Thank you for purchasing a CyberPower product.  This UPS is designed to provide unsurpassed 

power protection, operation, and performance during the lifetime of the product. Please take a 

few minutes to register your product at: 

www.CyberPowerSystems.com/registration

.  

Registration certifies your product’s warranty, confirms your ownership in the event of a 

product loss or theft, and entitles you to free technical support. Register your product now to 

receive the benefits of CyberPower ownership.

CAUTION! 

 To prevent the risk of fire or  

electric shock, install in a temperature and 

humidity controlled indoor area free of  

conductive contaminants. (Please see  

specifications for acceptable temperature  

and humidity range). 

CAUTION!

 To reduce the risk of electric shock, 

do not remove the cover except to service the 

battery. Turn off and unplug the unit before

servicing the batteries. There are no user 

serviceable parts inside except for the battery.

CAUTION!

 Hazardous live parts inside can be 

energized by the battery even when the AC 

input power is disconnected.

CAUTION!

 The UPS must be connected to an 

AC power outlet with fuse or circuit breaker 

protection. Do not plug into an outlet that is 

not grounded. If you need to de-energize this 

equipment, turn off and unplug the unit.

CAUTION!

 To avoid electric shock, turn off the 

unit and unplug it from the AC power source 

before installing a computer component.

CAUTION!

 To reduce the risk of fire, connect 

only to a circuit provided with 20 amperes 

maximum branch circuit over current 

protection in accordance with the National 

Electric Code, ANSI/NFPA 70.

CAUTION!

 Not for use in a computer room 

as defined in the Standard for the Protection 

of Electronic Computer/Data Processing 

Equipment, ANSI/NFPA 75.

CAUTION!

 Do not dispose of batteries in a 

fire. The batteries may explode.

CAUTION!

 Do not open or mutilate batteries. 

Released electrolyte is harmful to the skin and 

eyes. It may be toxic.

DO NOT USE FOR MEDICAL  

OR LIFE SUPPORT EQUIPMENT!

  

CyberPower Systems does not sell products 

for life support or medical applications. DO 

NOT use in any circumstance that would 

affect operation and safety of life support 

equipment, any medical applications or 

patient care.

DO NOT USE WITH OR NEAR AQUARIUMS!

  

To reduce the risk of fire or electric shock, 

do not use with or near an aquarium. 

Condensation from the aquarium can cause 

the unit to short out.

DO NOT USE THE UPS  

ON ANY TRANSPORTATION!

  

To reduce the risk of fire or electric shock, do 

not use the unit on any transportation such 

as airplanes or ships. The effect of shock or 

vibration caused during transit and the damp 

environment can cause the unit to short out.

PRODUCT REGISTRATION

IMPORTANT SAFETY WARNINGS 

(SAVE THESE INSTRUCTIONS)

This manual contains important safety instructions. Please read and follow all instructions carefully 

during installation and operation of the unit. Read this manual thoroughly before attempting to 

unpack, install, or operate your UPS.

Summary of Contents for OR500LCDRM1U

Page 1: ...379 CyberPowerSystems com FEATURES 1 LCD Module Display 2 Power On Indicator 3 Power Switch 4 LCD Function Selected Switch 5 Battery and Surge Protected Outlets 6 Full Time Surge Protection Outlets 7 SNMP HTTP Network Slot 8 Communication Protection Ports RJ45 9 USB Port to PC 10 Dry Contact 11 Circuit Breaker 12 AC Input 13 Electrical Wiring Fault Indicator Red ...

Page 2: ...lling a computer component CAUTION To reduce the risk of fire connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in accordance with the National Electric Code ANSI NFPA 70 CAUTION Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer Data Processing Equipment ANSI NFPA 75 CAUTION Do not dispose of batterie...

Page 3: ...or the circuit breaker to trip 2 There are many factors that can affect the amount of power that your electronic equipment will require For optimal system performance keep the load below 80 of the unit s rated capacity HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt However after receiving a new UPS to ensure the battery s maximum charge capacity it is recommended t...

Page 4: ...re DO NOT plug a laser printer paper shredder copier space heater vacuum cleaner sump pump or other large electrical devices into the Battery and Surge Protected Outlets The power demands of these devices may overload and damage the unit 6 Full Time Surge Protection Outlets The unit has two surge suppression outlets 7 SNMP HTTP Network Slot Remove the cover panel to install an optional RMCARD prov...

Page 5: ... 1 Remove all watches rings or other metal objects 2 Only use tools with insulated handles 3 DO NOT lay tools or other metal parts on top of battery or any battery terminals 4 Wear rubber gloves and boots 5 Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground CONTACT WITH A GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK The likelihood of such shock ...

Page 6: ...V 3rd V X X X V V 4th V X X V X V 5th Return V X X V X V Overload V X V Select SW Press UPS Status Display Capacity Display Digital Value Display Load Cap Battery Cap Input Voltage Output Voltage of Load of Batt Run Time Initial X V X X V V 1st X V X X V V 2nd X V X V X V 3rd X V X X V V 4th X V X X V V 5th Return X V X X V V Overload X V V Line Mode Battery Mode V Illuminated X Not Illuminated Ei...

Page 7: ...t CyberPower Systems about replacement batteries at cyberpowersystems com support The UPS will not turn on The on off switch is designed to prevent damage from rapidly turning it off and on Turn the UPS off Wait 10 seconds and then turn the UPS on The battery is worn out Contact CyberPower Systems about replacement batteries at cyberpowersystems com support Mechanical problem Contact CyberPower Sy...

Page 8: ...NON CONDENSING Size W x H x D 433 x 235 x 44 mm 1U Rack 17 05 x 9 25 x 1 75 in Net Weight 16 5 lbs 7 47 kg 17 3 lbs 7 83 kg Battery Type CyberPower RB0670X2 CyberPower RB0690X2 Typical Battery Recharge Time 8 hours Typical Battery Life 3 to 6 years depending on number of discharge recharge cycles Recommended Battery Sealed Maintenance Free Lead Acid Battery Safety Approvals UL1778 4th cUL CSA C22 ...

Page 9: ...ur state This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of ...