RJ45/DB9 Serial Port 

Connection Cable

Cable Ties / Qty. 20

10 (M3x6) Cord Retention Tray 

Mounting Screws 

(Includes two spares)

6 (M5x12) Screws / 6 Washers 

(Includes two spares for each)

10 (Flat Head M4x8) Bracket Mounting 

Screws (Includes two spares)

PDU

Mounting Brackets x 2

Registration
Card

User Manual     Registration Card         CD

Cord Retention Trays x 2

Documentation

Before using, please check to ensure the package contains all the items shown above. If there 
are missing parts, please contact CyberPower technical support at [email protected] or call 
1-877-297-6937 when you are US customers. For European customers, please contact 
CyberPower at [email protected].

Safety Precautions

Read the following before installing or operating the 

Power Distribution Units (PDU):

Use only the supplied hardware to attach the mounting brackets.

The PDU must be plugged into a three-wire, grounded outlet on a circuit 

that is protected by a fuse or circuit breaker. For PDU15xxxxx series, 

please use 15A circuit protector. For PDU20xxxxx series, please use 20A 

circuit protector. For PDU30xxxxx series, please use 30A circuit protector. 

Connection to any other type of power outlet may result in a shock hazard.

Do not use extension cords or adapters with this PDU.

Never install a PDU, or associated wiring or equipment, during a

lightning storm.

Ensure that the power cord, plug, and socket are in good condition.

CAUTION!!

To prevent the risk of fire or electric shock, this PDU should be installed in a temperature 
and humidity controlled indoor area free of conductive contaminants. Do not install this 
PDU where excessive moisture or heat is present.

Introduction

Package Contents 
(For 2U Series) 

CyberP

ower

Reliability

. Quality

. Value.

R

User's Manual

3

4

Front panel description

NEMA Type

1

2

3

4

5

6

7

8

Select

KW

Volts

Amps

- Normal

- Warning

- Overload

Tx/Rx

Link

Reset

YU0-0000026-00

PDU20SWHVIEC8FNET

A. Power Cord

B. AC Output Outlets

C. Current Level

D. Input Voltage

E. Power

F. Load Indicator

G. Ethernet Port

H. Tx/Rx Indicator

I.  Link Indicator

J. Outlet Indicator

  (switched series only)

K. Serial/ ENVIROSENSOR Port 

  (RJ45 modular port)

L. Select Button

M. PDU Status Screen

N. Reset Button

Rear panel description

Technical Specification

Product Features (1U 15A Series)

IEC Type

1

2

3

4

5

6

7

8

Select

KW

Volts

Amps

- Normal

- Warning

- Overload

Tx/Rx

Link

Reset

PDU15SWHVIEC8FNET

A

A. External Site Ground

Model Name

PDU15SW8FNET

PDU15SWHVIEC8FNET

PDU15M8FNET

PDU15MHVIEC8FNET

Input

  Nominal Voltage

100-120V

200-240V

100-120V

200-240V

  Frequency
  Derated Input
  Current

12A

12A(UL)/10A(CE)

12A

12A(UL)/10A(CE)

  Plug Type

NEMA 5-15P

IEC-320 C14

NEMA 5-15P

IEC-320 C14

  Power Cord Type

SR (14 AWG)

Socket

SR (14 AWG)

Socket

  Power Cord
  Length

12 ft/3.65 m

10 ft/3.05 m

12 ft/3.65 m

10 ft/3.05 m

Output

  Nominal Voltage

100-120V

200-240V

100-120V

200-240V

  Derated Output
  Current

12A

12A(UL)/10A(CE)

12A

12A(UL)/10A(CE)

  Outlet Type

NEMA 5-15R

IEC-320 C13

NEMA 5-15R

IEC-320 C13

  Outlet Number

Networking
  

Protocol Support

  

Connectivity

Physical

  Dimension
  (H x W x D)

Environmental

  Humidity
  Altitude
  Temperature

Safety Approvals

  Certifications

UL 60950-1

CSA C22.2

FCC Class A

 UL 60950-1

CSA C22.2

CE, FCC Class A

UL 60950-1

CSA C22.2

FCC Class A

 UL 60950-1

CSA C22.2

CE, FCC Class A

Warranty

  Product Warranty

Switched Series (1U 15A)

Monitored Series (1U 15A)

8

50/60Hz

3 years

RJ45

1.75" x 17.05" x 4.41"/44mm x 433mm x 112mm

TCP/IP, UDP, DHCP, SNMP, HTTP

0 to 95% Non-condensing

14700 ft/4500 m

32

 to 104

/0

 to 40

A

G

I

E

H

B

D

F

J

N

L

M

A

K

C

G

I

E

H

B

D

F

J

N

L

M

A

K

C

Summary of Contents for PDU15M8FNET

Page 1: ...Power Distribution Unit User Manual www CPSww com K01 0000181 02 ...

Page 2: ...U with Keyhole Mount 15 Electrical Installation 15 Network Installation 16 Operation 17 Metered Readout 17 Basic Operation 17 PDU Status Screen 17 Current Level 17 Input Voltage 17 Power 17 IP Address 17 Outlet Control Switched series only 17 LED Reversal 0U series only 17 Environmental Monitoring optional 18 LED Indicators 18 Device Reset 18 Remote Management 18 Unattended Automatic Shutdown 19 F...

Page 3: ... Bracket Mounting Screws Includes two spares PDU RJ45 DB9 Serial Port Connection Cable Cable Ties Qty 20 16 Outlets Qty 30 24 Outlets Cord Retention Tray Mounting Screws M3x6 Qty 10 for 16 Outlets Qty 14 for 24 Outlets Includes two spares 6 Flat Head M4x4 Bracket Mounting Screws Includes two spares Mounting Brackets x 2 Cord Retention Trays Qty 2 16 Outlets Qty 3 24 Outlets 6 M5x12 Screws 6 Washer...

Page 4: ... For 2U Series CyberPower Reliab ility Qualit y Value R User s Manual 3 4 Front panel description NEMA Type 1 2 3 4 5 6 7 8 Select KW Volts Amps Normal Warning Overload Tx Rx Link Reset YU0 0000026 00 PDU20SWHVIEC8FNET A Power Cord B AC Output Outlets C Current Level D Input Voltage E Power F Load Indicator G Ethernet Port H Tx Rx Indicator I Link Indicator J Outlet Indicator switched series only ...

Page 5: ...d Input Current P 0 2 5 A M E N P 0 2 5 A M E N P 0 2 5 L A M E N P 0 2 5 L A M E N Power Cord Type SR 12AWG Socket SR 12 AWG Socket Power Cord Length 12 ft 3 65 m 10 ft 3 05 m 12 ft 3 65 m 10 ft 3 05 m Output Nominal Voltage 100 120V 200 240V 100 120V 200 240V Outlet Type NEMA 5 20R IEC 320 C13 NEMA 5 20R IEC 320 C13 Outlet Number Networking Protocol Support Connectivity Physical Dimension H x W ...

Page 6: ...21 22 23 BANK 1 BANK 1 BANK 2 BANK 2 BANK 1 20A BANK 2 20A Output 100 120VAC 50 60HZ 24A MAX 8 16 24 A C F H J D E G I L N M O B K B K B K Model Name PDU20SWVT24FNET PDU20SWVHVT24FNET PDU20MVT24FNET PDU20MVHVT24FNET Input Nominal Voltage 100 120V 200 240V 100 120V 200 240V Frequency Plug Type NEMA L5 20P NEMA L6 20P NEMA L5 20P NEMA L6 20P Power Cord Type Power Cord Length Output Nominal Voltage 1...

Page 7: ...kets 2 to the PDU If you plan on attaching the Cord Retention Tray to the PDU you will need to use the LONG Mounting Brackets 2 Step 2 PDU Mounting Use the supplied Washers 4 and Screws 4 to secure the PDU to your existing rack system B K A G H C I J L N F D M O E B K A G H C I J L N F D M O E Model Name PDU30SWT16FNET PDU30SWHVT16FNET PDU30MT16FNET PDU30MHVT16FNET Input Nominal Voltage 100 120V 2...

Page 8: ... Use the provided Cable Ties to fasten each cord to the Cord Retention Tray Step 3 Cord Retention Tray Installation optional Attach the Cord Retention Tray to the PDU with the 8 supplied Cord Retention Tray Mounting Screws For 2U Model Step 1 Mounting Bracket Installation Use the provided Mounting Bracket Screws 8 to attach the Mounting Brackets 2 to the PDU Step 2 PDU Mounting Use the supplied Wa...

Page 9: ...p 2 PDU Mounting Use the supplied Washers 2 and Screws 2 to secure the PDU to your existing rack system Vertical Installation 1U 0U Model Only For 1U Model Step 1 Mounting Bracket Installation Use the provided Mounting Bracket Screws 8 to attach the SHORT Mounting Brackets 2 to the PDU Step 3 Cord Retention Tray Installation optional Attach the Cord Retention Tray to the PDU with the supplied Cord...

Page 10: ...ommended Power Device Network Utility 1 Use the included PDU Software Installation CD to install the Power Device Network Utility program 2 Open the Power Device Network Utility software Start Power Device Network Utility 3 Highlight the PDU device from the list and select Edit and Setup device Assisted Setup from the menu 4 Configure the IP Address Subnet Mask and Gateway Address to match your ne...

Page 11: ...witched series only LED Reversal 0U series only CyberPower PDUs along with the environment sensor ENVIROSENSOR provide the function of temperature and humidity monitoring in a server closet and or datacenter remotely To connect the PDU with ENVIROSENSOR use the RJ45 Ethernet Cable Plug one end into the Serial ENVIROSENSOR port on the PDU and the other end into the RJ45 port on the ENVIROSENSOR as ...

Page 12: ...is successful by checking the Firmware version on the System About webpage Note Please do not turn the PDU off when processing the Firmware upgrade 19 20 Operation Troubleshooting Frequently Ask Questions FAQ Q What do I do if I ve lost the Administrator username and or password A Resetting the PDU will set the username and password back to system default Please see the Device Reset section to res...

Page 13: ...on Blue Book or another a third party valuation guide or eBay craigslist or other source to establish that amount Our liability is limited to the amount if any stated in the Technical Specifications Who pays for shipping We pay when we send items to you you pay when you send items to us What Are Some Things This Warranty Does Not Cover 1 This Warranty does not cover any software that is damaged or...

Page 14: ... the default firewall alert message is shown as Figure 5 You need to allow the Power Device Network Utility access through the firewall Figure 3 Power Device Network Utility Getting Started The Power Device Network Utility scans the network for devices with MAC addresses that match CyberPower network hardware Once found the device s can then be figured with a specific IP address subnet mask and ga...

Page 15: ...all power devices Step 3 Authentication Enter the user name and password of the PDU device at the Authentication menu Shown in Figure 7 Note The default username is cyber and the default password is cyber Figure 7 Authentication screen Advanced Settings Timeout Settings The Timeout Setting Shown in Figure 8 Edit Timeout Settings is used to specify the wait time when scanning for network PDU device...

Reviews: