background image

EN

5

Technical Information

Rated voltage: 

24 V =

Rated input:

4.3 W

Voltage supply:

100-240 V~ (50/60 Hz)

Impulse cables:

2 x 3 m 

Output:

2 x capacitive

Dimensions (H/W/D):

180 x 150 x 50 mm

Max. pipe-Ø: 

"

 (40mm)

Safety instructions

Attention: Please read the instruction manual before  
installing and starting up the system! 

To avoid causing damage, please follow these safety 
instructions:
-  Connect calmat

®

 only to a correct and firmly installed 

earthed safety socket (100–240 V~, 50/60 Hz).

-  Do not disconnect from power by pulling the wire. 

Always disconnect pulling the plug.

-  Do not open the electronic unit.
-  The exterior temperature where the unit is installed 

should be between -10° C until max. +55° C. 

-  The power plug should be kept away from water drops 

and water spray.

-  Please clean the unit with a damp cloth only (no 

detergents).

-  Protect calmat

®

 from direct humidity, water and direct 

solar radiation.

Installation instructions

The unit is installed on the main water supply (e.g. close to 
the water meter) according to the following instructions: 
-  The electronic control unit can be attached directly on 

to the pipe. This can be done either horizontally and 
vertically. It may also be placed on the wall.

-  Wind the impulse cable tightly and firmly without gaps 

around the pipe. 

-  The impulse cable can also be wound on thicker 

connecting pieces (e. g. pipe collars, pipe reducers, 
compression couplings etc.).

-  Before the installation, casing or insulating material on 

the pipe must be removed. Thin coats of paint can be left.

-  Fe: The iron and metal concentration in the water 

should not exceed 1 mg/l (1 ppm)

-  Mn: The manganese level should not exceed 0.1 mg/l 

(0.1 ppm)

-  Boilers and heaters: calmat® works best for systems 

with heating elements surface temperatures of max 
207°F/97°C. 

Installation

1)

 Place calmat

®

 on the pipe. Install calmat

®

 on the main 

water pipe and fix the electronic unit with the cable ties.

2)

 Now place the red impulse cable in the left socket (4). 

Feed the cable to the back of the pipe and fasten with a 
cable tie. Wind the cable tightly and firmly around the 
pipe to create a coil. Plug the second impulse tie through 
the black loop at the end of the cable and fasten it. 

3)

 Repeat the installation with the second impulse cable 

again (see 2.).

4)

 First connect the adaptor (5) with the electronic unit 

with the socket on the left site of the device. Plug the 
mains plug into the power socket (permissible voltage: 
100 - 240 V, 50/60 Hz). The green control light (3) will light 
up. The display will show: calmat 

5)

  Set up your program: Please choose your language with 

the upper button ( ). Then press the button (P) to select the 
program according to your pipe material and pipe diameter 
(a,b,c, or d). You can change the programme selection at any 
time later. 

2a

Metal pipe

Ø max 1

"

2b

Metal pipe 

Ø max 1 ½

"

2c

Plastic pipe 

Ø max 1

"

2d

Plastic pipe

Ø max 1 ½

"

Final check

The electricity supply is indicated by the green control 
light (3). The display shows the activated program.

CONTENTS

Electronic unit 

 

1

 Power adapter

Impulse cable 

 

8

 Cable binders 

Instruction manual   

(6 + 2 extra) 

1

 Warranty card 

CWT hereby declares that this product is in accordance with the follow-

ing EU-guidelines: 73/23/EG; 89/336/EG which is certified by the CE-

mark. The equipment corresponds to the requirements of the German  

Industrial Safety Act and the European low-voltage guidelines. This is certi-

fied by the GS-mark of the independent testing institute.

Summary of Contents for calmat 1431218

Page 1: ......

Page 2: ......

Page 3: ...3 calmat calmat min 1 2 calmat calmat Installation Examples...

Page 4: ...um crystals form into arod likestructure 2 Inthisform theycannolongerattach to each other or build deposits The harmless crystal rods are held in suspension in the water In this form they will be wash...

Page 5: ...vel should not exceed 0 1 mg l 0 1 ppm Boilers and heaters calmat works best for systems with heating elements surface temperatures of max 207 F 97 C Installation 1 Place calmat on the pipe Install ca...

Page 6: ...paration on reux d un technicien deviennent alors in vitables La technologie cologique calmat Ce convertisseur calcaire et rouille est un appareil de traitement physique de l eau Dans une eau non trai...

Page 7: ...ieure ne doit pas descendre au dessous de 10 C ni d passer 55 C max La fiche doit tre tenue l abri de l humidit et des projections d eau Nettoyer l unit l aide d un chiffon humide sans d tergents Prot...

Page 8: ...n tout moment 3a Tuyau en m tal max 1 3b Tuyau en m tal max 1 3c Tuyau en plastic max 1 3d Tuyau en plastic max 1 Contr le final L alimentation lectrique est indiqu e par le voyant de contr le vert 3...

Page 9: ...aparatos el ctricos A causa de la cal las tuber as se obstruven completamente hasta tener que ser reemplazadas Las reparaciones caras del t cnico son entonces inevitables La tecnolog a ecol gica de ca...

Page 10: ...instrucciones detenida mente antes de iniciar el montaje y la puesta en funcionamiento de la unidad Por favor para evitar da os siga las instrucciones de seguridad S lo puede conectarse a un enchufe a...

Page 11: ...z de control 3 verde En la pantalla podr leer calmat 5 Programar Por favor elija con la primer tecla su idioma Despu s marca con la tecla P el mejor programa para su material y di metro de tubo Despu...

Page 12: ...USA CA 05 2016 Christiani Wassertechnik GmbH Berlin Germany calmat usa com...

Reviews: