CyberPower CST150XLU User Manual Download Page 3

INSTALLING YOUR UPS SYSTEM 

UNPACKING 

Inspect the UPS upon receipt. 

The box should contain the following: 
(a) UPS unit

(b) User’s manual

(c) USB A + B type cable

(d) Function Setup Guide
PowerPanel® software is available on our website. 

Please visit www.cyberpowersystems.com and 

go to the Software Section for a free download. 

OVERVIEW 

The CST150XLU provides complete power 

protection from utility power that is not always 

consistent. The CST150XLU features 1500 

Joules of surge protection. The unit provides 

long lasting battery backup during power 

outages with maintenance free batteries. The 

CST150XLU ensures consistent power to your 

computer system and includes software that 

will automatically save your open fles and 

shutdown your computer system during a 

utility power loss. 

AUTOMATIC VOLTAGE REGULATOR 

The CST150XLU stabilizes inconsistent utility 

power voltage to nominal 

levels that are safe for 

equipment. Inconsistent 

incoming utility power 

may be damaging to 

important data fles 

and hardware, but with 

Automatic Voltage 

Regulation (AVR), 

damaging voltage levels are corrected to safe 

levels. AVR automatically increases low utility 

power or decreases high utility power to a 

consistent and safe 110/120 volts. 

DETERMINE THE POWER REQUIREMENTS 

OF YOUR EQUIPMENT 

1. Ensure that the equipment plugged into

the UPS does not exceed the UPS unit’s

rated capacity. If the rated capacities of the

unit are exceeded, an overload condition

may occur and cause the UPS unit to shut

down or the circuit breaker to trip.

2. There are many factors that can afect

the amount of power that your electronic

equipment will require. For optimal system

performance keep the load below 80% of

the unit’s rated capacity.

HARDWARE INSTALLATION GUIDE 

1. Your new UPS may be used immediately

upon receipt. However, after receiving a

new UPS, to ensure the battery’s maximum

charge capacity, it is recommended that

you charge the battery for at least 8 hours.

Your UPS is equipped with an auto-charge

feature. When the

UPS is plugged

into an AC outlet,

the battery will

automatically charge

whether the UPS is

turned on or of.

2. Note: This UPS is designed with a safety

feature to keep the system from being

turned on during shipment. The frst time

you turn the UPS on, you will need to have

it connected to AC power or it will not

power up.

3. With the UPS unit turned of and

unplugged, connect your computer,

monitor, and any other peripherals

requiring battery backup into the battery

power supplied outlets. 

DO NOT plug a

laser printer, paper shredder, copier, space

heater, vacuum, sump pump or other

large electrical devices into the “Battery

and Surge Protected Outlets”. The power

demands of these devices may overload

and damage the UPS.

4. To protect a fax, phone

or modem, connect a

telephone cable or network

cable from the wall jack

outlet to the IN jack of the UPS. Connect

a telephone cable or network cable from

the OUT jack of the UPS to a fax machine,

telephone, modem, or network devices.

5. Plug the UPS into a 2-pole,

3-wire grounded receptacle

(wall outlet). Make sure

the wall branch outlet

is protected by a fuse

or circuit breaker and does not service

equipment with large electrical demands

(e.g. air conditioner, copier, etc.). The

warranty prohibits the use of extension

cords, outlet strips, and surge strips.

6. Press the power switch to turn the unit on.

The Power On indicator light will illuminate

and the unit will “beep”. If an overload is

detected, an audible alarm will sound and

-

continued

Summary of Contents for CST150XLU

Page 1: ...harging Ports 6 Battery and Surge Protected Outlets 7 Full Time Surge Protection Outlets 8 Circuit Breaker 9 USB Ports to PC 10 Communication Protection Ports 11 Wiring Fault Indicator red 12 Coax Cable DSS Surge Protection 13 Widely Spaced Outlets Designed for AC Adapters Cyber Power Systems USA Inc 4241 12th Avenue East Suite 400 Shakopee MN 55379 CyberPowerSystems com ...

Page 2: ...ircuit breaker protection Do not plug into an outlet that is not grounded If you need to de energize this equipment turn of and unplug the unit CAUTION To avoid electric shock turn of the unit and unplug it from the AC power source before connecting equipment to the unit CAUTION To reduce the risk of fre connect only to a circuit provided with 20 amperes maximum branch circuit over current protect...

Page 3: ...tem performance keep the load below 80 of the unit s rated capacity HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt However after receiving a new UPS to ensure the battery s maximum charge capacity it is recommended that you charge the battery for at least 8 hours Your UPS is equipped with an auto charge feature When the UPS is plugged into an AC outlet the battery ...

Page 4: ...ports provide 5V 2 1A power output 6 Battery and Surge Protected Outlets The UPS has fve battery powered surge suppression outlets for connected equipment to ensure temporary uninterrupted operation of your equipment during a power failure DO NOT plug a laser printer paper shredder copier space heater vacuum sump pump or other large electrical devices into the Battery and Surge Protected Outlets T...

Page 5: ...lug it from the AC power source 3 Turn the UPS on its side 4 Remove two retaining screws located on the bottom of the UPS 5 Slide the battery compartment cover completely of of the unit 6 Remove the battery which is located on the right side from the compartment 7 Disconnect the battery wires from the right side of the battery 8 Slide the remaining battery from left to right and remove it from the...

Page 6: ...erpowersystems com support Mechanical problem Contact CyberPower Systems at cyberpowersystems com support The USB cable is not connected Connect the USB cable to the UPS unit and an open USB port on the back of the computer You must use the cable that came with the unit PowerPanel Personal is inactive all icons are gray The USB cable is connected to the wrong port Check the back of the computer fo...

Page 7: ...c Voltage Regulation Icon This icon appears whenever your UPS is automatically correcting low AC line voltage without using battery power This is a normal automatic operation of your UPS and no action is required on your part 7 SILENT MODE Icon This icon appears whenever the UPS is in silent mode The buzzer does not beep during silent mode until the battery reaches low capacity The LCD display ind...

Page 8: ...ets 12 Amps On Battery Output Wave Form Simulated Sinewave Operating Temperature 32 F to 104 F 0 C to 40 C Operating Relative Humidity 0 to 95 non condensing Size W x H x D 3 9 in 9 8 in 13 7 in Net Weight 25 0 lbs 11 3 kg Battery Type CyberPower RB1290X2 Typical Battery Recharge Time 8 hours to 90 capacity from total discharge Typical Battery Life 3 to 6 years depending on number of discharge rec...

Page 9: ...the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment to an outlet on a circuit diferent from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Warning Changes or modifcations...

Reviews: