONIC PUSH BUTTON ELECTRONIC PUSH BUTTON SPEED LEVELS 3 3 3 3 3 3 DELAY OFF YES YES YES YES YES YES LIGHTING 2 1 5W LED SI323 4 1 5W LED 2 1 5W LED 2 1 5W LED 2 1 5W LED 2 1 5W LED 2 1 5W LED SI523 4 1...

Page 13: ...utton seized 2 Loosen the switch mounting screws from back of the switch 3 The control panel or motherboard is defective 3 Changedefectivepart Servicingmayberequired The unit vibrates 1 The motor is not secured 1 Tighten the motor in place 2 Damaged blower wheel 2 Replace the blower wheel Servicing may be required 3 The hood is not secured in place 3 Check the installation of the hood 4 Venting du...

Page 14: ...Cleaning Clean with warm soapy water and a clean cloth Do not use corrosive or abrasive detergent or steel wool pads that can scratch the surface of the machine Use non abrasive stainless steel polish to buff out the luster and grain Scrub lightly The stainless steel filters trap residue and grease from cooking The filters should never have to be replaced but should be cleaned thoroughly every 30 ...

Page 15: ...ries for ducting c natural wear of the finish of the products or wear caused by improper maintenance use of corrosive and abrasive cleaning products d products or parts which have been subject to freight damage misuse negligence accident or any other circumstances beyond the control of The Company The warranty will be automatically void if any of the following apply i Commercial use of the product...

Reviews: