CyberPower CST150XLU User Manual Download Page 4

INSTALLING YOUR UPS SYSTEM - continued 

the unit will emit one long beep. To correct 

this, turn the UPS of and unplug at least 

one piece of equipment from the battery 

power supplied outlets. Make sure the 

circuit breaker is depressed and then turn 

the UPS on. 

8. To store the UPS for an extended period,

cover it and store with the battery fully

charged. While in storage, recharge the

battery every three months to ensure

battery life.

9. Ensure the wall outlet and UPS are located

7. To maintain optimal battery charge,

leave the UPS plugged into an AC outlet

at all times.

near the equipment being attached for

proper accessibility. near the equipment

being attached for proper accessibility.

BASIC OPERATION 

1. Power Switch

Used as the master on/of switch for

equipment connected to the battery

power supplied outlets. (Please refer

to the Function Setup Guide for more

information.)

2. Power On Indicator

This LED is illuminated when the utility

power is normal and the UPS outlets are

providing power, free of surges and spikes.

3. LCD module display

The LCD display shows all the UPS

information using icons and messages.

For more information please review the

“Defnitions for Illuminated LCD Indicators”

section below.

4. LCD Display Toggle/Selected Switch

The switch can be used to select the LCD

display contents including Input Voltage,

Output Voltage, and Estimated Run Time.

The toggle frequency is set to one time

per second.

5. USB Charging Ports

The USB Charging ports provide 5V 2.1A

power output.

6. Battery and Surge Protected Outlets

The UPS has fve battery powered/

surge suppression outlets for connected

equipment to ensure temporary

uninterrupted operation of your equipment

during a power failure. (DO NOT plug a

laser printer, paper shredder, copier, space

heater, vacuum, sump pump or other

large electrical devices into the “Battery

and Surge Protected Outlets”. The power

demands of these devices may overload

and damage the unit.)

7. Full-Time Surge Protection Outlets

The UPS has fve surge suppression outlets.

8. Circuit Breaker

Located on the back of the UPS, the circuit

breaker serves to provide overload and

fault protection.

9. USB Ports to PC

The USB port allows connection and

communication between the USB port on

the computer and the UPS unit.

10.Communication Protection Ports 

Communication protection ports will 

protect any standard modem, fax, 

telephone line, network or Ethernet 

connection (RJ11/RJ45). 

11. Wiring Fault Indicator (red)

This LED indicator will illuminate to warn

the user that a wiring problem exists, such

as bad ground, missing ground or reversed

wiring. If this is illuminated, disconnect

all electrical equipment from the outlet

and have an electrician verify the outlet is

properly wired. The UPS will not provide

surge protection without being plugged

into a grounded and properly wired wall

outlet.

12.Coax/Cable/DSS Surge Protection

The Coax/Cable/DSS protection ports will

protect any cable modem, CATV converter,

or DSS receiver.

13. Outlets Designed for AC Adapters

The unit has two outlets spaced to allow

AC power adapter blocks to be plugged

into the UPS without blocking adjacent

outlets.

Summary of Contents for CST150XLU

Page 1: ...harging Ports 6 Battery and Surge Protected Outlets 7 Full Time Surge Protection Outlets 8 Circuit Breaker 9 USB Ports to PC 10 Communication Protection Ports 11 Wiring Fault Indicator red 12 Coax Cable DSS Surge Protection 13 Widely Spaced Outlets Designed for AC Adapters Cyber Power Systems USA Inc 4241 12th Avenue East Suite 400 Shakopee MN 55379 CyberPowerSystems com ...

Page 2: ...ircuit breaker protection Do not plug into an outlet that is not grounded If you need to de energize this equipment turn of and unplug the unit CAUTION To avoid electric shock turn of the unit and unplug it from the AC power source before connecting equipment to the unit CAUTION To reduce the risk of fre connect only to a circuit provided with 20 amperes maximum branch circuit over current protect...

Page 3: ...tem performance keep the load below 80 of the unit s rated capacity HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt However after receiving a new UPS to ensure the battery s maximum charge capacity it is recommended that you charge the battery for at least 8 hours Your UPS is equipped with an auto charge feature When the UPS is plugged into an AC outlet the battery ...

Page 4: ...ports provide 5V 2 1A power output 6 Battery and Surge Protected Outlets The UPS has fve battery powered surge suppression outlets for connected equipment to ensure temporary uninterrupted operation of your equipment during a power failure DO NOT plug a laser printer paper shredder copier space heater vacuum sump pump or other large electrical devices into the Battery and Surge Protected Outlets T...

Page 5: ...lug it from the AC power source 3 Turn the UPS on its side 4 Remove two retaining screws located on the bottom of the UPS 5 Slide the battery compartment cover completely of of the unit 6 Remove the battery which is located on the right side from the compartment 7 Disconnect the battery wires from the right side of the battery 8 Slide the remaining battery from left to right and remove it from the...

Page 6: ...erpowersystems com support Mechanical problem Contact CyberPower Systems at cyberpowersystems com support The USB cable is not connected Connect the USB cable to the UPS unit and an open USB port on the back of the computer You must use the cable that came with the unit PowerPanel Personal is inactive all icons are gray The USB cable is connected to the wrong port Check the back of the computer fo...

Page 7: ...c Voltage Regulation Icon This icon appears whenever your UPS is automatically correcting low AC line voltage without using battery power This is a normal automatic operation of your UPS and no action is required on your part 7 SILENT MODE Icon This icon appears whenever the UPS is in silent mode The buzzer does not beep during silent mode until the battery reaches low capacity The LCD display ind...

Page 8: ...ets 12 Amps On Battery Output Wave Form Simulated Sinewave Operating Temperature 32 F to 104 F 0 C to 40 C Operating Relative Humidity 0 to 95 non condensing Size W x H x D 3 9 in 9 8 in 13 7 in Net Weight 25 0 lbs 11 3 kg Battery Type CyberPower RB1290X2 Typical Battery Recharge Time 8 hours to 90 capacity from total discharge Typical Battery Life 3 to 6 years depending on number of discharge rec...

Page 9: ...the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment to an outlet on a circuit diferent from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Warning Changes or modifcations...

Reviews: