IMPORTANT SAFETY INSTRUCTIONS

 

 

 

This manual contains important instructions. Please read and follow all instructions carefully during installation and operation of the 
unit. Read this manual thoroughly before attempting to unpack, install, or operate the UPS. 

 

CAUTION!   

The  UPS  must  be  connected  to  a  grounded  AC 

power  outlet  with  fuse  or  circuit  breaker  protection.  DO  NOT 
plug the UPS into an outlet that is not grounded. If you need to 
power-drain this equipment, turn off and unplug the unit.

 

CAUTION!   

The  battery  can  power  hazardous  components 

inside the unit, even when the AC input power is disconnected.

 

CAUTION!   

The  UPS  should  be  placed  near  the  connected 

equipment and easily accessible. 

CAUTION!   

To prevent the risk of fire or electric shock, install 

in  a  temperature  and  humidity  controlled  indoor  area,  free  of 
conductive  contaminants.  (Please  see  specifications  for 
acceptable temperature and humidity range).

 

CAUTION!    (No  User  Serviceable  Parts):

  Risk  of  electric 

shock, do not remove cover. No user serviceable parts inside. 
Refer servicing to qualified service personnel.

 

CAUTION!    (Non-Isolated  Battery  Supply): 

Risk  of  electric 

shock,  battery  circuit  is  not  isolated  from  AC  power  source; 
hazardous  voltage  may  exist  between  battery  terminals  and 
ground. Test before touching.

 

CAUTION!   

To  reduce  the  risk  of  fire,  connect  the  UPS  to  a 

branch  circuit  with  10  amperes  (OLS1000  /  OLS1500)  /  16 
amperes 

(OLS2000/ 

OLS3000) 

maximum 

over-current 

protection in accordance to CE requirement.

 

CAUTION!   

The AC outlet where the UPS is connected should 

be close to the unit and easily accessible. 

CAUTION!   

Please  use  only  VDE-tested,  CE-marked  mains 

cable, (e.g. the mains cable of your equipment), to connect the 
UPS to the AC outlet.

 

CAUTION!   

Please  use  only  VDE-tested,  CE-marked  power 

cables to connect any equipment to the UPS. 

CAUTION!   

When  installing  the  equipment,  ensure  that  the 

sum  of  the  leakage  current  of  the  UPS  and  the  connected 
equipment does not exceed 3.5mA.

 

CAUTION! 

The OLS1000 / OLS1500 / OLS2000 / OLS3000 / 

Battery  module  models  are  only  qualified  maintenance 
personnel may carry out installations.

 

CAUTION!   

Do  not  unplug  the  unit  from  AC  Power  during 

operation,  as  this  will  invalidate  the  protective  ground 
insulation. 

CAUTION!   

To  avoid  electric  shock,  turn  off  and  unplug  the 

unit before installing the input/output power cord with a ground 
wire.  Connect  the  ground  wire  prior  to  connecting  the  line 
wires! 

CAUTION!   

Do not use an improper size power cord as it may 

cause damage to your equipment and cause fire hazards. 

CAUTION!   

Wiring must be done by qualified personnel.

 

CAUTION!    DO  NOT  USE  FOR  MEDICAL  OR  LIFE 
SUPPORT  EQUIPMENT!

    Under  no  circumstances  this  unit 

should  be  used  for  medical  applications  involving  life  support 
equipment and/or patient care.

 

CAUTION!    DO  NOT  USE  WITH  OR  NEAR  AQUARIUMS!

   

To  reduce  the  risk  of  fire,  do  not  use  with  or  near  aquariums.   
Condensation  from  the  aquarium  can  come  in  contact  with 
metal electrical contacts and cause the machine to short out. 

CAUTION!   

Do  not  dispose  of  batteries  in  fire  as  the  battery 

may explode. 

CAUTION!   

Do  not  open  or  mutilate  the  battery,  released 

electrolyte is harmful to the skin and eyes. 

CAUTION!   

A battery can present a risk of electric shock and 

high  short  circuit  current.  The  following  precaution  should  be 
observed when working on batteries 

1.  Remove watches, rings or other metal objects. 

2.  Use tools with insulated handles. 

CAUTION!   

The  unit  has  a  dangerous  amount  of  voltage. 

When  the  UPS  indicators  is  on,  the  units  may  continue  to 
supply  power  thus  the  unit’s  outlets  may  have  a  dangerous 
amount  of  voltage  even  when  it’s  not  plugged  in  to  the  wall 
outlet. 

CAUTION!   

Make  sure  everything  is  turned  off  and 

disconnected  completely  before  conducting  any  maintenance, 
repairs or shipment. 

CAUTION!   

Connect  the  Protection  Earth  (PE)  safety 

conductor before any other cables are connected. 

WARNING!    (Fuses): 

To  reduce  the  risk  of  fire,  replace  only 

with the same type and rating of fuse. 

DO  NOT  INSTALL  THE  UPS  WHERE  IT  WOULD  BE 
EXPOSED  TO  DIRECT  SUNLIGHT  OR  NEAR  A  STRONG 
HEAT SOURCE! 

DO  NOT  BLOCK  OFF  VENTILATION  OPENINGS  AROUND 
THE HOUSING! 

DO  NOT  CONNECT  DOMESTIC  APPLIANCES  SUCH  AS 
HAIR DRYERS TO UPS OUTPUT SOCKETS! 

SERVICING OF BATTERIES SHOULD BE PERFORMED OR 
SUPERVISED 

BY 

PERSONNEL 

KNOWLEDGE 

OF 

BATTERIES  AND  THE  REQUIRED  PRECAUTIONS.  KEEP 
UNAUTHORIZED PERSONNEL AWAY FROM BATTERIES!

 

Summary of Contents for OLS1000E

Page 1: ...User s Manual OLS1000E EXL OLS1500E EXL OLS2000E EXL OLS3000E EXL CyberPower Systems Inc www cpsww com K01 C000036 00 ...

Page 2: ...rsonnel may carry out installations CAUTION Do not unplug the unit from AC Power during operation as this will invalidate the protective ground insulation CAUTION To avoid electric shock turn off and unplug the unit before installing the input output power cord with a ground wire Connect the ground wire prior to connecting the line wires CAUTION Do not use an improper size power cord as it may cau...

Page 3: ...Copyright 2012 CyberPower Systems Inc UNPACKING 2 UPS User s manual Phone line USB communication cable Input power cord Output power cords x2pcs PowerPanel Business Edition software CD ...

Page 4: ...quipment from the outlets Make sure your equipment carries a load current within the unit s safe range refer to the technical specifications 6 This UPS is equipped with an auto charge feature When the UPS is plugged into an AC outlet the battery will automatically charge even when the unit is switched off 7 To maintain an optimal battery charge leave the UPS plugged into an AC outlet at all times ...

Page 5: ...us programmable parameters 7 USB port This is a connectivity port which allows communication and control between the UPS and the connected computer It is recommended to install the PowerPanel Business Edition Agent software on the PC Server connected with the USB cord 8 Surge Protected Communication Ports RJ 45 RJ 11 These ports are used to protect standard RJ 45 RJ 11 based products ADSL LAN Phon...

Page 6: ...o daisy chain the next Battery module Remove the connector cover for access 2 On board Replaceable Fuse Cover Replaceable fuse is accessible from the rear panel It must be done by qualified personnel 3 Output Connector Use this output Connector to connect the Battery module to the Power module or to the next Battery module BPSE36V45A BPSE72V45A ...

Page 7: ...MODULE Step 1 Loosen the two screws to remove the battery cable retention bracket of the power module Step 2 Use the battery cable of the Battery module to connect the Battery module to the Power module Step 3 Rotate the battery cable retention bracket and tighten the two screws to fix battery cable ...

Page 8: ...ery module to the Power module using battery cable Step 2 Loosen the two screws to remove the battery cable retention bracket of the 1 st battery module Step 3 Use the battery cable to connect the 2 nd Battery module to the 1 st Battery module Step 4 Rotate the battery cable retention bracket and tighten the two screws to fix battery cable ...

Page 9: ...capacity This meter displays the approximate charge level in 20 increments of the UPS s internal battery During a blackout or severe brownout the UPS switches to battery power the BATTERY icon appears and the charge level decreases MUTE This icon appears whenever the UPS is in silent mode The alarm does not beep during silent mode until the battery reaches low capacity SCHEDULE Users can setup the...

Page 10: ...tery voltage is too low to DC start UPS 57 EPO Off Missing the EPO connection 58 Fan Fail The ventilation hole has been covered or the fans can t work BUTTON OPERATION Button Operation Description ON Press this button to turn on UPS OFF Press this button to turn off UPS ENTER Press this button to scroll up in the LCD menu Press this button simultaneously for 5 seconds to disable or enable the alar...

Page 11: ...Displays the Estimated Percentage of Battery Capacity ESTIMATED RUN TIME XX X Min Hr Displays the Estimated Run Time with battery TIME TO SHUT DOWN XX X Min Hr Displays the Time Delay to Shutdown UPS TIME TO TURN ON XX X Min Hr Displays the Time Delay to Restart UPS LCD SETTINGS CONFIGURATION There are 7 UPS settings that can be configured by the user 1 Press the ESC button to activate the setting...

Page 12: ...rn on off by the ROO port If ROO port is disconnected UPS will be turned off If ROO port is connected UPS will be turned on when the utility is normal UPS cannot detect the numbers of external battery automatically so manual input from user is necessary Note The manual settings programming mode can ONLY be invoked while UPS is in Bypass mode or Standby mode To make UPS on Standby mode connect util...

Page 13: ...chains wrist watches and rings CAUTION Do not open or mutilate the batteries Electrolyte fluid is harmful to the skin eyes and may be toxic CAUTION To avoid electric shock turn off and unplug the UPS from the wall receptacle before servicing the battery CAUTION Only use tools with insulated handles Do not lay tools or metal parts on top of the UPS or battery terminals Replacement Batteries Please ...

Page 14: ...5 Configurable UPS Outlets 4 IEC C13 2 2 IEC C13 1 Terminal Block 2 2 IEC C13 1 IEC C19 1 Terminal Block Protection Surge Protection IEC 61000 4 5 Level 4 Phone Network Protection RJ11 RJ45 One In One Out Overload Protection Line Mode 105 110 Overload warning only No shutdown 110 120 Warning transfer to bypass after 60s 120 Transfer to bypass immediately Battery Mode 105 110 Overload warning only ...

Page 15: ...ment Software PowerPanel Business Edition Physical Dimensions D W H 15 51 x 5 94 x 8 86in 394 151 225 mm D W H 16 38 x 7 72 x 13 28in 416 196 337 mm Net Weight 28 9 17 0lbs 13 1 7 7Kg 33 7 17 2lbs 15 3 7 8Kg 52 5 26 9lbs 23 8 12 2Kg 62 2 27 8lbs 28 2 12 6Kg Safety Conformance Approvals CE ...

Page 16: ...down UPS and turn off AC input 2 Contact CyberPower for repair EPO OFF Missing the EPO connection Check the EPO connection Fault Over Temperature High ambient temperature 1 Shut down UPS Restart UPS to Check the fan for operation and if the ventilation hole has been covered 2 Contact CyberPower for repair Output Short Output short circuit 1 Shut down UPS 2 Your attached equipment may have problems...