Operations Guide
931475A
CyberData Corporation
Installing the SIP Weatherproof Keypad Phone
Setting up the Device
39
Note
You must click on the
Save
button and then the
Reboot
button for the changes to take
effect.
Note
For specific server configurations, go to the following website address:
http://www.cyberdata.net/connecting-to-ip-pbx-servers/
RTP Settings
RTP Port (even)
Specify the port number used for the RTP stream after establishing a
SIP call. This port number must be an even number and defaults to
10500. The supported range is 0-65536. Enter up to 5 digits.
Jitter Buffer
Specify the size of the jitter buffer (in milliseconds) used for SIP calls.
Valid values are 50-1000.
Click the
Save
button to save your configuration settings.
Note
: You need to reboot for changes to take effect.
Click on the
Reboot
button to reboot the system.
Click on the
Toggle Help
button to see a short description of some of
the web page items. First click on the
Toggle Help
button, and you will
see a question mark (
) appear next to some of the web page items.
Move the mouse pointer to hover over a question mark to see a short
description of a specific web page item.
Table 2-11. SIP Configuration Parameters (continued)
Web Page Item
Description