Manual of ALT382
8
Install & Test
6
、
Photoelectric Sensor Installation: 1. Screw the photoelectric clip on the printhead stand. 2. Screw the
photoelectric sensor on the clip or other position as request, or use different types of sensor. When
using solvent-base inks, the sensor shall be fixed in front of printhead.
7
、
Power connection: 1. Check the machine is grounded. 2. Link the power cord to the socket behind
the host machine in 110v AC power. 3. After indicator lighted up, please wait for 15 seconds to access
the system.
8
、
Printing Test: 1. Put the ink cartridge into the ink system in correct position. 2. Remove the cap of the
printhead, and squeeze the ink cartridge to drain out the air and cleaner until no bubbles. 3. Clean
up the surface by blotting-paper. 4. Tested by blank papers (with more details see page 26).
9
、
Product moving position: the speed of production line shall be slower than the speed of printing. A guide
plate can be installed to receive the exactly position of product which has passed the printhead. In
principal, the distance between product and print head more closely, the printing result will be
better.
10
、
Production Line adjustment: more details see page10.