background image

Model List:

Basic Series:

PDU15B8R

PDU15B10R

PDU15B12R

PDU20B8R

PDU20B10R

PDU20B12R

PDU20BT8R

PDU20BT10R

PDU20BT12R

PDU15B2F8R

PDU15B2F10R

PDU15B2F12R

PDU15B4F8R

PDU15B4F10R

PDU15B4F12R

PDU15B6F8R

PDU15B6F10R

PDU15B6F12R

PDU20B2F8R

PDU20B2F10R

PDU20B2F12R

PDU20B4F8R

PDU20B4F10R

PDU20B4F12R

PDU20B6F8R

PDU20B6F10R

PDU20B6F12R

PDU20BT2F8R

PDU20BT2F10R

PDU20BT2F12R

PDU20BT4F8R

PDU20BT4F10R

PDU20BT4F12R

PDU20BT6F8R

PDU20BT6F10R

PDU20BT6F12R

Metered Series:

PDU15M2F8R

PDU15M2F10R

PDU15M2F12R

PDU20M2F8R

PDU20M2F10R

PDU20M2F12R

PDU20MT2F8R

PDU20MT2F10R

PDU20MT2F12R

Basic Series (0U):

PDU15BV14F

PDU15BV16F

PDU15BV20F

PDU15BV28F

PDU15BV32F

PDU20BV14F

PDU20BV16F

PDU20BV20F

PDU20BV28F

PDU20BV32F

PDU20BVT14F

PDU20BVT16F

PDU20BVT20F

PDU20BVT28F

PDU20BVT32F

Metered Series (0U):

PDU15MV20F

PDU15MV26F

PDU15MV32F

PDU20MV20F

PDU20MV26F

PDU20MV32F

PDU20MVT20F

PDU20MVT26F

PDU20MVT32F

PDU Naming Convention:

1. Amperage:          

2. Series:

                 

3. Rack Space:                 

4. Input Voltage:                

5. Plug Type:

                     

6. Outlet Number Front     

7. Outlet Number Rear      

8. Network Management   

PDU   XX   M  V  HV   T   F   R   NET

1

2 3

4

5

6

7

8

Amperage – 15A, 20A, 30A         

B: =Basic           M: =Metered   

SW: = Switched

NULL: =Horizontal      V:= Vertical

NULL: =120V  HV:= High Voltage – 208V to 250V

NULL: =NEMA 5-15P / 5-20P 

T: = Twist (NEMA L5-L6 Plug) 

IEC:= (IEC C14/C20)

Number of Outlets followed by F – Example 8F

Number of Outlets followed by R – Example 8R

NET

 

For information on Cyberpower products, visit www.cyberpower.com

1

Summary of Contents for PDU15B10R

Page 1: ...Power Distribution Unit User s Manual...

Page 2: ...n Vertical Installation with Brackets Vertical Installation Keyhole Mounts 0U models only Cord Retention Tray installation Meter Configuration Electrical Installation Troubleshooting 6 Product Feature...

Page 3: ...V16F PDU15BV20F PDU15BV28F PDU15BV32F PDU20BV14F PDU20BV16F PDU20BV20F PDU20BV28F PDU20BV32F PDU20BVT14F PDU20BVT16F PDU20BVT20F PDU20BVT28F PDU20BVT32F Metered Series 0U PDU15MV20F PDU15MV26F PDU15MV...

Page 4: ...equipment during a lightning storm 5 Check that the power cord plug and socket are in good condition 6 CAUTION To prevent the risk of fire or electric shock this PDU should be installed in a temperat...

Page 5: ...only Step 1 Mounting bracket installation Install the screws M4 X 6 in holes diagonal from each other Step 2 PDU Mounting Install the PDU using fasteners compatible with the rack For information on C...

Page 6: ...Mounting bracket installation Attach the Vertical Mounting Brackets to the PDU with the 4 supplied Bracket Mounting Screws M4 X 6 Step 2 PDU Mounting Install the PDU using fasteners compatible with t...

Page 7: ...al and vertical installations Attach the Cord Retention Tray to the PDU with the 4 supplied Cord Retention Tray Mounting Screws M3 X 6 Tighten the Cord Retention Tray with the screw on it Use the Cabl...

Page 8: ...as outlined in the Specifications section In order to determine your total load simply add up the amperage of your devices and ensure that it does not exceed the unit s capacity Troubleshooting Probl...

Page 9: ...nput Voltage Max current 15 A Circuit Breaker 15 A Plug Type NEMA 5 15P NEMA 5 20P NEMA L5 20P Output Voltage Current 15 A Outlet Type NEMA 5 15R Indicators LED Indicators Meter Readout Physical Envir...

Page 10: ...PDU20BT2F8R PDU20BT2F10R PDU20BT2F12R PDU20BT4F8R PDU20BT4F10R PDU20BT4F12R PDU20BT6F8R PDU20BT6F10R PDU20BT6F12R Input Voltage Max current 15 A Circuit Breaker 15 A Plug Type NEMA 5 15P NEMA 5 20P NE...

Page 11: ...x Current 15 A Circuit Breaker 15 A Plug Type NEMA 5 15P NEMA 5 20P NEMA L5 20P Power Cord Length Output Voltage Current 15 A Outlet Type NEMA 5 15R Fiters Protection EMI RFI Filtration Surge Suppress...

Page 12: ...Breaker 15 A Plug Type NEMA 5 15P NEMA 5 20P NEMA L5 20P Output Voltage Current 15 A Outlet Type NEMA 5 15R Indicators LED Indicators Meter Readout Physical Environmental Humidity Altitude Temperatur...

Page 13: ...5 A Circuit Breaker 15 A Plug Type NEMA 5 15P NEMA 5 20P NEMA L5 20P Output Voltage Current 15 A Outlet Type NEMA 5 15R Indicators LED Indicators Meter Readout Physical Environmental Humidity Altitude...

Page 14: ...only covers the original purchaser Coverage ends if you sell or otherwise transfer the Product How Do You Get Service 1 Call us at 877 297 6937 or write to us at Cyber Power Systems USA Inc 4241 12th...

Page 15: ...ectrical code without the use of any adapters or other connectors 2 The Product must have been plugged directly into the power source and the equipment connected to the Product must be directly connec...

Page 16: ...K01 0000511 00 Cyber Power Systems Inc www cyberpower com...

Reviews: