TECHNICAL SPECIFICATIONS
Model
OR500LCDRM1Ua
OR700LCDRM1Ua
Capacity
500VA / 300W
700VA / 400W
Nominal Input Voltage
90 Vac to 140 Vac
Input Frequency
60 Hz ± 3 Hz (Auto-sensing)
AVR Function
Yes
On-Battery Output Voltage
120Vac ± 5%
On-Battery Output
Wave Form
Simulated Sine Wave Form
Operating Temperature
+ 32°F to 104° F / 0° C to 40° C
Operating Relative Humidity
0 to 90% NON-CONDENSING
Size (W x H x D)
433 x 235 x 44 mm (1U Rack) / 17.05 x 9.25 x 1.75 in.
Net Weight
16.5 lbs / 7.47 kg
17.3 lbs / 7.83 kg
Battery Type
CyberPower / RB0670X2
CyberPower / RB0690X2
Typical Battery
Recharge Time
8 hours
Typical Battery Life
3 to 6 years, depending on number of discharge/recharge cycles
Recommended Battery
Sealed Maintenance Free Lead Acid Battery
Safety Approvals
UL1778 4th, cUL CSA C22.2 No.107.3-05, FCC/DoC Class B
SYSTEM FUNCTION BLOCK DIAGRAM
Input
Output
Battery Mode
Normal Mode
EMI
Filter
Surge
Suppressor
Inverter
Charger
AC / DC
Battery
AVR