TECHNICAL SPECIFICATIONS

 

 

 

9

 

 

*200V are derated by 20%, 208 V are derated by 10% for OL10KRT2UTFHWIOR / OL10KRT2UTFHWIO

 

 

SAFETY PRECAUTIONS

 

CAUTION!   

Before connecting to the UPS, check that the input voltage into the UPS is within specifications. 

 

 

CyberPower Systems Inc. 

www.cpsww.com 

 

Entire  contents  copyright

©

  2014  CyberPower  Systems  Inc.,  All  rights  reserved.  Reproduction  in  whole  or  in  part 

without permission is prohibited. PowerPanel

®

 Business Edition and PowerPanel

®

 Personal Edition are trademarks of 

CyberPower Systems Inc

 

Model 

OL6KRT2UTFHWIOR 

TAA 

OL6KRT2UTFHWIO 

TAA 

OL10KRT2UTFHWIOR 

TAA 

OL10KRT2UTFHWIO 

TAA 

Configuration 

 

Maximum Output Power (VA)* 

6000VA 

10000VA 

 

Maximum Output Power (W)* 

6000W 

10000W 

 

Form Factor 

Rackmount / Tower 

Input 

 

Nominal Input Voltage 

200/208/220/230/240Vac 

 

Input Voltage Range 

200-240Vac 

 

Input Current Rating 

30A 

50A 

 

Input Frequency 

50/60Hz 

Output

 

 

Nominal Output Voltage 

100/110/115/120Vac or 200/208/220/230/240Vac 

 

UPS Outlets 

(6) 5-20R 

(1) Terminal block 

(1) Terminal block 

(6) 5-20R 

(1) Terminal block 

(1) Terminal block 

Physical 

 

Dimensions 

L x W x H = 23.6 x 17 x 3.46in. (60 x 43.3 x 8.8cm)

 

 

Net Weight 

95.5lbs(43.4Kg)

 

119.7lbs(54.4Kg)

 

Environment

 

 

Operating Temperature 

32

  to 104

  ( 0

  to 40

 

Operating Relative Humidity 

0 to 90% Non-Condensing 

Safety

 

 

Conformance Approvals 

CE, UL, BSMI 

Summary of Contents for OL10KRT2UTFHWIORTAA

Page 1: ...Down Transformer OL6KRT2UTFHWIOTAA OL10KRT2UTFHWIOTAA OL6KRT2UTFHWIORTAA OL10KRT2UTFHWIORTAA CyberPower Systems USA Inc 4241 12th Avenue East Suite 400 Shakopee MN 55379 Phone 877 297 6937 Fax 952 403...

Page 2: ...des the UPS and connected equipment from any outside utility line fluctuations or interference 2U Step Down and Isolation Transformer User s manual Registration card Rackmount left rail Rackmount righ...

Page 3: ...hes deep Select the proper holes in the rack for positioning the Step Down Transformer in the rack The 2U Step Down Transformer takes up position 1 through position 6 The 3U Step Down Transformer take...

Page 4: ...odule Step 3 Attach dust covers Insert dust covers into the rackmount ear screw holes that are not being used SAFETY PRECAUTIONS CAUTION Installation environment should be in a temperature and humidit...

Page 5: ...eck wiring dimensions with the following table Step Down and Isolation Transformers with hardwire Wiring AWG Wiring mm 2 OL6KRT2UTFHWIOTAA OL6KRT2UTFHWIORTAA 10 AWG 5 5 mm 2 OL10KRT2UTFHWIOTAA OL10KRT...

Page 6: ...iguration Insert the input output cables through the appropriate cable gland Hardwire the input output terminals as shown in the following terminal block identification and configuration table Step 4...

Page 7: ...Voltage L1 L2 200Vac L1 N L2 100Vac 0 100Vac L1 L2 200Vac L1 L2 220Vac L1 N L2 110Vac 0 110Vac L1 L2 220Vac L1 L2 230Vac L1 N L2 115Vac 0 115Vac L1 L2 230Vac Input Voltage AC Output Connection Output...

Page 8: ...pyright 2014 CyberPower Systems Inc HARDWIRING THE INPUT OUTPUT TERMINALS 7 POWER CABLE CONNECTION OL6000RT3UTFTAA OL6000RT3UPDUTFTAA OL8000RT3UTFTAA OL10000RT3UTFTAA OL8000RT3UPDUTF OL10000RT3UPDUTFT...

Page 9: ...output terminal block 3 Battery Backup Surge Protected Outlets 120Vac Provides battery backup and surge protection They ensure power is provided to connected equipment over a period of time during a p...

Page 10: ...OL6KRT2UTFHWIOR TAA OL6KRT2UTFHWIO TAA OL10KRT2UTFHWIOR TAA OL10KRT2UTFHWIO TAA Configuration Maximum Output Power VA 6000VA 10000VA Maximum Output Power W 6000W 10000W Form Factor Rackmount Tower In...

Page 11: ...ber the Purchase Date and each item of Connected Equipment 2 Email us at tech cpsww com or Call us at 877 297 6937 3 If your product requires warranty service you must provide a copy of your dated pur...

Page 12: ...1 Loss of or damage to data records or software or the restoration of data or records or the reinstallation of software 2 Damage from causes other than AC Power Line Transients spikes or surges on pro...

Page 13: ...interference in which case the user will be required to correct the interference at his own expense Shielded signal cables must be used with this product to ensure compliance with the Class A FCC lim...

Reviews: