background image

●  

 Product Registration

Thank you for purchasing a CyberPower product. Prompt product registration entitles 

coverage under the Limited Warranty, and also allows the opportunity to be notified of 

product enhancements, upgrades, and other announcements.

Registration is quick and easy at www.cpsww.com/support/warranty-registration.html

    CyberPower International

Feel free to contact our Tech Support department with installation, troubleshooting, or 

general product questions.

CyberPower North America

Phone: (952)403-9500  Toll-free: (877)297-6937

Email: [email protected]

Web: www.CPSww.com

Add: 4241 12th Avenue E., Suite 400 Shakopee, MN 55379

Hours of Operation: Monday-Friday 8:00 AM-5:00 PM (CST)

CyberPower Europe

Email: [email protected]

Web: www.cpsww.eu

    Limited Warranty

Read the following terms and conditions carefully before using the CyberPower PDU 

series. By using the Product, you consent to be bound by and become a party to the 

terms and conditions of this Limited Warranty. If you do not agree to the terms and 

conditions of this Warranty, you should return the Product for a full refund prior to 

using it.

Who Is Providing This Warranty?

CyberPower Systems (USA), Inc. /CyberPower Europe ("CyberPower") provides this 

Limited Warranty.

What Does This Warranty Cover?

This warranty covers defects in materials and workmanship in the Product under 

normal use and conditions.

What is the Period of Coverage?

CyberPower provides a 3-Year warranty to the original purchaser who owns 

the Product.

Who Is Covered?

This warranty only covers the original purchaser.

Coverage ends if you sell or otherwise transfer the Product.

How Do You Get Service?

1.  You can use the contact information mentioned above for instructions.

2.  When you contact CyberPower, identify the Product, the Purchase Date, and the 

item(s) of Connected Equipment. Have information on all applicable insurance or 

other resources of recovery/payment that are available to the Initial Customer and 

Request a Claim Number.

3.  You must provide a purchase receipt (or other proof of the original purchase) and 

provide a description of the defect. 

What Will We Do To Correct Problems?

CyberPower will inspect and examine the Product. 

If the Product is defective in material or workmanship, CyberPower will repair or 

replace it at CyberPower's expense, or, if CyberPower is unable to or decides not to 

repair or replace the Product (if defective) within a reasonable time, CyberPower will 

refund to you the full purchase price you paid for the Product (purchase receipt 

showing price paid is required).

If it appears that our Product failed to protect any equipment plugged into it, we will 

also send you forms for making your claim for the connected equipment. We will 

repair or replace the equipment that was damaged because of the failure of our 

Product or pay you the fair market value (NOT REPLACEMENT COST) of the 

equipment at of the time of the damage. We will use Orion Blue Book, or another a 

third-party valuation guide, or eBay, craigslist, or other source to establish that 

amount. Our liability is limited to the amount, if any, stated in the Technical 

Specifications.

Who pays for shipping?

We pay when we send items to you; you pay when you send items to us. 

What Are Some Things This Warranty Does Not Cover?

1.  This Warranty does not cover any software that is damaged or needs to be 

     replaced due to the failure of the Product or any data that is lost as a result of the 

     failure or the restoration of data or records, or the reinstallation of software.

2.  This Warranty does not cover or apply to: misuse, modification, operation or 

     storage outside environmental limits of the Product or the equipment connected 

     to it, nor for damage while in transit or in storage, nor if there has been improper 

     operation or maintenance, or use with items not designed or intended for use 

     with the Product, such as laser printers, appliances, aquariums, medical or life 

     support devices, etc.

21

22

Customer Service & Warranty

Customer Service & Warranty

What are the Limitations?

1.  This Warranty does not apply unless the Product and the equipment that was 

     connected to it were connected to properly wired and grounded outlets (including 

     compliance with electrical and safety codes of the most current electrical code), 

     without the use of any adapters or other connectors.

2.  The Product must have been plugged directly into the power source and the 

     equipment connected to the Product must be directly connected to the Product 

     and not "daisy-chained" together in serial fashion with any extension cords, 

     another Product or device similar to the Product, surge suppressor, or power tap. 

     Any such installation voids the Limited Warranty.

3.  The Product and equipment connected to it must have been used properly in a 

     suitable and proper environment and in conformance with any license, instruction 

     manual, or warnings provided with the Product and the equipment connected to it.

4.  The Product must have been used at all times within the limitations on the 

     Product's VA capacity.

5.  The sole and exclusive remedies of the Initial Customer are those 

     provided by this Warranty.

Appendix A-Hyper Terminal

Hyper Terminal software can be used for basic PDU configuration. It utilizes a 

text-based interface and menu system. Navigation through the interface is done by 

typing the number of the menu option and pressing the Enter key. Note: The 

session will timeout and logout after 3 minutes of inactivity. Menu options are shown 

below:

[Main Menu]

1.  Network Settings

2.  System Configuration

3.  Account Settings

4.  Configure System to Default

5.  Logout

[Network Setting]

Physical MAC Address: 00-0C-15-40-08-A9

1.  System IP: 192.168.24.20

2.  Subnet Mask: 255.255.255.0

3.  Default Gateway: 192.168.24.254

4.  DHCP: Enable

5.  Http Port: 80

6.  Http Access: Enable

[System Configuration]

1.  Date (mm/dd/yyyy) : 11/11/2011

2.  Time (hh:mm:ss): 17:17:25

3.  Name:PDU20SW8FNET

4.  Contact: Administrator

5.  Location: Server Room

[Account Setting]

1.  Administrator

2.  Viewer(Web Only)

[Configure System to Default]

Sure to Configure System to Default

1.  Yes

0.  NO

Summary of Contents for PDU15M8FNET

Page 1: ...Power Distribution Unit User Manual www CPSww com K01 0000181 02 ...

Page 2: ...U with Keyhole Mount 15 Electrical Installation 15 Network Installation 16 Operation 17 Metered Readout 17 Basic Operation 17 PDU Status Screen 17 Current Level 17 Input Voltage 17 Power 17 IP Address 17 Outlet Control Switched series only 17 LED Reversal 0U series only 17 Environmental Monitoring optional 18 LED Indicators 18 Device Reset 18 Remote Management 18 Unattended Automatic Shutdown 19 F...

Page 3: ... Bracket Mounting Screws Includes two spares PDU RJ45 DB9 Serial Port Connection Cable Cable Ties Qty 20 16 Outlets Qty 30 24 Outlets Cord Retention Tray Mounting Screws M3x6 Qty 10 for 16 Outlets Qty 14 for 24 Outlets Includes two spares 6 Flat Head M4x4 Bracket Mounting Screws Includes two spares Mounting Brackets x 2 Cord Retention Trays Qty 2 16 Outlets Qty 3 24 Outlets 6 M5x12 Screws 6 Washer...

Page 4: ... For 2U Series CyberPower Reliab ility Qualit y Value R User s Manual 3 4 Front panel description NEMA Type 1 2 3 4 5 6 7 8 Select KW Volts Amps Normal Warning Overload Tx Rx Link Reset YU0 0000026 00 PDU20SWHVIEC8FNET A Power Cord B AC Output Outlets C Current Level D Input Voltage E Power F Load Indicator G Ethernet Port H Tx Rx Indicator I Link Indicator J Outlet Indicator switched series only ...

Page 5: ...d Input Current P 0 2 5 A M E N P 0 2 5 A M E N P 0 2 5 L A M E N P 0 2 5 L A M E N Power Cord Type SR 12AWG Socket SR 12 AWG Socket Power Cord Length 12 ft 3 65 m 10 ft 3 05 m 12 ft 3 65 m 10 ft 3 05 m Output Nominal Voltage 100 120V 200 240V 100 120V 200 240V Outlet Type NEMA 5 20R IEC 320 C13 NEMA 5 20R IEC 320 C13 Outlet Number Networking Protocol Support Connectivity Physical Dimension H x W ...

Page 6: ...21 22 23 BANK 1 BANK 1 BANK 2 BANK 2 BANK 1 20A BANK 2 20A Output 100 120VAC 50 60HZ 24A MAX 8 16 24 A C F H J D E G I L N M O B K B K B K Model Name PDU20SWVT24FNET PDU20SWVHVT24FNET PDU20MVT24FNET PDU20MVHVT24FNET Input Nominal Voltage 100 120V 200 240V 100 120V 200 240V Frequency Plug Type NEMA L5 20P NEMA L6 20P NEMA L5 20P NEMA L6 20P Power Cord Type Power Cord Length Output Nominal Voltage 1...

Page 7: ...kets 2 to the PDU If you plan on attaching the Cord Retention Tray to the PDU you will need to use the LONG Mounting Brackets 2 Step 2 PDU Mounting Use the supplied Washers 4 and Screws 4 to secure the PDU to your existing rack system B K A G H C I J L N F D M O E B K A G H C I J L N F D M O E Model Name PDU30SWT16FNET PDU30SWHVT16FNET PDU30MT16FNET PDU30MHVT16FNET Input Nominal Voltage 100 120V 2...

Page 8: ... Use the provided Cable Ties to fasten each cord to the Cord Retention Tray Step 3 Cord Retention Tray Installation optional Attach the Cord Retention Tray to the PDU with the 8 supplied Cord Retention Tray Mounting Screws For 2U Model Step 1 Mounting Bracket Installation Use the provided Mounting Bracket Screws 8 to attach the Mounting Brackets 2 to the PDU Step 2 PDU Mounting Use the supplied Wa...

Page 9: ...p 2 PDU Mounting Use the supplied Washers 2 and Screws 2 to secure the PDU to your existing rack system Vertical Installation 1U 0U Model Only For 1U Model Step 1 Mounting Bracket Installation Use the provided Mounting Bracket Screws 8 to attach the SHORT Mounting Brackets 2 to the PDU Step 3 Cord Retention Tray Installation optional Attach the Cord Retention Tray to the PDU with the supplied Cord...

Page 10: ...ommended Power Device Network Utility 1 Use the included PDU Software Installation CD to install the Power Device Network Utility program 2 Open the Power Device Network Utility software Start Power Device Network Utility 3 Highlight the PDU device from the list and select Edit and Setup device Assisted Setup from the menu 4 Configure the IP Address Subnet Mask and Gateway Address to match your ne...

Page 11: ...witched series only LED Reversal 0U series only CyberPower PDUs along with the environment sensor ENVIROSENSOR provide the function of temperature and humidity monitoring in a server closet and or datacenter remotely To connect the PDU with ENVIROSENSOR use the RJ45 Ethernet Cable Plug one end into the Serial ENVIROSENSOR port on the PDU and the other end into the RJ45 port on the ENVIROSENSOR as ...

Page 12: ...is successful by checking the Firmware version on the System About webpage Note Please do not turn the PDU off when processing the Firmware upgrade 19 20 Operation Troubleshooting Frequently Ask Questions FAQ Q What do I do if I ve lost the Administrator username and or password A Resetting the PDU will set the username and password back to system default Please see the Device Reset section to res...

Page 13: ...on Blue Book or another a third party valuation guide or eBay craigslist or other source to establish that amount Our liability is limited to the amount if any stated in the Technical Specifications Who pays for shipping We pay when we send items to you you pay when you send items to us What Are Some Things This Warranty Does Not Cover 1 This Warranty does not cover any software that is damaged or...

Page 14: ... the default firewall alert message is shown as Figure 5 You need to allow the Power Device Network Utility access through the firewall Figure 3 Power Device Network Utility Getting Started The Power Device Network Utility scans the network for devices with MAC addresses that match CyberPower network hardware Once found the device s can then be figured with a specific IP address subnet mask and ga...

Page 15: ...all power devices Step 3 Authentication Enter the user name and password of the PDU device at the Authentication menu Shown in Figure 7 Note The default username is cyber and the default password is cyber Figure 7 Authentication screen Advanced Settings Timeout Settings The Timeout Setting Shown in Figure 8 Edit Timeout Settings is used to specify the wait time when scanning for network PDU device...