Shenzhen Zhiyong Electronics Co., Ltd
4
4.
Technical Specification
Frequency range
EM5080L
9kHz to 30MHz
EM5080M
9kHz to 500MHz
EM5080B
9kHz to 1GHz
EM5080C
9kHz to 3GHz
Level
Maximum RF level (CW)
RF attenuation≥20dB
RF pre-Amplifier off
30dBm(=1W)
Maximum pulse voltage
RF attenuation≥20dB
150V
Resolution ratio bandwidth
Analyzer mode
20kHz,50kHz,100kHz,200kHz,500kHz,1MHz,
5MHz
Receiver mode
200Hz, 9kHz, 120kHz
(
–6dB)
1MHz (pulse bandwidth)
Preselector
Could be turned off in analyzer
Mode
15 tunnel fixed filter
Preset amplifier
Can be turn on/off
9kHz to 3GHz, 20dB gain, uniformed
Test time
Receiver mode
1ms to 1s
Detector
Receiver mode
Peak, quasi-peak, average value
Displayed average
noise level
Receiver mode, uniformed, Average detector, RF attenuation 0dB
Preset Amplifier off.
30MHz<f<1GHz,
bandwidth 120kHz
< 15dBμV
1GHz<f<3GHz,
bandwidth 1MHz
< 25dBμV
Preset Amplifier on
30MHz<f<1GHz,
bandwidth 120kHz
< 0dBμV
1GHz<f<3GHz,
bandwidth 1MHz
< 10dBμV
All uncertainty
9kHz≤f<3GHz
1.5dB
Power consumption
<100W
(
220V/50Hz
)
CYBERTEK