background image

2

 

 

 

Important safety warnings 

This manual contains important instructions that should be followed during 
installation and maintenance of the UPS and batteries. Please read and follow all 
instructions carefully during installation and operation of the unit. Read this 
manual thoroughly before attempting to unpack, install, or operate. 

CAUTION! 

The UPS must be connected to an AC power outlet with fuse or 

circuit breaker protection. 

DO NOT 

plug the machine into an outlet that is not 

grounded. If you need to de-energize this equipment, turn off and unplug the UPS. 

CAUTION! DO NOT USE FOR MEDICAL OR LIFE SUPPORT 
EQUIPMENT! 

CyberPower Systems does not sell products for life support or 

medical applications. DO NOT use in any circumstance that would affect 
operation or safety of any life support equipment, with any medical applications, or 
patient care. 

CAUTION! 

The battery can energize hazardous live parts inside even when 

the AC input power is disconnected. 

CAUTION! 

To prevent the risk of fire or electric shock, install in a temperature 

and humidity controlled indoor area, free of conductive contaminants. (Please see 
specifications for acceptable temperature and humidity range). 

CAUTION! 

To reduce the risk of electric shock, do not remove the cover, 

except to service the battery. No user serviceable parts inside, except for the 
battery. 

CAUTION! 

To avoid electrical shock, turn off the unit and unplug it from the AC 

power source before servicing the battery or installing a computer component. 

CAUTION! 

DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of 

fire, do not use with or near aquariums. Condensation from the aquarium can 
come in contact with metal current contacts and cause the machine to short out. 

CAUTION! 

DO NOT USE WITH LASER PRINTERS! The power demands of 

laser printers are too large for a UPS. 

 

UNPACKING 

Inspect the UPS upon receipt. The box should contain the following: 
UPS Unit; (1) User’s Manual for UPS; (2) Rack mount Brackets; (2) Stands; (1) 
Telephone Cable (1) PowerPanel Business Edition Software CD; (1) User’s 
Manual; (2) Serial Interface Cable (DB-9); (1) Serial-to-USB cable; (1) Warranty 
Registration Card.

 

 

HARDWARE INSTALLATION GUIDE 

1.  Your new UPS may be used immediately upon receipt. However, 

recharging 

the battery for at least four hours 

is recommended to insure that the 

battery’s maximum charge capacity is achieved. Charge loss may occur 
during shipping and storage. To recharge the battery, simply leave the unit 
plugged into an AC outlet. The unit will charge in both the on as well as the off 
position. 

2.  If you wish to use the software, connect the enclosed serial interface cable to 

the serial port on the UPS and an open serial port on the computer. If you 
would like to use USB interface, please connect the USB adapter with the 

Summary of Contents for PR2200

Page 1: ...User s Manual Professional Rack Mount UPS PR1500 PR2200 K01 1500S0A 04...

Page 2: ...MITED WARRANTY 12 CONFORMANCE APPROVALS 15 Thank you for purchasing a CyberPower Systems Product To enjoy all the features and benefits of this Uninterruptible Power System UPS please read and follow...

Page 3: ...ttery No user serviceable parts inside except for the battery CAUTION To avoid electrical shock turn off the unit and unplug it from the AC power source before servicing the battery or installing a co...

Page 4: ...ords If used the extension cord must be rated for 15 Amps 6 Depress the power switch to turn the unit on The power on indicator light will illuminate If an overload is detected an audible alarm will s...

Page 5: ...is supplying power to the battery power supplied outlets AVR Indicator This LED indicates that the UPS is operating in automatic voltage regulation mode When the LED is illuminated continuously it ind...

Page 6: ...f connected equipment during a power failure Individual Backup Power for Critical Load The UPS provides two battery powered surge protected and AVR outlets for the most critical connected equipment an...

Page 7: ...h PowerPanel software installed is unable to exhibit any control over the UPS When there is a power failure the Primary computer will start to shutdown after a user controlled delay Once the Primary c...

Page 8: ...local ordinances regarding proper disposal of batteries CAUTION Do not open or mutilate the batteries Release electrolyte is harmful to the skin and eyes and may be toxic CAUTION A battery can presen...

Page 9: ...en remove the cover Disconnect the black and red cable Remove the four retaining screws Pull the battery pack out from the unit Slide a new battery pack into the unit Assemble the screws cover cable a...

Page 10: ...flash On off Set Long beeps Overload Turn the UPS off and unplug at least one piece of equipment from the UPS Wait 5 seconds reset the circuit breaker and restart the UPS Off Off Off On Up Long beep...

Page 11: ...seconds and then turn the UPS on The unit is not connected to an AC outlet The unit must be connected to a 110 120V 50 60Hz outlet The battery is worn out Contact CyberPower about replacement batteri...

Page 12: ...RJ45 One In One Out Physical Toatal of UPS Receptacles 7 Maximum Dimensions in 2U Rack 2 17 1 x 15 3 x 3 5 Weight lbs 58 58 Battery Sealed Maintenance Free Lead Acid Battery 12Vdc 7AHx4 12Vdc 9AHx4 T...

Page 13: ...ment that was connected to the Product and damaged because of the failure of the Product What Is the Period of Coverage This warranty covers the Product for three years and connected equipment for as...

Page 14: ...eplaced due to the failure of the Product or any data that is lost as a result of the failure or the restoration of data or records or the reinstallation of software 2 This Warranty does not cover or...

Page 15: ...e Limited Warranty and Connected Equipment Guarantee CyberPower excludes any liability for direct indirect special incidental or consequential damages whether for damage to or loss of property EXCEPT...

Page 16: ...and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this...

Page 17: ...16...

Page 18: ...erpowersystems com E mail sales cyberpowersystems com CyberPower Europe CyberPower Systems B V Flight Forum 3545 5657DW Eindhoven The Netherlands Tel 31 0 40 2348170 Fax 31 0 40 2340314 Website http e...

Reviews: